Elmo Rietschle 2BH722
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH722

Elmo Rietschle 2BH722 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 490 mbar, Motor power 1 kW, Noise level 63 dB.

The 2BH722 is a side-channel (regenerative ring) blower from Elmo Rietschle's G-BH7 series, driven by a 2.0 kW IE3-class motor in IP55 protection. It delivers up to 480 mbar differential pressure in either vacuum or pressure mode at both 50 and 60 Hz, distinguishing it from lower-capacity siblings such as the 2BH721. Its primary role is to provide oil-free, pulsation-free air for vacuum holding, pneumatic conveying, or low-pressure aeration in industrial systems.

Max. differential pressure
490 mbar
Motor power
1 kW
Noise level
63 dB
Ultimate pressure
-370 mbar
Weight
28 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH722 Current 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 490 mbar (50 Hz)
60 Hz: 480 mbar
Motor power 1.0 kW (50 Hz)
60 Hz: 1.1 kW
Noise level 58 dB(A) (50 Hz)
60 Hz: 63 dB(A)
Ultimate pressure -370 mbar (50 Hz)
60 Hz: -480 mbar
Max. differential pressure (vacuum) mfr -480 mbar (50 Hz)
Max. differential pressure (vacuum) mfr -480 mbar (60 Hz)
Order No. mfr 2BH7220-0AK31-1
Max. differential pressure vacuum mfr -370 mbar (50 Hz)
Max. differential pressure vacuum mfr -480 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 28 kg
Electrical, Power & Drive Specifications
Current 4.2 A (50 Hz)
60 Hz: 4.8 UU / 2.4 U A
Frequency 50/60 Hz
Voltage 190-210 D V (50 Hz)
60 Hz: 190-210 UU / 380-420 U V
Efficiency class mfr IE3 (50 Hz)
Rated voltage mfr 200 UU V (60 Hz)
Rated current mfr 4.8 UU A (60 Hz)
Rated power mfr 1.1 kW (60 Hz)
Efficiency class mfr NP (60 Hz)
Voltage (alt 60 Hz) mfr 200 UU V (60 Hz)
Current (alt 60 Hz) mfr 4.8 UU A (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 58 dB(A) (50 Hz)
Sound pressure level mfr 63 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and control

Integration & Operating Notes

Electrical
Motor protection must be set to 3.5 A (Δ) or 1.7 A (Y) at 50 Hz

The 1.1 kW (60 Hz) / 1.0 kW (50 Hz) IE3 motor draws 3.5 A per phase in delta and 1.7 A in star at 50 Hz, and 1.8 A at 60 Hz. A thermal overload relay or VFD must be configured to these currents to prevent winding damage from sustained overload, especially during cold starts or if the blower is operated near its maximum differential pressure.

Technical Data Sheet — 2BH722 IE3 vacuum pump (EN), Electrical Data
Process Limits
Differential pressure must not exceed 480 mbar (60 Hz) or 490 mbar (50 Hz) in either mode

The blower is rated for a maximum differential pressure of 480 mbar at 60 Hz and 490 mbar at 50 Hz in both vacuum and pressure operation. Exceeding this limit will cause excessive temperature rise and may lead to impeller rubbing or motor overload. A pressure relief valve or bypass should be installed if the process can generate higher differentials.

Technical Data Sheet — 2BH722 IE3 vacuum pump (EN), Performance Data

Selection & Integration Q&A

When should I choose the 2BH722 instead of a sibling model like the 2BH721 or 2BH731?

Choose the 2BH722 when you need up to 480 mbar differential pressure at 60 Hz (490 mbar at 50 Hz) with a 1.1 kW (60 Hz) / 1.0 kW (50 Hz) IE3 motor. The 2BH721 offers lower pressure at similar power, while the 2BH731 provides higher flow but larger size. The 2BH722 is the mid-range compromise for vacuum or pressure duty.

What are the requirements for the motor starter or VFD when integrating this blower?

The motor is dual-voltage: 380–420 V Δ / 690 V Y at 50 Hz, or 460 V Δ at 60 Hz. Use a motor protection switch set to 3.5 A (Δ) or 1.7 A (Y) at 50 Hz, or 1.8 A at 60 Hz. For VFD operation, ensure the drive is rated for the motor current and set the V/f curve to avoid overfluxing at low speeds.

Can the 2BH722 be installed outdoors, and what are the duty-cycle limits?

Yes, the IP55 rating allows outdoor installation, but the blower should be shielded from direct rain to prevent water ingress into the inlet/outlet. It is designed for continuous duty (S1) at ambient temperatures up to 40°C; higher temperatures may require derating. Ensure adequate ventilation around the motor.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower and motor only. Not included: inlet/outlet silencers, filters, flexible connectors, pressure relief valves, and motor protection devices. These must be ordered separately. Maintenance parts such as motor bearings (if replaceable) and gaskets are also not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH722 IE3 vacuum pump (EN)
Datasheet ·1,1 МБ ·2 pp.
View PDF