Elmo Rietschle 2BH731
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH731

Elmo Rietschle 2BH731 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -340 mbar, Motor power 1.6 kW, Noise level 58 dB.

The 2BH731 is a single-stage side-channel blower from the G-BH7 series, driven by a 1.6 kW IE3 motor for 50/60 Hz operation. It delivers a maximum vacuum of -340 mbar and is distinguished from smaller siblings (2BH721, 2BH722) by its higher displacement and motor rating. It serves as a compact vacuum source in pneumatic conveying, suction holding, and extraction duties where oil-free, pulsation-free operation is required.

Max. differential pressure
-340 mbar
Motor power
1.6 kW
Noise level
58 dB
Ultimate pressure
340 mbar
Weight
22 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH731 Current 1.163-340242.8–5.5190-210 / 380-420
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -280 mbar (50 Hz)
60 Hz: -340 mbar
Motor power 1.0 kW (50 Hz)
60 Hz: 1.1 kW · 50 Hz (size 2): 1.3 kW · 60 Hz (size 2): 1.6 kW
Noise level 58 dB (50 Hz)
60 Hz: 62 dB · 50 Hz (size 2): 59 dB · 60 Hz (size 2): 63 dB
Ultimate pressure 350 mbar (50 Hz)
60 Hz: 340 mbar · 60 Hz (size 2): 460 mbar
Efficiency mfr IE3 (50 Hz)
Efficiency mfr NP (60 Hz)
Vacuum mfr -280 mbar (50 Hz)
Approx. Order No. mfr 2BH7310-0AK31-1 (50 Hz)
Vacuum mfr -340 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 22 kg (size 1)
size 2: 24 kg
Number of stages 1 (size 1)
size 2: 2
Electrical, Power & Drive Specifications
Current 4.2 A (50 Hz)
60 Hz: 4.8 A · 50 Hz (size 2): 5.6 A · 60 Hz (size 2): 6.3 A · 50 Hz (220-240/380-420 V): 3.7 / 2.1 A · 60 Hz (220-240/440-480 V): 4.2 / 2.1 A · 50 Hz (size 2, 220-240/380-420 V): 4.9 / 2.9 A · 60 Hz (size 2, 220-240/440-480 V): 5.5 / 2.8 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Voltage range mfr 220-240 V∆ / 380-420 V Y V (50 Hz)
Voltage range mfr 440-480 V Y V (60 Hz)
Voltage (alt 50 Hz) mfr 220-240 / 380-420 V (50 Hz)
Voltage (alt 60 Hz) mfr 220-240 / 440-480 V (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 58 dB(A) (50 Hz)
Sound pressure level mfr 62 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behaviour

Installation and operation

Integration & Operating Notes

Electrical
Supply voltage must match motor winding configuration

The motor is wound for dual voltage (220–240 VΔ / 380–420 VY at 50 Hz; 440–480 VY at 60 Hz). Connecting to an incorrect voltage or winding configuration will cause overheating, reduced torque, or immediate failure. Verify the terminal link position against the nameplate before energising.

Technical Data Sheet — 2BH731 IE3 vacuum pump (EN)
Mounting
Install on a rigid, level base to limit vibration

The 24 kg blower generates rotational forces; mounting on a flexible or uneven surface can amplify vibration, accelerate bearing wear, and increase noise. Use appropriate anti-vibration mounts if the structure is not rigid, and ensure the mounting bolts are tightened to the recommended torque.

Technical Data Sheet — 2BH731 IE3 vacuum pump (EN)
Process Limits
Do not exceed -340 mbar differential pressure

Operating above the maximum vacuum of -340 mbar will overload the motor and may cause thermal protection tripping or mechanical damage. Install a vacuum relief valve or pressure switch to limit the differential pressure in the system, especially during startup or blockage conditions.

Technical Data Sheet — 2BH731 IE3 vacuum pump (EN)
Maintenance
Regularly inspect and clean the impeller and filter

Dust and debris accumulation on the impeller or in the inlet filter reduces performance and can cause imbalance. Inspect and clean these components at intervals determined by the process dust load; in heavy-duty applications, weekly checks may be necessary. Replace the filter element when pressure drop becomes excessive.

Technical Data Sheet — 2BH731 IE3 vacuum pump (EN)

Selection & Integration Q&A

When should I choose the 2BH731 instead of a smaller sibling like the 2BH721 or 2BH722?

Choose the 2BH731 when your process requires a vacuum level down to -340 mbar and a motor power of 1.6 kW. The 2BH721 and 2BH722 offer lower displacement and are suited for lower flow or vacuum demands. The 2BH731 provides higher capacity in the same footprint, making it preferable for demanding suction or conveying tasks.

What are the environmental and duty-cycle limitations for installing the 2BH731?

The 2BH731 is rated IP55, so it can be installed in dusty or damp environments but not submerged. Ambient temperature limits are not specified in the digest; refer to the manual. It is designed for continuous duty (S1) but should not be operated above the maximum differential pressure of -340 mbar. Ensure adequate ventilation around the motor to prevent overheating.

What maintenance items and accessories are required for the 2BH731, and are they included?

The base delivery typically includes the blower only. Accessories such as inlet filters, vacuum relief valves, and mounting feet are usually ordered separately. Maintenance includes periodic cleaning of the impeller and filter, checking terminal tightness, and bearing lubrication (if applicable). Refer to the manual for specific intervals; no consumables are included in the standard scope.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH731 IE3 vacuum pump (EN)
Datasheet ·292,2 КБ ·2 pp.
View PDF