Induztr
Engineering Digest Document Viewer Related Models

Technical Data Sheet — 2BH7630 vacuum pump (EN)

Technical Reference Summary

Covered Models & Document Scope

Data sheet for side channel blower type 2BH7 630-0A (G-BH 7 N series) with IE3 motors; covers 50 Hz and 60 Hz variants, single- and two-stage (No. 1 / No. 2), various voltage codes (K, Q, VD/VY connections), IE3 and NP efficiency variants.

Technical Data

Parameter Value Condition
Rated frequency 50 Hz p.2 ↗ 2BH7630-0AK71-2, No. 1
Voltage 190-210 D V p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Current 23,5 D A p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Power 6,3 kW p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Max. differential pressure vacuum -680 mbar p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Max. differential pressure pressure 950 mbar p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Sound pressure level 64 dB(A) p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Efficiency class IE3 p.2 ↗ 2BH7630-0AK71-2, 50 Hz
Weight 89 kg p.2 ↗ 2BH7630-0AK71-2
Rated frequency 60 Hz p.2 ↗ 2BH7630-0AK71-2, No. 1
Voltage 190-210 / 380-420 V p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Current 27,6 / 13,8 A p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Power 7,3 kW p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Max. differential pressure vacuum -640 mbar p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Max. differential pressure pressure 840 mbar p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Sound pressure level 66 dB(A) p.2 ↗ 2BH7630-0AK71-2, 60 Hz
Power 8,6 kW p.2 ↗ 2BH7630-0AK61-2, No. 2, 50 Hz
Max. differential pressure vacuum -680 mbar p.2 ↗ 2BH7630-0AK61-2, No. 2, 50 Hz
Max. differential pressure pressure 1050 mbar p.2 ↗ 2BH7630-0AK61-2, No. 2, 50 Hz
Weight 101 kg p.2 ↗ 2BH7630-0AK61-2, No. 2
Protection category IP55 p.1 ↗ all variants
Insulation class F p.1 ↗ all variants
Ambient / suction temperature for stated pressure differences up to 25 °C p.1 ↗ all variants
Performance curve tolerance ± 10 % p.1 ↗ air at 15 °C, 1013 mbar

Operating Limits

  • Max. ambient / suction temperature for stated total pressure differences: 25 °C p.1 ↗
  • Protection category: IP55 p.1 ↗
  • Insulation class: F p.1 ↗
  • Performance curve tolerance: ± 10 % p.1 ↗

Type Code Decoder

Position Token Meaning
1-4 p.2 ↗ 2BH7 Series / type: side channel blower G-BH 7
5-7 p.2 ↗ 630 Size 630
8-9 p.2 ↗ 0A Design variant 0A
field 1 (after 0A) p.2 ↗ K / Q Voltage / motor variant code (K = 190-210 V and 200 V variants; Q = 220-240/380-420 V, 440-480 V, 500 V, 575 V, 400/690 V, 475-525/550-600 V variants)
field 2 (after voltage code) p.2 ↗ 7 / 6 / 3 / 5 Voltage connection sub-variant (e.g. K7 = 220-240 VΔ/380-420 VY, 440-480 VY; K6 = 400 VΔ/690 VY, 460 VΔ; Q3 = 475-525 VY, 550-600 VY; Q5 = 475-525 VΔ, 550-600 VΔ)
field 3 (after hyphen) p.2 ↗ 1 / 2 Number of stages: 1 = single-stage, 2 = two-stage
suffix p.2 ↗ -2 Motor variant / generation suffix

Ordering Data

Ordering Code Part No. Variant / Code Applies To Note
2BH7630-0AK71-2 p.2 ↗ 2BH7630-0AK71-2 K71 No. 1, 50 Hz 190-210 VΔ; 60 Hz 190-210/380-420 V IE3, 89 kg
2BH7630-0AK61-2 p.2 ↗ 2BH7630-0AK61-2 K61 No. 2, 50 Hz 190-210 VΔ; 60 Hz 190-210/380-420 V IE3, 101 kg
2BH7630-0AK76-2 p.2 ↗ 2BH7630-0AK76-2 K76 No. 1, 50 Hz 220-240 VΔ/380-420 VY; 60 Hz 220-240/440-480 V IE3, 89 kg
2BH7630-0AK66-2 p.2 ↗ 2BH7630-0AK66-2 K66 No. 2, 50 Hz 220-240 VΔ/380-420 VY; 60 Hz 220-240/440-480 V IE3, 101 kg
2BH7630-0AQ73-2 p.2 ↗ 2BH7630-0AQ73-2 Q73 No. 1, 50 Hz 500 V; 60 Hz 575 V IE3, 89 kg
2BH7630-0AQ63-2 p.2 ↗ 2BH7630-0AQ63-2 Q63 No. 2, 50 Hz 500 V; 60 Hz 575 V IE3, 101 kg
2BH7630-0AQ77-2 p.2 ↗ 2BH7630-0AQ77-2 Q77 No. 1, 50 Hz 400 VΔ/690 VY; 60 Hz 440-480 VΔ IE3, 89 kg
2BH7630-0AQ67-2 p.2 ↗ 2BH7630-0AQ67-2 Q67 No. 2, 50 Hz 380-420 VΔ/660-725 VY; 60 Hz 440-480 VΔ IE3, 101 kg
2BH7630-0AQ76-2 p.2 ↗ 2BH7630-0AQ76-2 Q76 No. 1, 50 Hz 220-240 VΔ/380-420 VY; 60 Hz 440-480 V IE3, 89 kg
2BH7630-0AQ66-2 p.2 ↗ 2BH7630-0AQ66-2 Q66 No. 2, 50 Hz 220-240 VΔ/380-420 VY; 60 Hz 440-480 V IE3, 101 kg