Elmo Rietschle 2BH742
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH742

Elmo Rietschle 2BH742 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 410 mbar, Motor power 2 kW, Noise level 64 dB.

The 2BH742 is a side-channel (regenerative ring) blower from Elmo Rietschle's G-BH7 series, built with an IE3 efficiency-class motor and IP55 protection. It delivers up to 460 mbar gauge pressure or -500 mbar vacuum, with a 2.0 kW rating at 50 Hz and dual voltage 190-210/380-420 V. This modification is positioned as a mid-range unit in the series, suitable for continuous duty in pneumatic conveying, vacuum holding, or aeration processes where moderate pressure and vacuum are required.

Max. differential pressure
410 mbar
Motor power
2 kW
Noise level
64 dB
Ultimate pressure
-500 mbar
Weight
38 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH742 Current 1.864460383.9–7.8190-210 / 380-420
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 460 mbar (50 Hz, IE3)
60 Hz, IE3: 410 mbar · 60 Hz, NP: 410 mbar
Motor power 1.8 kW (50 Hz)
60 Hz: 2.0 kW
Noise level 64 dB (50 Hz)
60 Hz: 67 dB
Ultimate pressure -500 mbar
Max. differential pressure (vacuum) mfr -500 mbar (50 Hz)
Max. differential pressure (vacuum) mfr -500 mbar (60 Hz)
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Order No. mfr 2BH7420-0AK21-1
Max. differential pressure vacuum mfr -500 mbar (50 Hz)
Max. differential pressure vacuum mfr -500 mbar (60 Hz)
Approx. Order No. mfr 2BH7420-0AK21-1
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Dimensions, Weight & Mechanical Design
Weight 38 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 6.9 A (50 Hz)
60 Hz: 7.8 / 3.9 A
Power supply 3~ 50/60 Hz
Voltage 190-210 △ V (50 Hz)
60 Hz: 190-210 / 380-420 V · 60 Hz, NP: 200 V
Frequency mfr 50 Hz (50 Hz)
Frequency mfr 60 Hz (60 Hz)
Efficiency class mfr IE3
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (NEMA Premium) (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 64 dB(A) (50 Hz)
Sound pressure level mfr 67 dB(A) (60 Hz)

Description

Construction and series positioning

The 2BH742 (order code 2BH7420-0AK21-1) is a side-channel blower featuring a dynamically balanced impeller running in a ring-shaped channel, with an IE3-class motor directly coupled to the impeller shaft. The motor is rated IP55 and insulation class F, and the unit carries UL 1450 and CAN/CSA C22.2 No. 68-09 approvals (certificate E225239). Weighing 38 kg, it is a compact yet robust machine. Within the G-BH7 series, the 2BH742 sits between the smaller 2BH721/2BH722 variants and larger sizes, offering a balanced pressure/vacuum capability for medium-duty applications. The dual voltage range (190-210 V or 380-420 V at both 50 and 60 Hz) allows operation on common industrial supplies without a transformer.

Performance characteristics

At 50 Hz, the blower produces a maximum differential pressure of 460 mbar in pressure mode and -500 mbar in vacuum mode, with a motor power of 1.8 kW and a current of 6.9 A. At 60 Hz, the motor power is 2.0 kW, the current is 7.8 / 3.9 A, and the maximum differential pressure is 410 mbar in pressure mode; the vacuum limit remains -500 mbar. Sound pressure level is 64 dB(A) at 50 Hz and 67 dB(A) at 60 Hz. The unit is intended for continuous operation, but the absence of digitized curve points means that the exact flow-pressure relationship must be obtained from the manufacturer's performance curves for precise system design.

