Elmo Rietschle 2BH731
Elmo Rietschle 2BH731 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -340 mbar, Motor power 1.6 kW, Noise level 58 dB.
The 2BH731 is a single-stage side-channel blower from the G-BH7 series, driven by a 1.6 kW IE3 motor for 50/60 Hz operation. It delivers a maximum vacuum of -340 mbar and is distinguished from smaller siblings (2BH721, 2BH722) by its higher displacement and motor rating. It serves as a compact vacuum source in pneumatic conveying, suction holding, and extraction duties where oil-free, pulsation-free operation is required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH731 Current | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -280 mbar (50 Hz) 60 Hz: -340 mbar |
| Motor power | 1.0 kW (50 Hz) 60 Hz: 1.1 kW · 50 Hz (size 2): 1.3 kW · 60 Hz (size 2): 1.6 kW |
| Noise level | 58 dB (50 Hz) 60 Hz: 62 dB · 50 Hz (size 2): 59 dB · 60 Hz (size 2): 63 dB |
| Ultimate pressure | 350 mbar (50 Hz) 60 Hz: 340 mbar · 60 Hz (size 2): 460 mbar |
| Efficiency mfr | IE3 (50 Hz) |
| Efficiency mfr | NP (60 Hz) |
| Vacuum mfr | -280 mbar (50 Hz) |
| Approx. Order No. mfr | 2BH7310-0AK31-1 (50 Hz) |
| Vacuum mfr | -340 mbar (60 Hz) |
| Weight | 22 kg (size 1) size 2: 24 kg |
| Number of stages | 1 (size 1) size 2: 2 |
| Current | 4.2 A (50 Hz) 60 Hz: 4.8 A · 50 Hz (size 2): 5.6 A · 60 Hz (size 2): 6.3 A · 50 Hz (220-240/380-420 V): 3.7 / 2.1 A · 60 Hz (220-240/440-480 V): 4.2 / 2.1 A · 50 Hz (size 2, 220-240/380-420 V): 4.9 / 2.9 A · 60 Hz (size 2, 220-240/440-480 V): 5.5 / 2.8 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Voltage range mfr | 220-240 V∆ / 380-420 V Y V (50 Hz) |
| Voltage range mfr | 440-480 V Y V (60 Hz) |
| Voltage (alt 50 Hz) mfr | 220-240 / 380-420 V (50 Hz) |
| Voltage (alt 60 Hz) mfr | 220-240 / 440-480 V (60 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 58 dB(A) (50 Hz) |
| Sound pressure level mfr | 62 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with an IE3 efficiency-class motor, IP55 protection, insulation class F.
- Weighs 24 kg; voltage ranges 220–240 VΔ / 380–420 VY at 50 Hz and 440–480 VY at 60 Hz.
- Within the G-BH7 series, the 2BH731 sits above the 2BH721 and 2BH722 variants, offering higher power (1.6 kW) and deeper vacuum (-340 mbar) than those smaller models.
Performance behaviour
- Maximum differential pressure is -280 mbar at 50 Hz and -340 mbar at 60 Hz.
- Current draw is 4.9/2.9 A at 50 Hz (size 2, 220–240/380–420 V) and 5.5/2.8 A at 60 Hz (size 2, 220–240/440–480 V), reflecting the dual-voltage motor windings.
- Sound pressure level is 59 dB(A) at 50 Hz and 63 dB(A) at 60 Hz (size 2).
Installation and operation
- The motor is rated for continuous duty and requires a 3-phase supply matching the nameplate voltage; IE3 efficiency reduces operating energy cost.
- IP55 protection allows installation in dusty or damp industrial environments, but the blower should be mounted on a rigid, level surface to avoid vibration.
- Refer to the full manual for terminal box wiring and any optional accessories.
Integration & Operating Notes
The motor is wound for dual voltage (220–240 VΔ / 380–420 VY at 50 Hz; 440–480 VY at 60 Hz). Connecting to an incorrect voltage or winding configuration will cause overheating, reduced torque, or immediate failure. Verify the terminal link position against the nameplate before energising.
The 24 kg blower generates rotational forces; mounting on a flexible or uneven surface can amplify vibration, accelerate bearing wear, and increase noise. Use appropriate anti-vibration mounts if the structure is not rigid, and ensure the mounting bolts are tightened to the recommended torque.
Operating above the maximum vacuum of -340 mbar will overload the motor and may cause thermal protection tripping or mechanical damage. Install a vacuum relief valve or pressure switch to limit the differential pressure in the system, especially during startup or blockage conditions.
Dust and debris accumulation on the impeller or in the inlet filter reduces performance and can cause imbalance. Inspect and clean these components at intervals determined by the process dust load; in heavy-duty applications, weekly checks may be necessary. Replace the filter element when pressure drop becomes excessive.
Selection & Integration Q&A
Choose the 2BH731 when your process requires a vacuum level down to -340 mbar and a motor power of 1.6 kW. The 2BH721 and 2BH722 offer lower displacement and are suited for lower flow or vacuum demands. The 2BH731 provides higher capacity in the same footprint, making it preferable for demanding suction or conveying tasks.
The 2BH731 is rated IP55, so it can be installed in dusty or damp environments but not submerged. Ambient temperature limits are not specified in the digest; refer to the manual. It is designed for continuous duty (S1) but should not be operated above the maximum differential pressure of -340 mbar. Ensure adequate ventilation around the motor to prevent overheating.
The base delivery typically includes the blower only. Accessories such as inlet filters, vacuum relief valves, and mounting feet are usually ordered separately. Maintenance includes periodic cleaning of the impeller and filter, checking terminal tightness, and bearing lubrication (if applicable). Refer to the manual for specific intervals; no consumables are included in the standard scope.