Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH7610 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Side channel blower G-BH 7 N, data sheet 2BH7 610-0A, with IE3 motors; covers sizes 1 and 2, 50 Hz and 60 Hz, various three-phase voltage variants and alternate-voltage motor options (code 2BH7…-..□.□-2).

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH7610-0AK11-2, size 1
Voltage 190-210 D V p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Current 9,9 D A p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Power 2,5 kW p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Vacuum -370 mbar p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Pressure 400 mbar p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Sound pressure level 63 dB(A) p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Weight 41 kg p.2 ↗ 2BH7610-0AK11-2, size 1
Efficiency class IE3 p.2 ↗ 2BH7610-0AK11-2, size 1, 50 Hz
Rated frequency 60 Hz p.2 ↗ 2BH7610-0AK11-2, size 1
Voltage 190-210 / 380-420 V p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Current 12,0 / A p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Power 3,0 kW p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Vacuum -370 mbar p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Pressure 350 mbar p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Sound pressure level 68 dB(A) p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Efficiency class IE3 p.2 ↗ 2BH7610-0AK11-2, size 1, 60 Hz
Rated frequency 50 Hz p.2 ↗ 2BH7610-0AK21-2, size 2
Voltage 190-210 V p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Current 13,3 A p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Power 3,5 kW p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Vacuum -370 mbar p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Pressure 480 mbar p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Sound pressure level 67 dB(A) p.2 ↗ 2BH7610-0AK21-2, size 2, 50 Hz
Weight 45 kg p.2 ↗ 2BH7610-0AK21-2, size 2

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗
  • Voltage tolerance for three-phase motors: ± 10 % p.2 ↗
  • Frequency tolerance: ± 2 % maximum p.2 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series / type: side channel blower
5-7 p.2 ↗ 610 Size designation (G-BH 7 N, data sheet 2BH7 610-0A)
8-9 p.2 ↗ -0A Variant / generation code

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7610-0AK11-2 p.2 ↗ 2BH7610-0AK11-2 size 1, 50/60 Hz, 190-210 V IE3
2BH7610-0AK21-2 p.2 ↗ 2BH7610-0AK21-2 size 2, 50/60 Hz, 190-210 V / 380-420 V IE3
2BH7610-0AK16-2 p.2 ↗ 2BH7610-0AK16-2 size 1, 50/60 Hz, 220-240 V / 380-420 V / 440-480 V IE3
2BH7610-0AK26-2 p.2 ↗ 2BH7610-0AK26-2 size 2, 50/60 Hz, 220-240 V / 380-420 V / 440-480 V IE3
2BH7610-0AQ13-2 p.2 ↗ 2BH7610-0AQ13-2 size 1, 50/60 Hz, 500 V / 575 V IE3
2BH7610-0AQ23-2 p.2 ↗ 2BH7610-0AQ23-2 size 2, 50/60 Hz, 500 V / 575 V IE3
2BH7610-0AQ17-2 p.2 ↗ 2BH7610-0AQ17-2 size 1, 50/60 Hz, 440-480 V IE3
2BH7610-0AQ27-2 p.2 ↗ 2BH7610-0AQ27-2 size 2, 50/60 Hz, 380-420 V / 660-725 V / 440-480 V / 460 V IE3
2BH7610-0AQ16-2 p.2 ↗ 2BH7610-0AQ16-2 size 1, 50/60 Hz, 440-480 V IE3
2BH7610-0AQ26-2 p.2 ↗ 2BH7610-0AQ26-2 size 2, 50/60 Hz, 440-480 V IE3