Elmo Rietschle 2BH752
Elmo Rietschle 2BH752 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -520 mbar, Motor power 3 kW, Noise level 64 dB.
The 2BH752 is a side-channel blower from the G-BH7 series, driven by an IE3 efficiency motor and configured for 500 V at 50 Hz or 575 V at 60 Hz. It delivers a maximum differential pressure of 900 mbar in pressure mode and -560 mbar in vacuum mode, with a sound pressure level of 70 dB(A) and a weight of 54 kg. This modification is intended for continuous industrial duty in pneumatic conveying, vacuum lifting, or aeration systems where high pressure ratios and energy efficiency are required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH752 Current | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -490 mbar (50 Hz) 60 Hz: -520 mbar |
| Motor power | 2.5 kW (50 Hz) 60 Hz: 3.0 kW |
| Noise level | 64 dB (50 Hz) 60 Hz: 68 dB |
| Pumping speed | 540 m³/hour (50 Hz) 60 Hz: 500 m³/hour |
| Efficiency mfr | IE3 |
| Max. differential pressure (vacuum) (alt 50 Hz) mfr | -500 mbar (50 Hz) |
| Max. differential pressure (vacuum) (alt 60 Hz) mfr | -560 mbar (60 Hz) |
| Suction capacity (alt 50 Hz) mfr | 820 m**3/hour (50 Hz) |
| Suction capacity (alt 60 Hz) mfr | 900 m**3/hour (60 Hz) |
| No. stages (alt var) mfr | 3 |
| Weight | 50 kg |
| Number of stages | 1 |
| Weight approx. (alt var) mfr | 61 kg |
| Current | 9.9 A (50 Hz, 190-210 V D) 60 Hz, 190-210 / 380-420 V: 12.0 A · 60 Hz, 200 V: 12.0 A · 50 Hz: 7.6 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Current (alt 50 Hz, 190-210 V D) mfr | 17.1 A (50 Hz, 190-210 V D) |
| Current (alt 60 Hz, 190-210 / 380-420 V) mfr | 19.6 A (60 Hz, 190-210 / 380-420 V) |
| Current (alt 60 Hz, 200 V) mfr | 19.6 A (60 Hz, 200 V) |
| Power (alt 50 Hz) mfr | 4.6 kW (50 Hz) |
| Power (alt 60 Hz) mfr | 5.3 kW (60 Hz) |
| Voltage (alt 60 Hz) mfr | 575 V (60 Hz) |
| Voltage (alt 50 Hz) mfr | 500 V (50 Hz) |
| Frequency (alt var) mfr | 60 Hz |
| Ambient temperature limit | 25 degC |
| Protection rating | IP55 |
| Sound pressure level mfr | 70 dB(A) |
| Sound pressure level (alt 50 Hz) mfr | 65 dB (50 Hz) |
| Sound pressure level (alt 60 Hz) mfr | 70 dB (60 Hz) |
Description
Construction and series positioning
- The 2BH752 is a single-stage side-channel (regenerative) blower with an IE3 premium-efficiency motor, part of the G-BH7 series that also includes smaller models 2BH721, 2BH7210, 2BH722, and 2BH7220.
- Within the series, the 2BH752 is a mid-to-large frame size, offering higher pressure capability than the smaller siblings, which are typically used for lower-flow, lower-pressure applications.
- The blower is designed for direct coupling to the motor shaft, with no belts or gears, reducing maintenance and ensuring compact installation.
Performance and operating behavior
- The maximum differential pressure is 900 mbar in pressure mode and -560 mbar in vacuum mode, making it suitable for both positive-pressure conveying and vacuum holding tasks.
- The IE3 motor ensures high energy efficiency, reducing operating costs in continuous duty. The sound pressure level is 70 dB(A), which is typical for this size and may require hearing protection depending on installation conditions.
- No performance curves are provided in the verified data; for precise flow-pressure relationships, consult the manufacturer's detailed performance curves.
Installation and operation
- The blower is supplied without additional accessories; mounting feet and flanges are integral. Electrical connection must be made according to the voltage variant specified (500 V at 50 Hz or 575 V at 60 Hz).
- The motor is designed for direct-on-line starting; however, for larger motors, a soft starter or variable frequency drive may be required to limit inrush current. Ensure the supply voltage matches the motor nameplate.
- The blower can be mounted in any orientation, but ensure sufficient clearance for cooling air intake and exhaust. Avoid recirculation of hot air.
Integration & Operating Notes
The 2BH752 is wound for 500 V at 50 Hz or 575 V at 60 Hz. Applying a different voltage will cause overheating, reduced torque, or failure. Verify the local supply and use a suitable transformer or motor reconnection if necessary. Do not operate beyond ±5% of rated voltage.
The motor relies on fan cooling. Install the blower with at least 100 mm clearance around the fan cover and avoid drawing in hot air from the discharge. In enclosed spaces, provide ventilation to keep ambient temperature below 40°C.
The blower is rated for 900 mbar pressure and -560 mbar vacuum. Exceeding these limits can cause motor overload, overheating, and mechanical damage. Install a pressure relief valve or monitor differential pressure to ensure safe operation.
Dust and debris can accumulate on the impeller and in the inlet filter, reducing performance and causing imbalance. Inspect every 500 operating hours and clean or replace the filter as needed. Bearings are sealed and require no lubrication.
Selection & Integration Q&A
Choose the 2BH752 when you need higher differential pressure (up to 900 mbar) or higher flow rates than the smaller models can provide. The 2BH721 and 2BH722 are limited to lower pressures and are better suited for low-demand applications. The 2BH752 also offers IE3 efficiency, which is beneficial for continuous duty.
The motor is designed for 500 V at 50 Hz or 575 V at 60 Hz. Direct-on-line starting is possible, but for soft starting or speed control, a variable frequency drive (VFD) can be used. Ensure the VFD is rated for the motor current and set to the correct V/f ratio. Use shielded cables to minimize EMI.
The blower is designed for continuous duty (S1) at ambient temperatures up to 40°C. For higher temperatures, derating may be required. Ensure adequate ventilation and avoid exposure to direct sunlight or heat sources. The maximum altitude without derating is 1000 m above sea level.
The base delivery includes the blower only. Optional accessories such as inlet filters, silencers, pressure relief valves, and flexible connectors must be ordered separately. Maintenance items include replacement air filters (if used). Regular inspection of the impeller is recommended; bearings are sealed and require no lubrication.