Elmo Rietschle 2BH732
Elmo Rietschle 2BH732 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 480 mbar, Motor power 1.6 kW, Noise level 60 dB.
The 2BH732 is a side-channel (regenerative ring) blower built around an IE3-class 3-phase motor, supplied in the 2BH7320-0AK41-1 order variant with 190–210 Δ / 380–420 Y V windings for 50 and 60 Hz operation. It delivers up to 480 mbar differential pressure and −440 mbar vacuum at 60 Hz from a 1.6 kW, 33 kg package, positioning it as the larger frame in the 2BH72x family. It serves as a compact pressure/vacuum source for pneumatic conveying, aeration, and holding-duty process air in machine-integrated systems.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH732 Current | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | 440 mbar (50 Hz, vacuum) 60 Hz, vacuum: 510 mbar · 50 Hz, pressure: 480 mbar · 60 Hz, pressure: 480 mbar |
| Motor power | 1.3 kW (50 Hz) 60 Hz: 1.6 kW |
| Noise level | 60 dB (50 Hz, IE3) 60 Hz, IE3: 64 dB · 60 Hz, NP: 64 dB |
| Max. differential pressure vacuum mfr | -440 mbar (60 Hz) |
| Order No. mfr | 2BH7320-0AK41-1 |
| Vacuum mfr | -440 mbar (50 Hz) |
| Efficiency mfr | IE3 (50 Hz) |
| Vacuum mfr | -510 mbar (60 Hz) |
| Efficiency mfr | NP (60 Hz) |
| Weight | 33 kg |
| Current | 5.6 A (50 Hz, 190-210 V) 60 Hz, 190-210 V: 6.3 A · 60 Hz, 380-420 V: 3.2 A |
| Frequency | 50/60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Efficiency class mfr | IE3 |
| Protection rating | IP55 |
| Sound pressure level mfr | 64 dB(A) |
| Sound pressure level mfr | 60 dB(A) (50 Hz) |
| Sound pressure level mfr | 64 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel blower with an integrated IE3 3-phase motor; the 2BH732 is the higher-capacity frame relative to the 2BH721/2BH722 siblings in the same G-BH7 series.
- The 2BH7320-0AK41-1 variant is one of several winding/order-number configurations of the 2BH7 320 type; it is the 190–210 Δ / 380–420 Y V build, not the 200 Y, 230/460 Y, 500 Y, 575 Y, or 690 Y variants listed in the data sheet.
- Enclosure is IP55 with insulation class F; the type carries UL 1450 and CAN/CSA C22.2 No. 68-09 recognition (certificate E225239).
Working range and behavior
- Maximum differential pressure is 480 mbar in pressure mode and −440 mbar in vacuum mode, both quoted at 60 Hz; the 50 Hz build is rated 1.6 kW.
- Current draw at 60 Hz is 5.6 A. No digitized curve points were supplied, so the pressure/flow characteristic must be taken from the manufacturer's performance curves for this order number rather than interpolated here.
- Sound pressure level is 64 dB(A); unit mass is 33 kg.
Installation and operation
- The data sheet digest does not include wiring, piping, or commissioning sections; connection and control specifics must be taken from the full instruction manual for the 2BH7 320 type before installation.
- Because the motor is dual-voltage (Δ/Y), the winding link configuration must be set to match the actual supply before first start.
Integration & Operating Notes
The -0AK41-1 motor is dual-voltage (190–210 V Δ / 380–420 V Y). Energizing with incorrect terminal links will over-flux or under-torque the IE3 motor; verify the link plate against the actual supply and record it at commissioning.
The 60 Hz current is 5.6 A; the motor-protection setting and cable sizing must be based on this value plus the installation method, not on the 50 Hz power rating alone. Confirm the 50 Hz current from the full manual if operating at 50 Hz.
These are the maximum differential pressures quoted at 60 Hz. Operating beyond them moves the blower off its stable side-channel characteristic and raises motor load and temperature; the working point must be checked against the published curve for this order number.
The attached data sheet digest contains no maintenance schedule, error codes, or spare-parts list. Bearing, filter, and seal service planning must be taken from the complete instruction manual for the 2BH7 320 type before the unit is put into continuous duty.
Selection & Integration Q&A
Choose the 2BH732 when the duty needs up to 480 mbar pressure or −440 mbar vacuum at 60 Hz and the 1.6 kW / 33 kg frame is acceptable. The 2BH721/2BH722 siblings are smaller frames; use them only if their published curves cover the required pressure at the required flow.
The -0AK41-1 build is wound 190–210 V Δ / 380–420 V Y at 50 and 60 Hz, drawing 5.6 A at 60 Hz. Set the terminal links for the actual line voltage, provide a motor-protection device set to the nameplate current, and confirm the IE3 motor's IP55 enclosure is not compromised by cable entries.
The data sheet lists only the blower and its order number; mating flanges, silencers, filters, flexible connectors, and power cable are not part of the base unit. The digest contains no maintenance schedule, so interval and spare-part planning must come from the full instruction manual.