Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 630-0N: side channel blower with integrated frequency converter (VFD). Covers 50 Hz and 60 Hz operation, 400 V and 380 V mains, delta connection, VFD types G and H, and order numbers 2BH7630-0N361-2, -0N371-2, -0N366-2, -0N376-2, -0NK66-2, -0NK76-2.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Frequency | 50 Hz p.2 ↗ | 2BH7630-0N361-2, 400 V |
| Rated voltage | 400 V p.2 ↗ | 2BH7630-0N361-2, 50 Hz |
| Rated motor current | 29,0 A p.2 ↗ | 2BH7630-0N361-2, 50 Hz, 400 V |
| Rated motor power | 16,0 kW p.2 ↗ | 2BH7630-0N361-2, 50 Hz, 400 V |
| Max. differential pressure, vacuum | -560 mbar p.2 ↗ | 2BH7630-0N361-2, 50 Hz |
| Max. differential pressure, pressure | 390 mbar p.2 ↗ | 2BH7630-0N361-2, 50 Hz |
| Sound pressure level | 80 dB(A) p.2 ↗ | 2BH7630-0N361-2, 50 Hz |
| Weight | 118 kg p.2 ↗ | 2BH7630-0N361-2, 50 Hz |
| Frequency | 100 Hz p.2 ↗ | 2BH7630-0N361-2, 400 V |
| Rated motor current | 22,0 A p.2 ↗ | 2BH7630-0N371-2, 100 Hz, 400 V |
| Rated motor power | 12,1 kW p.2 ↗ | 2BH7630-0N371-2, 100 Hz, 400 V |
| Max. differential pressure, vacuum | -560 mbar p.2 ↗ | 2BH7630-0N371-2, 100 Hz |
| Max. differential pressure, pressure | 320 mbar p.2 ↗ | 2BH7630-0N371-2, 100 Hz |
| Sound pressure level | 80 dB(A) p.2 ↗ | 2BH7630-0N371-2, 100 Hz |
| Weight | 110 kg p.2 ↗ | 2BH7630-0N371-2, 100 Hz |
| Rated voltage | 380 V p.2 ↗ | 2BH7630-0N366-2, 85 Hz |
| Rated motor current | 27,4 A p.2 ↗ | 2BH7630-0N366-2, 85 Hz, 380 V |
| Rated motor power | 14,0 kW p.2 ↗ | 2BH7630-0N366-2, 85 Hz, 380 V |
| Max. differential pressure, vacuum | -590 mbar p.2 ↗ | 2BH7630-0N366-2, 85 Hz |
| Max. differential pressure, pressure | 990 mbar p.2 ↗ | 2BH7630-0N366-2, 85 Hz |
| Sound pressure level | 80 dB(A) p.2 ↗ | 2BH7630-0N366-2, 85 Hz |
| Weight | 120 kg p.2 ↗ | 2BH7630-0N366-2, 85 Hz |
| Rated voltage | 400 V p.2 ↗ | 2BH7630-0NK66-2, 85 Hz, delta |
| Rated motor current | 26,0 A p.2 ↗ | 2BH7630-0NK66-2, 85 Hz, 400 V delta |
| Rated motor power | 14,0 kW p.2 ↗ | 2BH7630-0NK66-2, 85 Hz, 400 V delta |
Operating Limits
- Max. ambient/suction temperature for stated total pressure differences: 25 °C p.1 ↗
- Min. mains voltage for frequency converter: 380 V p.1 ↗
- Min. pulse frequency for performance curves: 4 kHz p.1 ↗
- Protection class: IP55 p.2 ↗
- Insulation material class: F p.2 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-4 p.2 ↗ | 2BH7 | Series G-BH7 side channel blower |
| 5-8 p.2 ↗ | 630-0N | Size / type 2BH7 630-0N |
| suffix p.2 ↗ | 361-2 | Variant: 100 Hz, 400 V, VFD type H |
| suffix p.2 ↗ | 371-2 | Variant: 100 Hz, 400 V, VFD type G |
| suffix p.2 ↗ | 366-2 | Variant: 85 Hz, 380 V, VFD type G |
| suffix p.2 ↗ | 376-2 | Variant: 85 Hz, 380 V, VFD type G |
| suffix p.2 ↗ | NK66-2 | Variant: 85 Hz, 400 V delta, VFD type G |
| suffix p.2 ↗ | NK76-2 | Variant: 85 Hz, 400 V delta, VFD type G |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH7630-0N361-2 p.2 ↗ | 2BH7630-0N361-2 | H | 100 Hz, 400 V | VFD type H |
| 2BH7630-0N371-2 p.2 ↗ | 2BH7630-0N371-2 | G | 100 Hz, 400 V | VFD type G |
| 2BH7630-0N366-2 p.2 ↗ | 2BH7630-0N366-2 | G | 85 Hz, 380 V | VFD type G |
| 2BH7630-0N376-2 p.2 ↗ | 2BH7630-0N376-2 | G | 85 Hz, 380 V | VFD type G |
| 2BH7630-0NK66-2 p.2 ↗ | 2BH7630-0NK66-2 | G | 85 Hz, 400 V delta | VFD type G |
| 2BH7630-0NK76-2 p.2 ↗ | 2BH7630-0NK76-2 | G | 85 Hz, 400 V delta | VFD type G |
Related models
Elmo Rietschle 2BH721
Elmo Rietschle 2BH7210
Elmo Rietschle 2BH722
Elmo Rietschle 2BH7220
Elmo Rietschle 2BH731
Elmo Rietschle 2BH7310
Elmo Rietschle 2BH732
Elmo Rietschle 2BH7320
Elmo Rietschle 2BH741
Elmo Rietschle 2BH7410
Elmo Rietschle 2BH742
Elmo Rietschle 2BH7420
Elmo Rietschle 2BH751
Elmo Rietschle 2BH7510
Elmo Rietschle 2BH752
Elmo Rietschle 2BH7520
Elmo Rietschle 2BH753
Elmo Rietschle 2BH7530
Elmo Rietschle 2BH7610
Elmo Rietschle 2BH7620
Elmo Rietschle 2BH7630