Technical Data Sheet — G-BH7 2BH7220 side channel blower (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet 2BH7 220: side channel blower with integrated frequency converter (VFD), type 2BH7 220. Covers 50 Hz and 60 Hz operation, 3~ 400 V and 380 V motor variants, and integrated VFD types A–K (2FC4...).

Technical Data

Parameter Value Condition
Rated motor voltage 400 V p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Rated motor current 6,5 A p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Rated motor power 3,5 kW p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Max. differential pressure (vacuum) -660 mbar p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Max. differential pressure (pressure) 660 mbar p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Sound pressure level 77 dB(A) p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Weight 41 kg p.2 ↗ 2BH7 220, 50 Hz, 100 Hz operation
Rated motor voltage 380 V p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Rated motor current 6,1 A p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Rated motor power 2,90 kW p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Max. differential pressure (vacuum) -660 mbar p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Max. differential pressure (pressure) 800 mbar p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Sound pressure level 77 dB(A) p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Weight 39 kg p.2 ↗ 2BH7 220, 50 Hz, 87 Hz operation
Max. differential pressure (vacuum) -370 mbar p.2 ↗ 2BH7 220, 60 Hz, 50 Hz operation
Max. differential pressure (pressure) 490 mbar p.2 ↗ 2BH7 220, 60 Hz, 50 Hz operation
Sound pressure level 58 dB(A) p.2 ↗ 2BH7 220, 60 Hz, 50 Hz operation
Weight 30 kg p.2 ↗ 2BH7 220, 60 Hz, 50 Hz operation
Max. differential pressure (vacuum) -500 mbar p.2 ↗ 2BH7 220, 60 Hz, 60 Hz operation
Max. differential pressure (pressure) 770 mbar p.2 ↗ 2BH7 220, 60 Hz, 60 Hz operation
Sound pressure level 62 dB(A) p.2 ↗ 2BH7 220, 60 Hz, 60 Hz operation
Weight 36 kg p.2 ↗ 2BH7 220, 60 Hz, 60 Hz operation
Protection class IP55 p.2 ↗ Motor and integrated VFD
Insulation material class F p.2 ↗ Motor

Operating Limits

  • Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
  • Performance curve tolerance: ±10 % p.1 ↗
  • Minimum VFD pulse frequency: 4 kHz p.1 ↗
  • Minimum mains voltage for frequency converter: 380 V p.1 ↗
  • Protection class: IP55 p.2 ↗

Type Code Decoder

Position Token Meaning
1-7 p.2 ↗ 2BH7220 Type designation: side channel blower 2BH7, size 220
8-13 p.2 ↗ 0A351- / 0A356- / 0AK36- / 0AK56- Motor/voltage/frequency variant code (e.g. 0A351 = 400 V 100 Hz, 0A356 = 380 V 87 Hz, 0AK36 = 60 Hz 50 Hz, 0AK56 = 60 Hz 60 Hz)
Z field p.2 ↗ A11 PTC thermistor motor overload protection option (ordering example: 2BH7220-□□□□□-□-Z Z=A11)
VFD type field p.2 ↗ A–K Integrated frequency converter type (2FC4...), selected by letter A to K

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7220-0A351-1 p.2 ↗ 2BH7220-0A351-1 400 V, 100 Hz, 50 Hz mains VFD type C
2BH7220-0A356-1 p.2 ↗ 2BH7220-0A356-1 380 V, 87 Hz, 50 Hz mains VFD type C
2BH7220-0AK36-1 p.2 ↗ 2BH7220-0AK36-1 60 Hz mains, 50 Hz operation VFD type D
2BH7220-0AK56-1 p.2 ↗ 2BH7220-0AK56-1 60 Hz mains, 60 Hz operation VFD type D