Elmo Rietschle 2BH753
Elmo Rietschle 2BH753 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 900 mbar, Motor power 5.3 kW, Noise level 69 dB.
The 2BH753 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH7 series, driven by an IE3 three-phase motor rated 17.1 kW at 50 Hz and 19.6 kW at 60 Hz. It delivers a maximum differential pressure of 950 mbar in pressure mode and -680 mbar in vacuum mode at 50 Hz, distinguishing it from smaller siblings such as the 2BH721 and 2BH722 by its higher power and pressure capability. It is intended for continuous industrial vacuum or pressure generation in systems requiring oil-free, contact-free gas handling.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH753 Current | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | 950 mbar (50 Hz) 60 Hz: 900 mbar |
| Motor power | 4.6 kW (50 Hz) 60 Hz: 5.3 kW |
| Noise level | 69 dB(A) (50 Hz) 60 Hz: 72 dB(A) |
| Max differential pressure vacuum mfr | -680 mbar (50 Hz) |
| Max differential pressure vacuum mfr | -690 mbar (60 Hz) |
| Max. differential pressure (vacuum) mfr | -680 mbar (50 Hz) |
| Max. differential pressure (vacuum) mfr | -690 mbar (60 Hz) |
| Weight | 72 kg |
| Current | 17.1 A (50 Hz, 190-210 V D) 60 Hz, 190-210 V UU / 380-420 V U: 19.6 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 D V (50 Hz) 60 Hz: 190-210 UU / 380-420 U V |
| Rated voltage mfr | 500 V (50 Hz) |
| Rated voltage mfr | 575 V (60 Hz) |
| Rated current mfr | 6.9 A (50 Hz) |
| Rated current mfr | 6.8 A (60 Hz) |
| Rated power mfr | 5.3 kW (60 Hz) |
| Efficiency class mfr | IE3 |
| Frequency (alt var) mfr | 60 Hz |
| Inlet connection | G 2 1/2 |
| Outlet connection | G 2 1/2 |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 69 dB(A) (50 Hz) |
| Sound pressure level mfr | 72 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH753 is a single-stage side-channel blower with an IE3 premium-efficiency three-phase motor, IP55 protection, and insulation class F. It weighs 72 kg.
- Within the G-BH7 series, the 2BH753 sits above the 2BH721, 2BH7210, 2BH722, and 2BH7220 in terms of motor power and achievable differential pressure. The 2BH753 is the higher-capacity choice when the smaller siblings cannot meet the required pressure or flow.
- The motor is wound for dual frequency: 380–420 V at 50 Hz and 190–210 V at 60 Hz, with rated currents of 4.6 A and 5.3 A respectively.
Performance behaviour
- Maximum differential pressure is 950 mbar in pressure mode at 50 Hz (900 mbar at 60 Hz) and -680 mbar in vacuum mode at 50 Hz (-690 mbar at 60 Hz).
- Sound pressure level is 69 dB(A) at 50 Hz and 72 dB(A) at 60 Hz, measured under standard conditions.
- No digitized curve points are available in the supplied facts; performance curves must be obtained from the manufacturer's selection software or the full data sheet.
Installation and operation
- The blower is designed for direct coupling to the motor shaft; no belt drive is used. The IP55 motor allows installation in dusty or damp environments, but the motor cooling air must remain unobstructed.
- Electrical connection must match the site voltage and frequency; the dual-voltage design requires correct terminal linking for the intended supply. The IE3 motor may draw a high starting current, so the upstream protection and contactor must be sized accordingly.
- The data sheet references UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate E225239), indicating compliance with North American standards for electrical equipment.
Integration & Operating Notes
The 2BH753 motor is wound for 380–420 V at 50 Hz and 190–210 V at 60 Hz. Incorrect terminal linking will cause excessive current or reduced torque, leading to motor overheating or failure. Verify the supply voltage and frequency before connection and follow the wiring diagram in the terminal box.
Operating above the maximum differential pressure of 950 mbar (50 Hz) or 900 mbar (60 Hz) in pressure mode, or below -680 mbar (50 Hz) or -690 mbar (60 Hz) in vacuum mode, will overload the motor and may cause mechanical damage. Install a pressure relief valve or vacuum breaker if the system can generate higher differentials.
The IP55 motor relies on external cooling air. Mount the blower so that the fan cover and cooling fins are not blocked. In enclosed cabinets, provide adequate ventilation or ducting to prevent ambient temperature rise above the motor's rated conditions.
Side-channel blowers are sensitive to contamination. Inspect the impeller and inlet screen at regular intervals (e.g., every 500 operating hours) and clean or replace the filter element if fitted. Dust buildup reduces performance and can cause imbalance.
Selection & Integration Q&A
Choose the 2BH753 when your process requires differential pressures up to 950 mbar (pressure) or -680 mbar (vacuum) at 50 Hz, which the smaller siblings cannot achieve. The 2BH753 also provides higher flow due to its 17.1 kW motor. Select a smaller model only if the required pressure and flow are within their lower limits, as the 2BH753 has higher power consumption and weight (72 kg).
The motor must be connected to a three-phase supply matching the nameplate voltage and frequency (380–420 V at 50 Hz or 190–210 V at 60 Hz). Use motor protection with a setting corresponding to the rated current (4.6 A at 50 Hz, 5.3 A at 60 Hz). The IE3 motor may have a high starting current; select contactors and fuses accordingly. Ensure the supply is capable of delivering the starting current without excessive voltage drop.
The 2BH753 is rated IP55 and insulation class F, allowing operation in dusty and damp environments. However, the ambient temperature must not exceed the motor's rated ambient (typically 40°C) unless derated. Mount the unit on a level, vibration-free surface and ensure free air flow around the motor. Avoid recirculation of hot exhaust air.
The base delivery includes the blower and motor only. Accessories such as inlet filters, silencers, pressure relief valves, flexible connectors, and mounting feet are not included and must be ordered separately. Maintenance items include replacement filter elements (if used) and periodic cleaning of the impeller. No spare parts are supplied; refer to the spare parts list for ordering.