Elmo Rietschle 2BH752
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH752

Elmo Rietschle 2BH752 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -520 mbar, Motor power 3 kW, Noise level 64 dB.

The 2BH752 is a side-channel blower from the G-BH7 series, driven by an IE3 efficiency motor and configured for 500 V at 50 Hz or 575 V at 60 Hz. It delivers a maximum differential pressure of 900 mbar in pressure mode and -560 mbar in vacuum mode, with a sound pressure level of 70 dB(A) and a weight of 54 kg. This modification is intended for continuous industrial duty in pneumatic conveying, vacuum lifting, or aeration systems where high pressure ratios and energy efficiency are required.

Max. differential pressure
-520 mbar
Motor power
3 kW
Noise level
64 dB
Pumping speed
540 m³/h
Weight
50 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH752 Current 2.564-5205012190-210 / 380-420
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -490 mbar (50 Hz)
60 Hz: -520 mbar
Motor power 2.5 kW (50 Hz)
60 Hz: 3.0 kW
Noise level 64 dB (50 Hz)
60 Hz: 68 dB
Pumping speed 540 m³/hour (50 Hz)
60 Hz: 500 m³/hour
Efficiency mfr IE3
Max. differential pressure (vacuum) (alt 50 Hz) mfr -500 mbar (50 Hz)
Max. differential pressure (vacuum) (alt 60 Hz) mfr -560 mbar (60 Hz)
Suction capacity (alt 50 Hz) mfr 820 m**3/hour (50 Hz)
Suction capacity (alt 60 Hz) mfr 900 m**3/hour (60 Hz)
No. stages (alt var) mfr 3
Dimensions, Weight & Mechanical Design
Weight 50 kg
Number of stages 1
Weight approx. (alt var) mfr 61 kg
Electrical, Power & Drive Specifications
Current 9.9 A (50 Hz, 190-210 V D)
60 Hz, 190-210 / 380-420 V: 12.0 A · 60 Hz, 200 V: 12.0 A · 50 Hz: 7.6 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Current (alt 50 Hz, 190-210 V D) mfr 17.1 A (50 Hz, 190-210 V D)
Current (alt 60 Hz, 190-210 / 380-420 V) mfr 19.6 A (60 Hz, 190-210 / 380-420 V)
Current (alt 60 Hz, 200 V) mfr 19.6 A (60 Hz, 200 V)
Power (alt 50 Hz) mfr 4.6 kW (50 Hz)
Power (alt 60 Hz) mfr 5.3 kW (60 Hz)
Voltage (alt 60 Hz) mfr 575 V (60 Hz)
Voltage (alt 50 Hz) mfr 500 V (50 Hz)
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Ambient temperature limit 25 degC
Protection rating IP55
Sound pressure level mfr 70 dB(A)
Sound pressure level (alt 50 Hz) mfr 65 dB (50 Hz)
Sound pressure level (alt 60 Hz) mfr 70 dB (60 Hz)

Description

Construction and series positioning

Performance and operating behavior

Installation and operation

Integration & Operating Notes

Electrical
Supply voltage must match motor nameplate exactly

The 2BH752 is wound for 500 V at 50 Hz or 575 V at 60 Hz. Applying a different voltage will cause overheating, reduced torque, or failure. Verify the local supply and use a suitable transformer or motor reconnection if necessary. Do not operate beyond ±5% of rated voltage.

Technical Data Sheet — 2BH752 IE3 vacuum pump (EN), voltage variants section
Mounting
Ensure unobstructed cooling air flow

The motor relies on fan cooling. Install the blower with at least 100 mm clearance around the fan cover and avoid drawing in hot air from the discharge. In enclosed spaces, provide ventilation to keep ambient temperature below 40°C.

Technical Data Sheet — 2BH752 IE3 vacuum pump (EN), installation notes
Process Limits
Do not exceed maximum differential pressure

The blower is rated for 900 mbar pressure and -560 mbar vacuum. Exceeding these limits can cause motor overload, overheating, and mechanical damage. Install a pressure relief valve or monitor differential pressure to ensure safe operation.

Technical Data Sheet — 2BH752 IE3 vacuum pump (EN), performance data
Maintenance
Regularly inspect and clean the impeller and filter

Dust and debris can accumulate on the impeller and in the inlet filter, reducing performance and causing imbalance. Inspect every 500 operating hours and clean or replace the filter as needed. Bearings are sealed and require no lubrication.

Technical Data Sheet — 2BH752 IE3 vacuum pump (EN), maintenance section

Selection & Integration Q&A

When should I choose the 2BH752 over the smaller 2BH721 or 2BH722 models?

Choose the 2BH752 when you need higher differential pressure (up to 900 mbar) or higher flow rates than the smaller models can provide. The 2BH721 and 2BH722 are limited to lower pressures and are better suited for low-demand applications. The 2BH752 also offers IE3 efficiency, which is beneficial for continuous duty.

What are the requirements for the electrical supply and starting method?

The motor is designed for 500 V at 50 Hz or 575 V at 60 Hz. Direct-on-line starting is possible, but for soft starting or speed control, a variable frequency drive (VFD) can be used. Ensure the VFD is rated for the motor current and set to the correct V/f ratio. Use shielded cables to minimize EMI.

What are the ambient temperature and duty cycle limits for this blower?

The blower is designed for continuous duty (S1) at ambient temperatures up to 40°C. For higher temperatures, derating may be required. Ensure adequate ventilation and avoid exposure to direct sunlight or heat sources. The maximum altitude without derating is 1000 m above sea level.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower only. Optional accessories such as inlet filters, silencers, pressure relief valves, and flexible connectors must be ordered separately. Maintenance items include replacement air filters (if used). Regular inspection of the impeller is recommended; bearings are sealed and require no lubrication.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH752 IE3 vacuum pump (EN)
Datasheet ·932,5 КБ ·3 pp.
View PDF