Elmo Rietschle 2BH7310
Elmo Rietschle 2BH7310 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 250 mbar, Motor power 0.63 kW, Noise level 58 dB.
The 2BH7310 is a single-stage side-channel (regenerative) blower in Elmo Rietschle's G-BH7 series, configured with a 0.94 kW (50 Hz) / 1.06 kW (60 Hz) motor and a 25 kg cast construction. It delivers up to 360 mbar differential pressure in pressure duty and -340 mbar in vacuum duty, distinguishing it from smaller siblings (2BH7210, 2BH7220) by its higher power and pressure capability. It serves as a compact, oil-free air mover for pressure or vacuum holding in industrial processes.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7310 Current | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | 250 mbar (50 Hz) 60 Hz: 250 mbar |
| Motor power | 0.55 kW (50 Hz) 60 Hz: 0.63 kW |
| Noise level | 58 dB (50 Hz) 60 Hz: 62 dB |
| Ultimate pressure | -250 mbar (50 Hz) 60 Hz: -260 mbar |
| Max. differential pressure vacuum mfr | -340 mbar |
| Order No. mfr | 2BH7310-0AV75-7 |
| Rated pressure vacuum mfr | -250 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | 350 mbar (50 Hz) |
| Order No. mfr | 2BH7310-0AV75-7 (50 Hz) |
| Rated pressure vacuum mfr | -280 mbar (60 Hz) |
| Max. differential pressure vacuum mfr | 390 mbar (60 Hz) |
| Atmospheric pressure basis mfr | 1013 mbar |
| Performance curve tolerance mfr | ±10 % |
| Weight mfr | 25 kg |
| Weight approx. mfr | 25 kg (50 Hz) |
| Weight approx. mfr | 25 kg (60 Hz) |
| Current | 2.8 / 1.6 Y A (50 Hz) 60 Hz: 3.0 / 1.7 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 200-240 / 345-415 Y V (50 Hz) 60 Hz: 220-275 / 380-480 Y V |
| Rated voltage mfr | 220-275 Δ / 380-480 Y V (60 Hz) |
| Rated current mfr | 4.0 Δ / 2.3 Y A (60 Hz) |
| Rated voltage mfr | 115 / 230 V (50/60 Hz) |
| Rated current mfr | 18.0 / 9.0 A (50/60 Hz) |
| Frequency tolerance mfr | ±2 % |
| Protection rating | IP55 |
| Operating temperature | F |
| Sound pressure level mfr | 58 dB(A) (50 Hz) |
| Sound pressure level mfr | 62 dB(A) (60 Hz) |
| Sound pressure level mfr | 62 dB(A) |
Description
Construction and series positioning
- Single-stage side-channel blower with a directly coupled motor; no belts or external gearing.
- The 2BH7310 sits above the 2BH7210 and 2BH7220 in the G-BH7 family, offering higher motor power (0.94 kW at 50 Hz) and correspondingly higher differential pressure limits.
- Ordering code 2BH7310-0AV75-7 indicates a specific motor/voltage configuration; other suffixes denote different voltage or frequency variants.
- Cast housing and 25 kg mass provide stable mounting and moderate thermal inertia.
Behavior under load and media
- Maximum differential pressure is 360 mbar in pressure mode and -340 mbar in vacuum mode; these are the upper limits for continuous operation.
- No digitized curve points are available in the supplied facts, so the exact pressure-flow characteristic must be taken from the manufacturer's performance curve for the specific voltage/frequency.
- The machine is oil-free and contact-free between impeller and housing; it is suitable for air and neutral gases, but not for aggressive or explosive media unless explicitly certified.
- Sound pressure level is 60 dB(A) at 50 Hz and 62 dB(A) at 60 Hz, measured at the standard reference point.
Electrical and control specifics
- Dual voltage/frequency options: 200–240 V at 50 Hz; 220–275 V Δ / 380–480 V Y at 60 Hz; also 115/230 V at 50/60 Hz with 18.0/9.0 A.
- Motor is rated for 0.94 kW at 50 Hz and 1.06 kW at 60 Hz; current draw depends on connection (Δ or Y) and supply frequency.
- The data sheet mentions VFD (87 Hz) operation as an option; this requires a motor suitable for inverter duty and may require derating or additional cooling.
- No integrated control or I/O is provided; the blower is a pure electromechanical actuator that must be switched and protected externally.
Installation and operation
- The blower can be mounted in any orientation, but the motor cooling air path must remain unobstructed.
- Inlet and outlet connections are threaded or flanged per the specific variant; mating parts must be rated for the maximum pressure and temperature.
- For vacuum duty, the exhaust must be piped away or fitted with a silencer to avoid backpressure and noise.
- The PDF digest contains no detailed installation or maintenance sections; refer to the full instruction manual for torque values, clearances, and service intervals.
Integration & Operating Notes
The 2BH7310 is available with different winding configurations; connecting a 230 V Δ motor to 400 V Y or vice versa will cause immediate damage. Verify the nameplate against the supply and use the correct Δ/Y link bars as shown in the terminal box diagram.
Operating above the maximum differential pressure will cause overheating, increased noise, and potential mechanical failure. Install a pressure relief valve or vacuum breaker set to these limits, especially when the blower can dead-head against a closed valve.
The motor is fan-cooled; mounting in a confined space or with the fan intake blocked will lead to overheating and reduced service life. Maintain at least the minimum clearance specified in the manual and avoid recirculating hot exhaust air.
The blower has no built-in thermal protection; an external overload relay or VFD with motor thermal model must be set to the rated current (e.g., 4.0 A Δ at 60 Hz) to prevent winding damage during stall or high-temperature operation.
Dust buildup on the impeller causes imbalance and reduces performance. The service interval depends on the process air cleanliness; in dusty environments, check monthly and clean with compressed air or a soft brush. Replace the inlet filter element when pressure drop becomes noticeable.
Selection & Integration Q&A
Choose the 2BH7310 when your process requires up to 360 mbar pressure or -340 mbar vacuum and a motor power around 0.94 kW at 50 Hz. The 2BH7210 and 2BH7220 are smaller siblings with lower power and pressure limits; select them only if the duty point falls within their lower curves, saving cost and space.
The motor is available in 200–240 V (50 Hz) or 220–275 V Δ / 380–480 V Y (60 Hz) versions, drawing up to 4.0 A in Δ at 60 Hz. Use a motor protection switch or VFD rated for the supply voltage and set to the nameplate current. For VFD operation at 87 Hz, ensure the motor is inverter-rated and the drive is configured for the correct V/Hz ratio.
The data sheet does not specify an ambient temperature range, but the motor is fan-cooled and relies on free air circulation. For outdoor installation, provide a weatherproof enclosure that does not restrict cooling air. In high-temperature environments, derate the motor or provide additional ventilation to keep winding temperature within Class F limits.
The base delivery includes the blower only; inlet/outlet silencers, filters, flexible connectors, pressure relief valves, and motor protection devices must be ordered separately. Maintenance parts such as filter elements and gaskets are also not included. Refer to the spare parts list for the specific variant.