Elmo Rietschle 2BH7520
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7520

Elmo Rietschle 2BH7520 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -520 mbar, Motor power 4.3 kW, Noise level 77 dB.

The 2BH7520 is a side-channel blower with integrated frequency converter, configured for 400 V 50/60 Hz operation and delivering up to -520 mbar vacuum at 50 Hz. As the largest frame in the G-BH7 series, it is distinguished by its 5.0 kW rated power and factory-matched VFD, enabling speed control without external drive engineering. It serves as a central vacuum source in pneumatic conveying, drying, and pick-and-place systems requiring high differential pressure.

Max. differential pressure
-520 mbar
Motor power
4.3 kW
Noise level
77 dB
Weight
57 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7520 Current 4.377-520578.7400 V (-15%) … 480 V (+1
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -320 mbar (100 Hz, 400 V)
87 Hz, 345 V: -520 mbar
Motor power 5.0 kW (100 Hz, 400 V)
87 Hz, 345 V: 4.3 kW
Noise level 77 dB(A) (100 Hz)
87 Hz: 77 dB(A)
Max. differential pressure vacuum mfr -520 mbar (50 Hz)
Order No. mfr 2BH7520-0A321-1 (50 Hz)
Order No. mfr 2BH7520-0A326-1 (60 Hz)
Max. differential pressure vacuum mfr -490 mbar (60 Hz)
Motor connection mfr delta
Max. differential pressure vacuum mfr -560 mbar
Order No. mfr 2BH7520-0A371-1
Connection mfr delta
Performance curve tolerance mfr ± 10 %
Max. differential pressure (alt 100 Hz, 400 V) mfr 240 mbar (100 Hz, 400 V)
Max. differential pressure (alt 87 Hz, 345 V) mfr 380 mbar (87 Hz, 345 V)
Dimensions, Weight & Mechanical Design
Weight 57 kg (100 Hz)
87 Hz: 57 kg
Weight approx. mfr 71 kg
Electrical, Power & Drive Specifications
Current 9.8 A (100 Hz, 400 V)
87 Hz, 345 V: 8.7 A
Frequency 50/60 Hz (±6%)
Voltage 400 V (-15%) … 480 V (+10%) V
100 Hz: 400 V · 87 Hz: 345 V
Rated current mfr 16.2 A (60 Hz)
Rated power mfr 6.2 kW (60 Hz)
Frequency Converter rated mains voltage mfr 400 V -15% ... 480 V +10% V
Frequency Converter rated mains current mfr 10 A
Frequency Converter max. motor current mfr 5.6 A
Frequency Converter typical motor power mfr 3.0 kW
Frequency Converter fuse protection mfr 10 A
Frequency Converter type mfr 2FC4152-1 □ □00
Frequency Converter weight approx. mfr 3.3 kg
Rated voltage/frequency set point mfr 345 V (87 Hz)
Minimum mains voltage for frequency converter mfr 380 V
Pulse frequency minimum mfr 4 kHz
Rated motor voltage mfr 400 U V
Rated motor current mfr 16.2 U A
Rated motor power mfr 8.8 kW
Frequency converter mains voltage minimum mfr 380 V
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 69 dB(A) (50 Hz)
Sound pressure level mfr 71 dB(A) (60 Hz)
Sound pressure level mfr 81 dB(A)

Description

Construction and series positioning

Performance and load behavior

Installation, connection and control

Integration & Operating Notes

Electrical
Mains voltage must stay within 380–480 V for the integrated VFD

The frequency converter is rated for 400 V -15% … 480 V +10%, with an absolute minimum of 380 V. Operation below 380 V may cause undervoltage trips or erratic motor control; above 480 V risks overvoltage damage to the DC bus. Verify site voltage under load before commissioning.

Technical Data Sheet — G-BH7 2BH7520, Frequency Converter specifications
Control & I/O
Set VFD rated voltage/frequency to 345 V / 87 Hz before first run

The motor is delta-connected and the VFD must be parameterized to the factory set point of 345 V / 87 Hz. Running with default 400 V / 50 Hz settings will over-flux the motor and may trip on overcurrent. Confirm this parameter before enabling the drive.

Technical Data Sheet — G-BH7 2BH7520, Rated voltage/frequency set point
Process Limits
Maximum vacuum differs between 50 Hz and 60 Hz operation

At 50 Hz the maximum differential pressure is -520 mbar; at 60 Hz it is -490 mbar. Do not assume the higher frequency yields higher vacuum. Size the process for the frequency actually used, and note that VFD operation at 87 Hz set point may further alter the achievable vacuum.

Technical Data Sheet — G-BH7 2BH7520, Performance data
Mounting
VFD can be wall-mounted with adaptor 2FX16190ER00

If the VFD is not mounted directly on the blower, use the specified wall-mount adaptor. Ensure the mounting surface can carry the 3.3 kg VFD and that the motor cable length and shielding meet the VFD manufacturer’s EMC requirements.

Technical Data Sheet — G-BH7 2BH7520, Scope and variants
Maintenance
Check cooling-air paths and VFD heat sink at regular intervals

The blower and VFD are air-cooled. Dust or debris blocking the motor fan cover or VFD heat sink will cause overheating and premature trips. Inspect and clean these areas according to the site’s duty cycle; no specific interval is given in the supplied data sheet.

Technical Data Sheet — G-BH7 2BH7520, Protection class IP55

Selection & Integration Q&A

When should I choose the 2BH7520 instead of a smaller G-BH7 sibling like the 2BH7210 or 2BH7220?

Choose the 2BH7520 when the process requires up to -520 mbar vacuum at 50 Hz or -490 mbar at 60 Hz, at flow rates beyond the capacity of the 2BH7210/2BH7220 frames. Its 5.0 kW (50 Hz) or 6.2 kW (60 Hz) motor and integrated VFD suit central systems; smaller siblings are adequate for lower flow or pressure duties.

What are the requirements for the mains supply and protection of the integrated frequency converter?

The VFD requires a 3-phase supply within 400 V -15% to 480 V +10% (min. 380 V), with 10 A fuse protection. Rated mains current is 10 A. Ensure the supply can deliver the VFD’s inrush without excessive voltage drop.

What environmental and duty-cycle limits apply to the 2BH7520 installation?

The motor and VFD are IP55 and air-cooled. Install in a well-ventilated area with unobstructed cooling-air flow; ambient temperature limits are not stated in the supplied data sheet. Continuous duty at rated power is permissible, but VFD heat sink must remain clear.

What maintenance items and accessories are not included in the base delivery of the 2BH7520?

The base delivery includes the blower and integrated VFD but not the wall-mount adaptor 2FX16190ER00, line reactor, or process filters/silencers. Regular cleaning of cooling paths is required; no spare-parts kit is listed in the data sheet.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7520 side channel blower (EN)