Elmo Rietschle 2BH7620
Elmo Rietschle 2BH7620 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -530 mbar, Motor power 8.8 kW, Noise level 79 dB.
The 2BH7620 is a side-channel blower from the G-BH7 e series with an integrated frequency converter, rated 10.2 kW at 50 Hz and 12.1 kW at 60 Hz. It delivers up to ±570 mbar differential pressure at 50 Hz and ±530 mbar at 60 Hz, distinguishing it from smaller siblings in the series. It is used for vacuum or pressure duty in industrial processes requiring compact, variable-speed blower packages.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7620 Current | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -530 mbar |
| Motor power | 8.8 kW |
| Noise level | 79 dB(A) |
| Max. differential pressure vacuum mfr | -570 mbar (50 Hz) |
| VFD type mfr | 2BH7620-0A341-2 |
| Motor connection mfr | delta |
| Performance basis atmospheric pressure mfr | 1013 mbar |
| Performance curve tolerance mfr | ± 10 % |
| Max. differential pressure (alt var) mfr | 390 mbar |
| Weight | 77 kg |
| Weight approx. mfr | 75 kg |
| Current | 16.2 A |
| Frequency | 100 Hz |
| Power supply | 3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 |
| Voltage | 400 V |
| Rated motor voltage mfr | 380 V (50 Hz) |
| Rated motor current mfr | 20.3 A (50 Hz) |
| Rated motor power mfr | 10.2 kW (50 Hz) |
| Rated motor voltage mfr | 400 V (60 Hz) |
| Rated motor current mfr | 22.0 A (60 Hz) |
| Rated motor power mfr | 12.1 kW (60 Hz) |
| Frequency converter rated mains voltage mfr | 400V (-15%) ... 480V (+10%) V |
| Frequency converter mains frequency mfr | 50/60 Hz (±6%) |
| Rated motor voltage mfr | 400 V |
| Rated motor current mfr | 16.2 A |
| Operating voltage/frequency set point mfr | 345 V / 87 Hz |
| Frequency converter min. mains voltage mfr | 380 V |
| Frequency converter pulse frequency minimum mfr | 4 kHz |
| Integrated VFD mains voltage mfr | 400V -15% ... 480V +10% V |
| Integrated VFD frequency mfr | 50/60 Hz (±6%) |
| Protection rating | IP55 |
| Operating temperature | 25 °C |
| Sound pressure level mfr | 75 dB(A) (50 Hz) |
| Sound pressure level mfr | 79 dB(A) (60 Hz) |
| Sound pressure level with G17 mfr | 75/76 dB(A) (50/60 Hz) |
| Sound pressure level mfr | 77 dB(A) |
| Sound pressure level with G17 mfr | 75 dB(A) |
Description
Construction and series positioning
- The 2BH7620 is a side-channel (regenerative) blower with an integrated frequency converter, part of the G-BH7 e series. Unlike the smaller 2BH721/2BH722 variants, this model provides higher power (10.2 kW at 50 Hz) and differential pressure up to ±570 mbar.
- The integrated converter allows speed variation from a 50/60 Hz mains supply without external VFD hardware, simplifying installation.
- Protection class IP55 and insulation class F make it suitable for dusty or humid industrial environments.
Performance and load behavior
- At 50 Hz, maximum differential pressure is 570 mbar in both vacuum and pressure modes; at 60 Hz, it is 530 mbar. The motor is rated 10.2 kW at 50 Hz and 12.1 kW at 60 Hz.
- Sound pressure level is 75 dB(A) at 50 Hz and 79 dB(A) at 60 Hz; with the G17 silencer option, levels are 75/76 dB(A) at 50/60 Hz.
- No digitized curve points are available; for precise flow-pressure characteristics, consult the manufacturer's performance curves.
Installation and operation
- The integrated frequency converter accepts 400 V (-15%) to 480 V (+10%) mains at 50/60 Hz (±6%). Motor voltage is 380 V at 50 Hz and 400 V at 60 Hz.
- The blower weighs approximately 75 kg and must be mounted on a rigid, level surface. Ensure adequate ventilation around the motor and converter.
- Electrical connection must be made by qualified personnel according to local codes and the instruction manual.
Integration & Operating Notes
The integrated frequency converter is rated for 400 V (-15%) to 480 V (+10%) at 50/60 Hz (±6%). Exceeding these limits risks converter damage and invalidates warranty. Verify supply voltage and frequency stability before commissioning.
Operating above 570 mbar differential pressure (vacuum or pressure) at 50 Hz may cause overheating and motor overload. At 60 Hz, the limit is 530 mbar. Use pressure relief or bypass if process can exceed these values.
The blower weighs approximately 75 kg. Install on a flat, vibration-resistant base. Ensure unobstructed air intake and exhaust, and allow space for maintenance access and cooling air flow around the motor and converter.
Dust accumulation on the motor and converter cooling fins can cause overheating. Check and clean periodically according to the instruction manual. Replace worn seals and bearings as recommended by the manufacturer.
Selection & Integration Q&A
Choose the 2BH7620 when you need higher differential pressure (up to ±570 mbar at 50 Hz) and motor power (10.2 kW). The 2BH7210 and 2BH7220 offer lower pressure and power, suitable for smaller flows or lower pressure ratios. Select based on required flow and pressure at operating speed.
The converter requires a 3-phase supply of 400 V (-15%) to 480 V (+10%) at 50/60 Hz (±6%). Use fuses or circuit breakers rated for the converter input current (consult manual). Ensure proper earthing and shielded motor cables to meet EMC requirements.
The data sheet does not specify ambient temperature limits; refer to the instruction manual. Typically, side channel blowers are rated for continuous duty (S1) at ambient up to 40°C. Ensure adequate cooling and avoid exceeding maximum differential pressure to prevent overheating.
The base delivery includes the blower with integrated converter. Silencers (e.g., G17), filters, and connection flanges are optional accessories. Spare parts such as bearings, seals, and filter elements must be ordered separately. Regular maintenance includes cleaning filters and checking electrical connections.