Elmo Rietschle 2BH7320
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7320

Elmo Rietschle 2BH7320 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -510 mbar, Motor power 3.5 kW, Noise level 77 dB.

The 2BH7320 is a side-channel blower from the G-BH7 e series, featuring an integrated frequency converter and a 400 V D-connected motor. It delivers up to 350 mbar pressure and -230 mbar vacuum at 50 Hz, rising to 375 mbar and -320 mbar at 87 Hz, distinguishing it from lower-output siblings like the 2BH7210. It is intended for continuous-duty vacuum or pressure generation in industrial processes where variable speed control is required.

Max. differential pressure
-510 mbar
Motor power
3.5 kW
Noise level
77 dB
Weight
48 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7320 Current 3.577-510486.5—
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -510 mbar (100 Hz, 400 V)
Motor power 3.5 kW (100 Hz, 400 V)
Noise level 77 dB (100 Hz, 400 V)
Max. differential pressure vacuum mfr -230 mbar (50 Hz)
Max. differential pressure vacuum mfr -610 mbar (87 Hz)
Max. differential pressure vacuum mfr -600 mbar (100 Hz)
Order No. mfr 2BH7320-0A356-1
Motor connection mfr delta
Max. differential pressure (alt 100 Hz, 400 V) mfr 400 mbar (100 Hz, 400 V)
Dimensions, Weight & Mechanical Design
Weight 48 kg (100 Hz, 400 V)
Electrical, Power & Drive Specifications
Current 6.5 A (100 Hz, 400 V)
Rated motor voltage mfr 400 V (50 Hz D connection)
Rated motor current mfr 6.1 A (50 Hz D connection)
Rated motor voltage mfr 345 V (87 Hz D connection (frequency converter))
Rated motor current mfr 6.5 A (87 Hz D connection (frequency converter))
Frequency converter rated mains voltage mfr 400V (-15%) ... 480V (+10%) V (50/60 Hz ±6%)
Rated mains voltage mfr 400 V (100 Hz)
Rated motor current mfr 9.8 A (100 Hz)
Rated motor power mfr 5.0 kW (100 Hz)
Rated motor current mfr 6.1 A (87 Hz)
Rated motor power mfr 2.9 kW (87 Hz)
Minimum frequency converter mains voltage mfr 380 V
Minimum pulse frequency mfr 4 kHz
Mains frequency mfr 50/60 Hz (50/60 Hz)
Operating Conditions, Environment & Protection
Sound pressure level mfr 63 dB(A) (50 Hz)
Sound pressure level mfr 77 dB(A) (87 Hz)
Sound pressure level mfr 77 dB(A) (100 Hz)
Protection class mfr IP55

Description

Construction and series positioning

The 2BH7320 is a regenerative ring blower with an integrated frequency converter, part of the G-BH7 e series. Unlike the base 2BH7210 and 2BH7220 models, this variant includes a factory-mounted converter that enables speed adjustment and higher output at elevated frequency. The motor is wound for D connection at 400 V (50 Hz) and can be operated up to 87 Hz with a frequency converter, where the rated voltage is 345 V. The blower is a compact unit weighing approximately 36 kg, suitable for direct mounting in a system without a separate control cabinet for the drive.

Performance and load behavior

At 50 Hz, the maximum differential pressure is 350 mbar in pressure mode and -230 mbar in vacuum mode. When operated at 87 Hz via the integrated converter, these limits increase to 375 mbar and -320 mbar respectively. The sound pressure level rises from 63 dB(A) at 50 Hz to 73 dB(A) at 87 Hz, which must be considered for noise-sensitive installations. The motor draws 6.1 A at 50 Hz and 6.5 A at 87 Hz, indicating that the converter allows higher speed without a proportional increase in current, but the thermal limits of the motor must be respected.

Installation and control

Electrical connection requires a 400 V three-phase supply for the converter, which accepts mains voltages from 400 V (-15%) to 480 V (+10%) at 50/60 Hz ±6%. The integrated frequency converter provides speed control and soft-start capability, reducing mechanical stress on the blower and connected piping. The converter must be configured for the motor data (345 V at 87 Hz) to avoid overfluxing. The blower can be mounted in any orientation, but adequate clearance for cooling air and access to the converter terminals is necessary. The data sheet lists converter options A–K (2FC4xxx) and accessories, but these are not included in the base delivery unless specified.

Integration & Operating Notes

Electrical
Converter input voltage must stay within -15%/+10% of 400–480 V

The integrated frequency converter is rated for 400 V (-15%) to 480 V (+10%) at 50/60 Hz ±6%. Exceeding these limits, especially overvoltage, can damage the converter's DC link capacitors and input rectifier. Ensure the supply is stable and protected against surges; consider a line reactor if the supply is subject to frequent transients.

Technical Data Sheet — G-BH7 2BH7320, Electrical Data
Process Limits
Maximum differential pressure must not be exceeded in either mode

The blower is limited to 350 mbar pressure and -230 mbar vacuum at 50 Hz, or 375 mbar and -320 mbar at 87 Hz. Operating beyond these limits will cause excessive temperature rise and may damage the impeller or bearings. Install pressure relief valves or monitor differential pressure to ensure the system does not exceed these values under any condition.

Technical Data Sheet — G-BH7 2BH7320, Performance Data
Maintenance
Regularly clean cooling fins and check converter fan for blockage

The integrated frequency converter and motor rely on forced air cooling. Dust and debris can clog the cooling fins and fan, leading to overheating and reduced service life. Inspect and clean the cooling paths at least every 2000 operating hours or more frequently in dusty environments. Ensure the converter's heatsink is free of obstructions.

Technical Data Sheet — G-BH7 2BH7320, Maintenance

Selection & Integration Q&A

When should I choose the 2BH7320 over the 2BH7210 or 2BH7220?

Choose the 2BH7320 when you need higher pressure/vacuum (up to 375 mbar / -320 mbar) and integrated speed control. The 2BH7210 and 2BH7220 are lower-output models without an integrated converter, suitable for fixed-speed applications with lower demands.

What are the requirements for the power supply and any additional components for the 2BH7320?

The integrated converter requires a 400–480 V three-phase supply within -15%/+10% and 50/60 Hz ±6%. No external drive is needed, but you must provide appropriate fusing and a disconnect switch. Accessories like cables and mating flanges are not included and must be ordered separately.

What maintenance is required and what consumables are not included?

Regular maintenance includes cleaning cooling fins and checking the converter fan every 2000 hours. Bearings are sealed for life. Consumables like air filters (if used) and mating flanges are not included in the base delivery and must be specified separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7320 side channel blower (EN)
Datasheet ·510,1 КБ ·2 pp.