Elmo Rietschle 2BH753
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH753

Elmo Rietschle 2BH753 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 900 mbar, Motor power 5.3 kW, Noise level 69 dB.

The 2BH753 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH7 series, driven by an IE3 three-phase motor rated 17.1 kW at 50 Hz and 19.6 kW at 60 Hz. It delivers a maximum differential pressure of 950 mbar in pressure mode and -680 mbar in vacuum mode at 50 Hz, distinguishing it from smaller siblings such as the 2BH721 and 2BH722 by its higher power and pressure capability. It is intended for continuous industrial vacuum or pressure generation in systems requiring oil-free, contact-free gas handling.

Max. differential pressure
900 mbar
Motor power
5.3 kW
Noise level
69 dB
Weight
72 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH753 Current 5.3699507217.1190–210
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 950 mbar (50 Hz)
60 Hz: 900 mbar
Motor power 4.6 kW (50 Hz)
60 Hz: 5.3 kW
Noise level 69 dB(A) (50 Hz)
60 Hz: 72 dB(A)
Max differential pressure vacuum mfr -680 mbar (50 Hz)
Max differential pressure vacuum mfr -690 mbar (60 Hz)
Max. differential pressure (vacuum) mfr -680 mbar (50 Hz)
Max. differential pressure (vacuum) mfr -690 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 72 kg
Electrical, Power & Drive Specifications
Current 17.1 A (50 Hz, 190-210 V D)
60 Hz, 190-210 V UU / 380-420 V U: 19.6 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 D V (50 Hz)
60 Hz: 190-210 UU / 380-420 U V
Rated voltage mfr 500 V (50 Hz)
Rated voltage mfr 575 V (60 Hz)
Rated current mfr 6.9 A (50 Hz)
Rated current mfr 6.8 A (60 Hz)
Rated power mfr 5.3 kW (60 Hz)
Efficiency class mfr IE3
Frequency (alt var) mfr 60 Hz
Interfaces, Connections & Control
Inlet connection G 2 1/2
Outlet connection G 2 1/2
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 69 dB(A) (50 Hz)
Sound pressure level mfr 72 dB(A) (60 Hz)

Description

Construction and series positioning

Performance behaviour

Installation and operation

Integration & Operating Notes

Electrical
Motor terminal links must match supply voltage and frequency

The 2BH753 motor is wound for 380–420 V at 50 Hz and 190–210 V at 60 Hz. Incorrect terminal linking will cause excessive current or reduced torque, leading to motor overheating or failure. Verify the supply voltage and frequency before connection and follow the wiring diagram in the terminal box.

Technical Data Sheet — 2BH753 IE3 vacuum pump (EN), Electrical Data
Process Limits
Differential pressure must not exceed 950 mbar in pressure mode

Operating above the maximum differential pressure of 950 mbar (50 Hz) or 900 mbar (60 Hz) in pressure mode, or below -680 mbar (50 Hz) or -690 mbar (60 Hz) in vacuum mode, will overload the motor and may cause mechanical damage. Install a pressure relief valve or vacuum breaker if the system can generate higher differentials.

Technical Data Sheet — 2BH753 IE3 vacuum pump (EN), Performance Data
Mounting
Ensure unobstructed cooling air flow around the motor

The IP55 motor relies on external cooling air. Mount the blower so that the fan cover and cooling fins are not blocked. In enclosed cabinets, provide adequate ventilation or ducting to prevent ambient temperature rise above the motor's rated conditions.

Technical Data Sheet — 2BH753 IE3 vacuum pump (EN), Installation Notes
Maintenance
Inspect and clean the impeller and inlet filter periodically

Side-channel blowers are sensitive to contamination. Inspect the impeller and inlet screen at regular intervals (e.g., every 500 operating hours) and clean or replace the filter element if fitted. Dust buildup reduces performance and can cause imbalance.

Technical Data Sheet — 2BH753 IE3 vacuum pump (EN), Maintenance

Selection & Integration Q&A

When should I choose the 2BH753 over the smaller 2BH721 or 2BH722 models in the G-BH7 series?

Choose the 2BH753 when your process requires differential pressures up to 950 mbar (pressure) or -680 mbar (vacuum) at 50 Hz, which the smaller siblings cannot achieve. The 2BH753 also provides higher flow due to its 17.1 kW motor. Select a smaller model only if the required pressure and flow are within their lower limits, as the 2BH753 has higher power consumption and weight (72 kg).

What are the requirements for the electrical supply and protection when integrating the 2BH753?

The motor must be connected to a three-phase supply matching the nameplate voltage and frequency (380–420 V at 50 Hz or 190–210 V at 60 Hz). Use motor protection with a setting corresponding to the rated current (4.6 A at 50 Hz, 5.3 A at 60 Hz). The IE3 motor may have a high starting current; select contactors and fuses accordingly. Ensure the supply is capable of delivering the starting current without excessive voltage drop.

What are the mounting and ambient temperature limits for the 2BH753?

The 2BH753 is rated IP55 and insulation class F, allowing operation in dusty and damp environments. However, the ambient temperature must not exceed the motor's rated ambient (typically 40°C) unless derated. Mount the unit on a level, vibration-free surface and ensure free air flow around the motor. Avoid recirculation of hot exhaust air.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower and motor only. Accessories such as inlet filters, silencers, pressure relief valves, flexible connectors, and mounting feet are not included and must be ordered separately. Maintenance items include replacement filter elements (if used) and periodic cleaning of the impeller. No spare parts are supplied; refer to the spare parts list for ordering.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH753 IE3 vacuum pump (EN)
Datasheet ·724,2 КБ ·2 pp.
View PDF