Elmo Rietschle 2BH721
Elmo Rietschle 2BH721 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 1 kW, Noise level 63 dB.
The 2BH721 is a three-phase side-channel blower in the G-BH7 series, fitted with an IE3 efficiency motor and rated 1.0 kW at 50 Hz / 1.1 kW at 60 Hz. It delivers up to 290 mbar pressure and -230 mbar vacuum at 50 Hz (420 mbar / -300 mbar at 60 Hz), distinguishing it from lower-output siblings such as the 2BH722. It serves as a compact pressure/vacuum source for pneumatic conveying, aeration, or holding duties where a small, high-efficiency ring blower is required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH721 Current | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -230 mbar (50 Hz) 60 Hz: -300 mbar |
| Motor power | 1.0 kW (50 Hz) 60 Hz: 1.1 kW |
| Noise level | 59 dB(A) (50 Hz) 60 Hz: 63 dB(A) |
| Ultimate pressure | 290 mbar (50 Hz) 60 Hz: 420 mbar |
| Max. differential pressure vacuum mfr | -300 mbar (60 Hz) |
| Efficiency mfr | IE3 (60 Hz) |
| Approval mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Vacuum mfr | -230 mbar (50 Hz) |
| Efficiency mfr | IE3 (50 Hz) |
| Vacuum mfr | -300 mbar (60 Hz) |
| Efficiency mfr | NP (60 Hz, 200 V YY) |
| Order No. mfr | 2BH7210-0AK31-1 |
| Certification mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Weight | 21 kg (50 Hz) |
| Current | 4.2 A (50 Hz) 60 Hz: 4.8 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 V |
| Voltage connection mfr | 460 Δ V (60 Hz) |
| Phase mfr | 3~ |
| Voltage tolerance mfr | ±10 % |
| Frequency tolerance mfr | ±2 % |
| Rated frequency mfr | 60 Hz (60 Hz) |
| Voltage (alt 60 Hz) mfr | 380-420 V (60 Hz) |
| Current (alt 60 Hz) mfr | 2.4 A (60 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 63 dB(A) (60 Hz) |
| Sound pressure level mfr | 59 dB(A) (50 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with an IE3-class three-phase induction motor, IP55 protection and class F insulation.
- Within the G-BH7 family, the 2BH721 sits above the 2BH722/2BH7220 and below the 2BH731 in output; it is the IE3-efficiency variant of the 2BH7210 platform.
- Dual-frequency design: 50 Hz (380–420 V Δ / 660–725 Y) and 60 Hz (460 V Δ) windings, with ±10 % voltage and ±2 % frequency tolerance.
Performance behaviour
- At 50 Hz the machine reaches 290 mbar differential pressure and -230 mbar vacuum; at 60 Hz these rise to 420 mbar and -300 mbar respectively.
- Motor current is 2.1 A in delta at 50 Hz (1.2 A in star) and 2.1 A at 60 Hz, with absorbed power of 1.0 kW (50 Hz) and 1.1 kW (60 Hz).
- Sound pressure level is 63 dB(A) at 60 Hz; no curve points were supplied, so the pressure/flow characteristic must be taken from the manufacturer's performance curve for the 2BH7210 platform.
Electrical and compliance
- Three-phase 50/60 Hz supply, IE3 efficiency, UL 1450 and CAN/CSA C22.2 No. 68-09 approval (certificate E225239).
- No application-specific certificates or process-media data are listed; media compatibility must be confirmed against the series documentation.
Integration & Operating Notes
The IE3 motor is wound for 380–420 V Δ / 660–725 Y at 50 Hz and 460 V Δ at 60 Hz. Operating outside the stated tolerances risks overheating, loss of efficiency and reduced bearing life; verify the actual site voltage and frequency before connecting, especially on 60 Hz grids where only the 460 V delta connection is specified.
Because the blower is a three-phase machine with no integrated starter, the panel must include overload protection sized to the 2.1 A delta current and a phase-sequence check. Running the blower backwards reverses the air flow direction and can overload the motor; confirm rotation at first start before coupling to the process.
The IP55 motor and class F insulation allow installation in dusty or damp industrial environments, but the blower still needs a firm, level base and unobstructed intake/exhaust. Ensure sufficient clearance around the motor fan cowl for cooling air, since the 63 dB(A) sound level and 1.1 kW losses are dissipated convectively.
The base unit is supplied without power cable, starter or process connections; these must be ordered separately. Scheduled maintenance is limited to bearing inspection and cleaning of the impeller/side channel; the manual digest provides no fixed interval, so follow the series service schedule and check bearings at each shutdown.
Selection & Integration Q&A
Pick the 2BH721 when you need roughly 1.0–1.1 kW and up to 290/420 mbar with IE3 efficiency. The 2BH722 is a lower-output sibling; the 2BH731 is larger. Choose the 2BH7210 if IE3 is not required.
A three-phase 50/60 Hz supply within ±10 % voltage and ±2 % frequency, a contactor and overload set to 2.1 A (delta), and a phase-sequence check. No starter or cable is included, so these are panel-side scope.
Mount on a firm level base with cooling-air clearance around the IP55 motor. Continuous duty is limited by the 290 mbar (50 Hz) / 420 mbar (60 Hz) differential-pressure ceiling; blocked flow raises current above 2.1 A and must be avoided.
Order power cable, starter and process flanges separately. Maintenance is bearing inspection and impeller/side-channel cleaning; no fixed interval is given in the digest, so follow the G-BH7 series schedule and check at each shutdown.