Elmo Rietschle 2BH751
Elmo Rietschle 2BH751 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -340 mbar, Motor power 1.8 kW, Noise level 68 dB.
The 2BH751 is a side-channel blower from the G-BH7 series, driven by an IE3 efficiency-class motor and rated for continuous duty at 50/60 Hz. It delivers a maximum differential pressure of 420 mbar and is distinguished within the series by its IE3 motor and IP55 protection, making it suitable for vacuum or pressure duty in industrial processes. Its primary purpose is to provide oil-free, contactless air movement in systems requiring moderate pressure ratios and reliable, low-maintenance operation.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH751 Current | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -310 mbar (50 Hz) 60 Hz: -340 mbar · 60 Hz (NP variant): -340 mbar |
| Motor power | 1.8 kW (50 Hz) 60 Hz: 2.0 kW · 60 Hz (NP variant): 2.0 kW |
| Noise level | 62 dB (50 Hz) 60 Hz: 68 dB · 60 Hz (NP variant): 68 dB |
| Pumping speed | 360 m³/hour (50 Hz) 60 Hz: 330 m³/hour · 60 Hz (NP variant): 330 m³/hour |
| Order number mfr | 2BH7510-0AK11-1 |
| Efficiency mfr | IE3 (50 Hz) |
| Order No. mfr | 2BH7510-0AK11-1 |
| Efficiency mfr | IE3 (60 Hz) |
| Weight | 33 kg (50 Hz) 60 Hz: 33 kg |
| Current | 6.9 A (50 Hz) 60 Hz: 7.8 UU / 3.9 U A · 60 Hz (NP variant): 7.8 UU A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz · 60 Hz (NP variant): 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 UU / 380-420 U V · 60 Hz (NP variant): 200 UU V |
| Efficiency class mfr | IE3 |
| Power consumption at pump shaft mfr | 3.5 kW (50 Hz) |
| Power consumption at pump shaft mfr | 3.5 kW (60 Hz) |
| Rated current mfr | 7.8 UU / 3.9 U A (60 Hz) |
| Rated power mfr | 2.0 kW (60 Hz) |
| Ambient temperature limit | 25 degC |
| Protection rating | IP55 |
| Sound pressure level mfr | 62 dB(A) (50 Hz) |
| Sound pressure level mfr | 68 dB(A) (60 Hz) |
Description
Construction and series positioning
The 2BH751 (order number 2BH7510-0AK11-1) is a side-channel (regenerative) blower with an integrated IE3 motor. Unlike sibling models 2BH721 and 2BH722, which are earlier or lower-power variants, the 2BH751 is the higher-capacity unit in the G-BH7 series, offering a maximum differential pressure of 420 mbar and a shaft power consumption of 3.5 kW. The motor is wound for dual voltage/frequency operation (200 V YY / 230 V Δ / 400 V Y at 50 Hz; 230 V YY / 460 V Y at 60 Hz) and is rated IP55 with insulation class F, allowing operation in dusty or humid environments.
Behavior under load and media
No digitized curve points are available for this model, so performance must be derived from the stated maximum differential pressure and power. The blower is designed for oil-free, contactless operation, meaning no lubrication is required in the air path. The maximum differential pressure of 420 mbar applies at both 50 and 60 Hz, indicating that the pressure capability is not frequency-dependent within the stated range. Sound pressure level is 62 dB(A) at both frequencies, which is moderate for this class of blower.
Installation, connection, and control
The 2BH751 is typically mounted horizontally, but the manual may allow other orientations; refer to the installation instructions for specific mounting positions. Electrical connection must match the available supply: at 50 Hz, the motor can be connected in YY (200 V), Δ (230 V), or Y (400 V); at 60 Hz, YY (230 V) or Y (460 V). The terminal box provides IP55 protection when properly sealed. The blower is air-cooled by the motor fan; ensure unobstructed airflow around the motor. Control is via a direct-on-line starter or a variable frequency drive (VFD) if speed control is required, but note that VFD operation may require additional filtering to avoid bearing currents. The blower can be used for either vacuum or pressure duty by connecting the inlet or outlet to the process, respectively.
Integration & Operating Notes
The 2BH751 motor is dual-rated for 50 Hz and 60 Hz with different winding configurations. At 50 Hz, connect in YY for 200 V, Δ for 230 V, or Y for 400 V. At 60 Hz, connect in YY for 230 V or Y for 460 V. Incorrect connection will cause overheating or reduced performance. Verify the supply voltage and frequency before wiring, and ensure the terminal box is sealed to maintain IP55.
The motor is fan-cooled and relies on free airflow. Install the blower in a location with sufficient clearance for air intake and exhaust. Avoid enclosing the unit in a small, unventilated space. Ambient temperature should not exceed the motor's rated ambient (typically 40°C) unless derating is applied. Consult the manual for specific clearance dimensions.
Selection & Integration Q&A
Choose the 2BH751 when you need a maximum differential pressure of 420 mbar and a shaft power of 3.5 kW. The 2BH721 and 2BH722 are lower-capacity models in the series, suitable for lower pressure or flow requirements. The 2BH751 also features an IE3 motor for higher efficiency, which can reduce operating costs in continuous duty.
The motor is inverter-duty rated but requires a VFD with adjustable pulse frequency and a sine-wave filter or dv/dt filter to protect the motor insulation. Ensure the VFD is set to the correct V/f ratio and that the motor is configured for the actual supply voltage. Consult the motor manual for maximum cable length and grounding requirements.
The blower is rated for continuous duty (S1) at ambient temperatures up to 40°C. For higher ambient temperatures, derating may be required. Ensure adequate ventilation and avoid direct sunlight. The IP55 protection allows operation in dusty and humid environments, but the blower should not be submerged.
The base delivery includes the blower only. Optional accessories such as inlet filters, silencers, flexible connectors, and mounting feet are not included. Maintenance items like replacement bearings and seals are available as spare parts. A terminal box cover and cable gland are included, but power cables and fuses are not.