Elmo Rietschle 2BH7630
Elmo Rietschle 2BH7630 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -500 mbar, Motor power 16 kW, Noise level 75…78 dB.
The 2BH7630 is a side-channel blower from the G-BH7 e series, supplied with an integrated frequency converter for variable-speed operation. It delivers up to 720 mbar differential pressure in pressure mode and 500 mbar in vacuum mode at 50 Hz, with a 12.1 kW rated motor. This modification is the higher-capacity unit within the series, intended for continuous industrial vacuum or pressure duty where flow and pressure must be electronically controlled.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7630 Current | 16 | 80 | -500 | 121 | 29 | 400 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
Full specifications
| Max. differential pressure | -500 mbar |
| Motor power | 16.0 kW |
| Noise level | 80 dB(A) 50 Hz / 60 Hz: 75/78 dB(A) |
| Max differential pressure vacuum mfr | 500 mbar (50 Hz) |
| Motor type mfr | 3~ 50/60 Hz, IP55, Insulation material class F, |
| Max. differential pressure (Pressure) (alt var) mfr | 720 mbar |
| Weight | 121 kg |
| Weight approx. mfr | 123 kg |
| Current | 29.0 A |
| Frequency | 100 Hz |
| Power supply | 3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09 |
| Voltage | 400 V |
| Rated mains voltage mfr | 400 V (50 Hz) |
| Rated mains voltage mfr | 480 V (60 Hz) |
| Rated motor current mfr | 29.0 A (400 V) |
| Rated motor current mfr | 27.4 A (380 V) |
| Max motor current mfr | 10.2 A (50 Hz) |
| Typical motor power mfr | 14.0 kW (50 Hz) |
| Rated motor power mfr | 12.1 kW (50 Hz) |
| Mains frequency mfr | 50/60 Hz |
| Rated motor current mfr | 29.0 A |
| Protection rating | IP55 |
| Sound pressure level mfr | 80 dB(A) (50 Hz) |
| Sound pressure level mfr | 85 dB(A) (60 Hz) |
| Sound pressure level mfr | 80 dB(A) |
Description
Construction and series positioning
- The 2BH7630 is a regenerative ring blower with a cast housing and an impeller running in a side channel; the compression effect is generated by repeated acceleration and deceleration of the gas between impeller blades and the channel wall.
- Unlike the smaller sibling models 2BH721, 2BH7210, 2BH722 and 2BH7220, this model is the largest in the G-BH7 range and is distinguished by its integrated frequency converter (variants 2FC4152-1□□00 through 2FC4223-1□□00).
- The motor is rated 16.0 kW with IP55 protection and class F insulation, making it suitable for dusty or damp industrial environments.
Operating behavior
- At 50 Hz the maximum differential pressure is 720 mbar in pressure mode and 500 mbar in vacuum mode; these limits define the usable operating envelope and must not be exceeded.
- The blower is designed for 50/60 Hz mains supply (400 V / 480 V), with a rated current of 29.0 A at 400 V. The frequency converter allows speed adjustment, which in turn varies flow and pressure along the machine's characteristic curve.
- Sound pressure level is 80 dB(A) at 50 Hz and 85 dB(A) at 60 Hz, so acoustic attenuation or hearing protection may be required depending on installation.
Installation and control
- The integrated frequency converter provides electronic speed control; the exact control interface (analog setpoint, digital inputs, communication options) is defined in the technical data sheet for the specific converter variant.
- The blower must be mounted on a flat, rigid surface using the designated mounting points; the 123 kg weight requires appropriate lifting equipment and vibration isolation if sensitive equipment is nearby.
- Electrical connection must be made by qualified personnel according to the wiring diagram in the technical data sheet, observing the rated currents and protection class.
Integration & Operating Notes
The motor is rated for 400 V at 50 Hz and 480 V at 60 Hz, with a rated current of 29.0 A at 400 V. Ensure the supply transformer and protection devices can handle the starting current and continuous load; undersized supply will cause voltage drop and converter faults.
The integrated frequency converter (variants 2FC4152-1□□00 to 2FC4223-1□□00) must be configured with the motor data of the 2BH7630. Incorrect parameterization can lead to overload, overheating or insufficient pressure; always verify the converter settings against the data sheet before commissioning.
The maximum differential pressure is 720 mbar in pressure mode and 500 mbar in vacuum mode at 50 Hz. Operating beyond these limits will cause overheating and may damage the impeller or motor; install pressure relief or monitoring to keep the process within the envelope.
The motor and frequency converter dissipate heat; restricted airflow will cause overheating and reduced service life. Maintain the minimum clearance specified in the data sheet and avoid recirculating hot exhaust air into the intake.
Selection & Integration Q&A
Choose the 2BH7630 when you need higher pressure (up to 720 mbar) and flow than the smaller siblings can provide. The 2BH7220 is limited to lower performance; the 2BH7630 is the largest in the series and includes an integrated frequency converter for speed control.
The blower requires a 400 V (50 Hz) or 480 V (60 Hz) supply with rated current of 29.0 A at 400 V. Use motor protection rated for the starting current and ensure the supply can handle the 16.0 kW continuous load. The integrated frequency converter must be configured for the motor data.
Regular maintenance includes checking the impeller for debris, inspecting the frequency converter cooling, and verifying electrical connections. The base delivery does not include external filters, silencers, or flexible connectors; these must be ordered separately based on the application.