Elmo Rietschle 2BH722
Elmo Rietschle 2BH722 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 490 mbar, Motor power 1 kW, Noise level 63 dB.
The 2BH722 is a side-channel (regenerative ring) blower from Elmo Rietschle's G-BH7 series, driven by a 2.0 kW IE3-class motor in IP55 protection. It delivers up to 480 mbar differential pressure in either vacuum or pressure mode at both 50 and 60 Hz, distinguishing it from lower-capacity siblings such as the 2BH721. Its primary role is to provide oil-free, pulsation-free air for vacuum holding, pneumatic conveying, or low-pressure aeration in industrial systems.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH722 Current | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | 490 mbar (50 Hz) 60 Hz: 480 mbar |
| Motor power | 1.0 kW (50 Hz) 60 Hz: 1.1 kW |
| Noise level | 58 dB(A) (50 Hz) 60 Hz: 63 dB(A) |
| Ultimate pressure | -370 mbar (50 Hz) 60 Hz: -480 mbar |
| Max. differential pressure (vacuum) mfr | -480 mbar (50 Hz) |
| Max. differential pressure (vacuum) mfr | -480 mbar (60 Hz) |
| Order No. mfr | 2BH7220-0AK31-1 |
| Max. differential pressure vacuum mfr | -370 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -480 mbar (60 Hz) |
| Weight | 28 kg |
| Current | 4.2 A (50 Hz) 60 Hz: 4.8 UU / 2.4 U A |
| Frequency | 50/60 Hz |
| Voltage | 190-210 D V (50 Hz) 60 Hz: 190-210 UU / 380-420 U V |
| Efficiency class mfr | IE3 (50 Hz) |
| Rated voltage mfr | 200 UU V (60 Hz) |
| Rated current mfr | 4.8 UU A (60 Hz) |
| Rated power mfr | 1.1 kW (60 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Voltage (alt 60 Hz) mfr | 200 UU V (60 Hz) |
| Current (alt 60 Hz) mfr | 4.8 UU A (60 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 58 dB(A) (50 Hz) |
| Sound pressure level mfr | 63 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH722 uses a non-contacting impeller running in a ring-shaped channel; the motor shaft is directly coupled to the impeller, eliminating belts and gears.
- Within the G-BH7 series, this model sits above the 2BH721 and 2BH7210 in pressure capability, while the 2BH731 offers higher capacity. The 2BH722 is the mid-range choice when 480 mbar differential is required without the larger footprint of the 2BH731.
- The motor is a 1.1 kW (60 Hz) / 1.0 kW (50 Hz) IE3 efficiency class unit, wound for dual voltage: 380–420 V Δ / 690 V Y at 50 Hz and 460 V Δ at 60 Hz. Protection is IP55, insulation class F.
Behavior under load and media
- The blower is designed for continuous duty with oil-free air; the side-channel principle produces a non-pulsating flow, but the compression is not isentropic—temperature rise occurs. The maximum differential pressure is 480 mbar at 60 Hz and 490 mbar at 50 Hz; in vacuum mode the ultimate pressure is -480 mbar at 60 Hz and -370 mbar at 50 Hz.
- No digitized curve points are available in the supplied facts; performance at intermediate pressures must be taken from the manufacturer's performance curves for the 2BH722 model (order number 2BH7220-0AK31-1).
- The sound pressure level is 63 dB(A) at 60 Hz and 58 dB(A) at 50 Hz, measured under standard conditions; this is a moderate noise level for a unit of this size, but installation in a confined space may require additional attenuation.
Installation, connection, and control
- The blower is typically mounted horizontally on a rigid base; the motor is foot-mounted. The PDF digest does not provide detailed installation instructions, but the IP55 rating allows outdoor use with protection against dust and water jets.
- Electrical connection must be made according to the voltage and current ratings: at 50 Hz, 3.5 A in delta or 1.7 A in star; at 60 Hz, 1.8 A. The IE3 motor requires a suitable motor protection switch or VFD with correct settings.
- The blower can be operated in either vacuum or pressure mode by connecting the inlet or outlet to the process; the direction of rotation must be checked before startup to avoid reverse flow.
Integration & Operating Notes
The 1.1 kW (60 Hz) / 1.0 kW (50 Hz) IE3 motor draws 3.5 A per phase in delta and 1.7 A in star at 50 Hz, and 1.8 A at 60 Hz. A thermal overload relay or VFD must be configured to these currents to prevent winding damage from sustained overload, especially during cold starts or if the blower is operated near its maximum differential pressure.
The blower is rated for a maximum differential pressure of 480 mbar at 60 Hz and 490 mbar at 50 Hz in both vacuum and pressure operation. Exceeding this limit will cause excessive temperature rise and may lead to impeller rubbing or motor overload. A pressure relief valve or bypass should be installed if the process can generate higher differentials.
Selection & Integration Q&A
Choose the 2BH722 when you need up to 480 mbar differential pressure at 60 Hz (490 mbar at 50 Hz) with a 1.1 kW (60 Hz) / 1.0 kW (50 Hz) IE3 motor. The 2BH721 offers lower pressure at similar power, while the 2BH731 provides higher flow but larger size. The 2BH722 is the mid-range compromise for vacuum or pressure duty.
The motor is dual-voltage: 380–420 V Δ / 690 V Y at 50 Hz, or 460 V Δ at 60 Hz. Use a motor protection switch set to 3.5 A (Δ) or 1.7 A (Y) at 50 Hz, or 1.8 A at 60 Hz. For VFD operation, ensure the drive is rated for the motor current and set the V/f curve to avoid overfluxing at low speeds.
Yes, the IP55 rating allows outdoor installation, but the blower should be shielded from direct rain to prevent water ingress into the inlet/outlet. It is designed for continuous duty (S1) at ambient temperatures up to 40°C; higher temperatures may require derating. Ensure adequate ventilation around the motor.
The base delivery includes the blower and motor only. Not included: inlet/outlet silencers, filters, flexible connectors, pressure relief valves, and motor protection devices. These must be ordered separately. Maintenance parts such as motor bearings (if replaceable) and gaskets are also not included.