Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — G-BH7 2BH7210 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH7 210: side channel blower with integrated frequency converter (VFD), type 2BH7210. Covers 50 Hz and 60 Hz operation, 400 V and 380 V rated motor voltage, U and D connection variants, and VFD types A–K (2FC4xxx-1□□00).

Technical Data

Parameter Value Condition
Rated motor voltage 400 V p.2 ↗ 2BH7210, 50 Hz, U connection
Rated motor current 5,1 A p.2 ↗ 2BH7210, 50 Hz, U connection
Rated motor power 2,6 kW p.2 ↗ 2BH7210, 50 Hz, U connection
Max. differential pressure, vacuum -440 mbar p.2 ↗ 2BH7210, 50 Hz, U connection
Max. differential pressure, pressure 560 mbar p.2 ↗ 2BH7210, 50 Hz, U connection
Sound pressure level 73 dB(A) p.2 ↗ 2BH7210, 50 Hz, U connection
Weight 32 kg p.2 ↗ 2BH7210, 50 Hz, U connection
Rated motor voltage 380 V p.2 ↗ 2BH7210, 87 Hz, U connection
Rated motor current 4,8 A p.2 ↗ 2BH7210, 87 Hz, U connection
Rated motor power 2,3 kW p.2 ↗ 2BH7210, 87 Hz, U connection
Max. differential pressure, vacuum -420 mbar p.2 ↗ 2BH7210, 87 Hz, U connection
Max. differential pressure, pressure 600 mbar p.2 ↗ 2BH7210, 87 Hz, U connection
Sound pressure level 73 dB(A) p.2 ↗ 2BH7210, 87 Hz, U connection
Weight 32 kg p.2 ↗ 2BH7210, 87 Hz, U connection
Rated motor voltage 400 V p.2 ↗ 2BH7210, 87 Hz, D connection
Rated motor current 3,45 A p.2 ↗ 2BH7210, 87 Hz, D connection
Rated motor power 1,6 kW p.2 ↗ 2BH7210, 87 Hz, D connection
Max. differential pressure, vacuum -420 mbar p.2 ↗ 2BH7210, 87 Hz, D connection
Max. differential pressure, pressure 420 mbar p.2 ↗ 2BH7210, 87 Hz, D connection
Sound pressure level 73 dB(A) p.2 ↗ 2BH7210, 87 Hz, D connection
Weight 29 kg p.2 ↗ 2BH7210, 87 Hz, D connection
Rated motor voltage 400 V p.2 ↗ 2BH7210, 87 Hz, D connection, variant B
Rated motor current 4,6 A p.2 ↗ 2BH7210, 87 Hz, D connection, variant B
Rated motor power 2,3 kW p.2 ↗ 2BH7210, 87 Hz, D connection, variant B
Max. differential pressure, pressure 600 mbar p.2 ↗ 2BH7210, 87 Hz, D connection, variant B

Operating Limits

  • Max. ambient / suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Sound pressure level tolerance: ±3 dB(A) p.2 ↗
  • Integrated VFD mains voltage range: 3~ 400 V -15% … 480 V +10% p.2 ↗
  • Integrated VFD mains frequency: 50/60 Hz ±6% p.2 ↗
  • Minimum frequency converter mains voltage: 380 V p.1 ↗

Type Code Decoder

Position Token Meaning
1-6 p.2 ↗ 2BH7210 Type designation: side channel blower 2BH7 series, size 210
field 1 p.2 ↗ 0A / 0K Motor / connection variant (U or D connection, VFD variant)
field 2 p.2 ↗ 3 / 4 Voltage / frequency variant (e.g. 400 V 50 Hz, 380 V 87 Hz, 400 V 87 Hz)
field 3 p.2 ↗ 4 / 6 Power / performance variant
field 4 p.2 ↗ 1 Design / revision index
VFD type field 1 p.2 ↗ A–K VFD size / power class (2FC4xxx-1□□00)
VFD type field 2 p.2 ↗ □□ Mains voltage / frequency variant placeholder

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7210-0A341-1 p.2 ↗ 2BH7210-0A341-1 50 Hz, 400 V U connection VFD type B
2BH7210-0A346-1 p.2 ↗ 2BH7210-0A346-1 87 Hz, 380 V U connection VFD type B
2BH7210-0AK36-1 p.2 ↗ 2BH7210-0AK36-1 60 Hz, 400 V U connection PTC recommended; VFD type B
2BH7210-0AK46-1 p.2 ↗ 2BH7210-0AK46-1 87 Hz, 400 V D connection PTC recommended; VFD type B