Installation and operation

The blower is typically mounted on a rigid base using the provided mounting feet, with flexible connections to inlet and outlet to avoid transmitting vibration. The IP55 motor allows installation in dusty or damp environments, but the ambient temperature and altitude must be within the motor's rated limits. Electrical connection requires a suitable motor protection circuit breaker set to the rated current (6.9 A at 50 Hz, 7.8 / 3.9 A at 60 Hz) and a contactor for start/stop control. The motor is not equipped with a built-in thermal sensor, so external overload protection is mandatory. The blower can be operated in either pressure or vacuum mode by swapping the inlet and outlet connections, but the direction of rotation must be correct (indicated by an arrow on the casing). No variable frequency drive is required, but if used, the motor insulation is class F, which permits VFD operation with appropriate filtering.

Integration & Operating Notes

Electrical
Motor protection must be set to 6.9 A at 50 Hz or 7.8 / 3.9 A at 60 Hz

The motor has no integral thermal overload. A separate motor protection switch or overload relay must be installed and set to the rated current for the actual supply frequency. Exceeding this current risks winding damage and voids the UL approval.

Technical Data Sheet — 2BH742 IE3 vacuum pump (EN), Electrical Data
Mounting
Use flexible connectors to isolate vibration from piping

The blower generates vibration during operation. Rigid piping can transmit this vibration to the system, causing fatigue and noise. Install flexible hoses or expansion joints at both inlet and outlet, and mount the unit on a flat, vibration-damped surface.

Technical Data Sheet — 2BH742 IE3 vacuum pump (EN), Installation
Control & I/O
Ensure correct rotation direction before coupling to process

The blower is direction-sensitive; reverse rotation can cause inadequate performance and potential overheating. Check the rotation arrow on the casing and verify motor phasing before connecting to the process. For three-phase units, a phase sequence relay is recommended.

Technical Data Sheet — 2BH742 IE3 vacuum pump (EN), Commissioning
Process Limits
Do not exceed 460 mbar pressure (50 Hz) or 410 mbar pressure (60 Hz); vacuum limit is -500 mbar

Operating beyond these differential pressure limits can cause motor overload, excessive temperature rise, and mechanical damage. The pressure limit is 460 mbar at 50 Hz and 410 mbar at 60 Hz; the vacuum limit is -500 mbar at both frequencies. Use pressure relief valves or vacuum breakers to protect the blower in blocked-flow conditions.

Technical Data Sheet — 2BH742 IE3 vacuum pump (EN), Performance Limits
Maintenance
Inspect and clean the impeller and channel periodically

Dust and debris can accumulate in the side channel, reducing performance and causing imbalance. The maintenance interval depends on the process air cleanliness; in dusty environments, monthly inspection is advised. Bearings are sealed for life and require no lubrication.

Technical Data Sheet — 2BH742 IE3 vacuum pump (EN), Maintenance

Selection & Integration Q&A

When should I choose the 2BH742 instead of a smaller sibling like the 2BH721 or 2BH722?

Choose the 2BH742 when your process requires up to 460 mbar pressure (50 Hz) or 410 mbar pressure (60 Hz), or up to -500 mbar vacuum, with a motor power of 1.8 kW at 50 Hz or 2.0 kW at 60 Hz. The 2BH721 and 2BH722 offer lower pressure/vacuum capabilities and are suited for smaller flows. The 2BH742 provides a higher margin for medium-duty applications without moving to a larger frame size.

What are the requirements for the motor protection and electrical supply for this blower?

The motor is dual-voltage (190-210 V or 380-420 V) at 50 or 60 Hz. You must provide a motor protection circuit breaker set to 6.9 A at 50 Hz or 7.8 / 3.9 A at 60 Hz. The supply must be capable of delivering the starting current, and for three-phase versions, a phase sequence relay is recommended to prevent reverse rotation.

What maintenance items and accessories are not included with the base blower?

The base delivery includes the blower only. You must separately order flexible connectors, a motor protection switch, and a contactor. No spare parts kit is included; recommended spares are the inlet/outlet gaskets and a replacement impeller if wear is expected. Bearings are sealed and not user-serviceable.