Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH7630 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH7 630-0N, G-BH 7 N side channel blower with IE3 motors; covers 50 Hz and 60 Hz operation, single-stage (1) and two-stage (2) variants, and multiple voltage/connection variants (190-210 V, 200 V, 220-240 V, 380-420 V, 440-480 V, 500 V, 575 V, 660-725 V).

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH7630-0NK71-2, 1-stage
Voltage 190-210 D V p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Current 23,5 D A p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Power 6,3 kW p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Vacuum -680 mbar p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Pressure 900 mbar p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Sound level 64 dB(A) p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Weight 91 kg p.2 ↗ 2BH7630-0NK71-2, 1-stage
Efficiency class IE3 p.2 ↗ 2BH7630-0NK71-2, 50 Hz, 1-stage
Rated frequency 60 Hz p.2 ↗ 2BH7630-0NK71-2, 1-stage
Voltage 190-210 / 380-420 V p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Current 27,6 / A p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Power 7,3 kW p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Vacuum -650 mbar p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Pressure 810 mbar p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Sound level 66 dB(A) p.2 ↗ 2BH7630-0NK71-2, 60 Hz, 1-stage
Power 8,6 kW p.2 ↗ 2BH7630-0NK61-2, 50 Hz, 2-stage
Vacuum -680 mbar p.2 ↗ 2BH7630-0NK61-2, 50 Hz, 2-stage
Pressure 1050 mbar p.2 ↗ 2BH7630-0NK61-2, 50 Hz, 2-stage
Weight 100 kg p.2 ↗ 2BH7630-0NK61-2, 2-stage
Power 9,9 kW p.2 ↗ 2BH7630-0NK61-2, 60 Hz, 2-stage
Vacuum -650 mbar p.2 ↗ 2BH7630-0NK61-2, 60 Hz, 2-stage
Pressure 1060 mbar p.2 ↗ 2BH7630-0NK61-2, 60 Hz, 2-stage
Protection class IP 55 p.1 ↗ standard motors
Insulation class F p.1 ↗ standard motors

Operating Limits

  • Max suction and ambient temperature for stated total pressure differences: 25 °C p.1 ↗
  • Voltage tolerance for three-phase motors: +/-10 % p.2 ↗
  • Frequency tolerance: +/- 2 % maximum p.2 ↗
  • Protection category: IP 55 p.1 ↗
  • Insulation class: F p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series / type: side channel blower G-BH 7 N
5-8 p.2 ↗ 630-0N Size / model designation
field 1 p.2 ↗ K / Q Motor voltage variant group (K = 190-210 V / 200 V variants; Q = 220-240 V / 380-420 V / 440-480 V / 500 V / 575 V variants)
field 2 p.2 ↗ 1 / 2 Number of stages (1 = single-stage, 2 = two-stage)
field 3 p.2 ↗ □ Voltage / connection code (e.g. 1, 6, 7, 3, 4, 5, 8, 9, 0, 2, 6, 7, 6, 6, 7, 7, 6, 6)
field 4 p.2 ↗ □ Motor variant / efficiency class (IE3 or NP)
suffix p.2 ↗ -2 Design revision / generation

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7630-0NK71-2 p.2 ↗ 2BH7630-0NK71-2 50 Hz, 190-210 V D, 1-stage, IE3 Order No. printed in table
2BH7630-0NK61-2 p.2 ↗ 2BH7630-0NK61-2 50 Hz, 190-210 V D, 2-stage, IE3 Order No. printed in table
2BH7630-0NK76-2 p.2 ↗ 2BH7630-0NK76-2 50 Hz, 220-240 V D / 380-420 V Y, 1-stage, IE3 Order No. printed in table
2BH7630-0NK66-2 p.2 ↗ 2BH7630-0NK66-2 50 Hz, 220-240 V D / 380-420 V Y, 2-stage, IE3 Order No. printed in table
2BH7630-0NQ73-2 p.2 ↗ 2BH7630-0NQ73-2 50 Hz, 500 V Y, 1-stage, IE3 Order No. printed in table
2BH7630-0NQ63-2 p.2 ↗ 2BH7630-0NQ63-2 50 Hz, 500 V Y, 2-stage, IE3 Order No. printed in table
2BH7630-0NQ77-2 p.2 ↗ 2BH7630-0NQ77-2 60 Hz, 440-480 V D, 1-stage, IE3 Order No. printed in table
2BH7630-0NQ67-2 p.2 ↗ 2BH7630-0NQ67-2 50 Hz, 380-420 V D / 660-725 V Y, 2-stage, IE3 Order No. printed in table
2BH7630-0NQ76-2 p.2 ↗ 2BH7630-0NQ76-2 60 Hz, 440-480 V Y, 1-stage, IE3 Order No. printed in table
2BH7630-0NQ66-2 p.2 ↗ 2BH7630-0NQ66-2 60 Hz, 440-480 V Y, 2-stage, IE3 Order No. printed in table