Elmo Rietschle 2BH7530
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7530

Elmo Rietschle 2BH7530 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -590 mbar, Motor power 7.5 kW, Noise level 79 dB.

The 2BH7530 is a side-channel blower with an integrated frequency converter (VFD type 2FC4752-1□□00), configured for 345 V / 87 Hz delta operation from a 380–480 V mains. It delivers up to 760 mbar differential pressure at 7.5 kW, distinguishing it from smaller G-BH7 siblings by its higher pressure capability and built-in variable-speed drive. It is intended for pressure or vacuum duty in process systems where speed control and compact integration are required.

Max. differential pressure
-590 mbar
Motor power
7.5 kW
Noise level
79 dB
Weight
80 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7530 Current 7.570-6108016.2400
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -590 mbar (100 Hz)
87 Hz: -610 mbar · 60 Hz: -690 mbar · 50 Hz: -680 mbar
Motor power 8.8 kW (100 Hz)
87 Hz: 7.5 kW
Noise level 79 dB(A) (100 Hz)
87 Hz: 79 dB(A) · 60 Hz: 70 dB(A) · 50 Hz: 66 dB(A)
Motor connection mfr delta
Order No. mfr 2BH7530-0AK76-1
Max. differential pressure (vacuum) mfr -530 mbar (37 Hz)
Max. differential pressure (vacuum) mfr -680 mbar (50 Hz)
Max. differential pressure (vacuum) mfr -690 mbar (60 Hz)
Max. differential pressure (vacuum) mfr -610 mbar (87 Hz)
Max. differential pressure (alt 100 Hz) mfr 600 mbar (100 Hz)
Max. differential pressure (alt 87 Hz) mfr 760 mbar (87 Hz)
Max. differential pressure (alt 60 Hz) mfr 900 mbar (60 Hz)
Max. differential pressure (alt 50 Hz) mfr 950 mbar (50 Hz)
Dimensions, Weight & Mechanical Design
Weight 80 kg
Weight approx. mfr 50 kg
Electrical, Power & Drive Specifications
Current 16.2 A (100 Hz (U connection))
87 Hz (delta connection): 14.4 A
Frequency 100 Hz
Power supply 3~ 50/60 Hz
Voltage 400 V (100 Hz (U connection))
87 Hz (delta connection): 400 V
Rated voltage/frequency set point mfr 345 V / 87 Hz V / Hz
Frequency converter pulse frequency mfr 4 kHz
Mains voltage minimum mfr 380 V
Rated motor voltage mfr 400 V
Max. motor current mfr 8,8 A
VFD rated mains voltage mfr 400V (-15%) ... 480V (+10%) V
VFD rated mains current mfr 7,5 A
VFD typical motor power mfr 7,5 kW
VFD max. motor current mfr 14,8 A
Rated motor current mfr 16,2 A
Rated motor voltage mfr 400 V (87 Hz)
Rated motor current mfr 14,4 A (87 Hz)
Rated voltage frequency set point mfr 345 V (87 Hz)
Mains voltage mfr 380 V (minimum)
Frequency (alt var) mfr 50 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 79 dB(A)
Sound pressure level mfr 72/74 dB(A) (50 Hz / 60 Hz)
Sound pressure level mfr 72 dB(A) (G17)
Sound pressure level (with G17) mfr 72/74 dB(A) (50 Hz / 60 Hz)
Sound pressure level (with G17) mfr 74 dB(A)
Sound pressure level mfr 67 dB(A) (37 Hz)
Sound pressure level mfr 66 dB(A) (50 Hz)
Sound pressure level mfr 70 dB(A) (60 Hz)
Sound pressure level mfr 79 dB(A) (87 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Do not exceed 8.8 A motor current at the VFD output

The motor’s maximum current is 8.8 A, while the VFD can deliver up to 14.8 A. The drive must be parameterized with a motor current limit of 8.8 A to prevent winding overheating and insulation degradation, especially at low speeds where cooling is reduced.

Technical Data Sheet — G-BH7 2BH7530, extra specs
Electrical
Maintain mains voltage within 400 V −15% to 480 V +10%

The integrated VFD is rated for this window. Operation outside it may cause undervoltage or overvoltage trips, and the 345 V / 87 Hz set point assumes a nominal 400 V supply. A step-up or step-down transformer may be required for other mains.

Technical Data Sheet — G-BH7 2BH7530, extra specs
Control & I/O
Configure VFD motor data before first start

The VFD must be set for delta connection, 87 Hz base frequency, 345 V rated voltage and 8.8 A current limit. Starting without these settings risks overload trips or motor damage. Use the VFD manual for the parameter list and startup procedure.

Technical Data Sheet — G-BH7 2BH7530; VFD manual 2FC4xxx
Process Limits
Never exceed 760 mbar differential pressure

Exceeding 760 mbar may cause motor overload, excessive temperature rise or mechanical damage. Install a pressure relief valve or monitor differential pressure and interlock the drive to trip if the limit is approached.

Technical Data Sheet — G-BH7 2BH7530, extra specs
Maintenance
Inspect and clean the impeller and filter periodically

Dust buildup on the impeller and inlet filter reduces performance and can cause imbalance. The service interval depends on the process air cleanliness; check at least every 2000 hours or more frequently in dusty environments. Refer to the operating manual for detailed procedures.

Technical Data Sheet — G-BH7 2BH7530; general G-BH7 manual

Selection & Integration Q&A

When should I choose the 2BH7530 instead of a smaller G-BH7 sibling like the 2BH7210 or 2BH7220?

Choose the 2BH7530 when your process requires up to 760 mbar differential pressure and 7.5 kW motor power. The smaller siblings offer lower pressure and power; select them only if your duty point falls within their lower limits. The integrated VFD on the 2BH7530 also provides speed control without a separate cabinet drive.

What are the requirements for the mains supply and upstream protection for the integrated VFD?

The VFD requires a 3-phase supply of 400 V (−15%) to 480 V (+10%), 50/60 Hz, with a rated mains current of 7.5 A. Provide a circuit breaker or fuses sized to the VFD’s input current and consider a line reactor if the supply is prone to transients.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower with integrated VFD but typically excludes inlet/outlet silencers, filters, flexible connectors, and a pressure relief valve. These must be ordered separately. Maintenance kits such as impeller seals and bearings are available as spare parts; refer to the spare parts list for part numbers.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7530 side channel blower (EN)
Datasheet ·325,3 КБ ·2 pp.
View PDF