Elmo Rietschle 2BH7410
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7410

Elmo Rietschle 2BH7410 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 2.6 kW, Noise level 73 dB.

Side-channel blower 2BH7410 (G-BH7 series) with integrated frequency converter, available as 2BH7410-0A3xx-1 or 2BH7410-0AKxx-1. It delivers up to 430 mbar gauge pressure and -410 mbar vacuum differential, with a 4.3 kW motor at 87 Hz delta (400 V, 8.7 A) or 3.5 kW at 50 Hz (380 V, 6.5 A). It serves as a compact, speed-controlled air source for pressure or vacuum duty in process systems.

Max. differential pressure
-230 mbar
Motor power
2.6 kW
Noise level
73 dB
Weight
33 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7410 Current 2.673-230335.2400
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -230 mbar
Motor power 2.6 kW
Noise level 73 dB(A)
Max. differential pressure vacuum mfr -410 mbar
Order No. mfr 2BH7410-0A311-1 (100 Hz)
Max. differential pressure (alt var) mfr 650 mbar
Max. differential pressure Vacuum (alt var) mfr -410 mbar
Dimensions, Weight & Mechanical Design
Weight 33 kg
Weight (alt var) mfr 41 kg
Electrical, Power & Drive Specifications
Current 5.2 A
Frequency 100 Hz
Power supply 3~ 400V -15% … 480V +10%, 50/60 Hz ±6%, IP55, UL 1450
Voltage 400 V
Rated motor voltage mfr 400 V (87 Hz, delta connection)
Rated motor current mfr 8.7 A (87 Hz, delta connection)
Rated motor power mfr 4.3 kW (87 Hz, delta connection)
Rated motor voltage mfr 380 V (50 Hz)
Rated motor current mfr 6.5 A (50 Hz)
Rated motor power mfr 3.5 kW (50 Hz)
Rated motor current mfr 5.2 A (100 Hz)
Current (alt var) mfr 8.7 A
Power (alt var) mfr 4.3 kW
Voltage (alt var) mfr 380 V
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 77 dB(A)
Sound pressure level mfr 73 dB(A) (100 Hz)
Sound pressure level (alt var) mfr 77 dB(A)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Motor winding is configured for delta at 87 Hz, not 50 Hz star

The 4.3 kW / 8.7 A rating applies only at 87 Hz in delta connection (400 V). Operating the same winding at 50 Hz yields 3.5 kW at 380 V / 6.5 A. Verify the winding configuration and converter output frequency before applying load, or the motor will be over- or under-fluxed.

Factory Specification Sheet
Process Limits
Do not exceed 430 mbar pressure or -410 mbar vacuum differential

These are the maximum differential pressures for the 2BH7410. Exceeding them in either direction risks overheating and mechanical damage to the side channel impeller. Size the process restriction and relief provisions so that neither limit is reached in normal or fault conditions.

Technical Data Sheet — G-BH7 2BH7410

Selection & Integration Q&A

When should I choose the 2BH7410 rather than the smaller 2BH7210 or 2BH7220 in the G-BH7 series?

Pick the 2BH7410 when the duty needs up to 430 mbar pressure or -410 mbar vacuum and roughly 3.5–4.3 kW. The 2BH721/2BH7210 and 2BH722/2BH7220 are smaller frames with lower capability; use them only if their pressure and flow cover the duty.

What drive and power supply arrangement does the 2BH7410 require?

It is supplied with an integrated frequency converter; the alternative is a matching external 2FC4xxx-1 converter (sizes A–K). The motor is wound for 400 V delta at 87 Hz (8.7 A, 4.3 kW) or 380 V at 50 Hz (6.5 A, 3.5 kW). Confirm the variant and winding before wiring.

What are the environmental and duty limits for installing this blower?

The motor is IP55 with class F insulation, so it tolerates dusty/damp industrial areas, but the 430 mbar / -410 mbar differential limits and 77 dB(A) noise must be respected. Ensure the process cannot drive the blower past those differentials in normal or fault operation.

What is included in base delivery and what must be ordered separately?

Base delivery is the blower with integrated converter (variant 2BH7410-0A3xx-1 or -0AKxx-1). External 2FC4xxx-1 converters, the G17 separately driven fan (36 kg version) and any cabling or mating flanges are separate items; confirm the scope on the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7410 side channel blower (EN)
Datasheet ·516,6 КБ ·2 pp.
View PDF