Elmo Rietschle 2BH7210
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7210

Elmo Rietschle 2BH7210 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 0.55 kW, Noise level 59 dB.

The 2BH7210 is a side-channel (regenerative) blower in the G-BH7 series, configured as a single-stage, directly driven unit with a three-phase or single-phase motor. It delivers up to 310 mbar positive pressure and -260 mbar vacuum at 50 Hz, distinguishing it from smaller siblings by its higher pressure capability within the same frame. It is used for contactless conveying, vacuum holding, and aeration in industrial systems where oil-free, pulsation-free air is required.

Max. differential pressure
-230 mbar
Motor power
0.55 kW
Noise level
59 dB
Weight
16 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7210 Current 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH721 159-300214.2190–210
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400
2BH7630 1680-50012129400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -230 mbar (50 Hz)
60 Hz: -270 mbar
Motor power 0.55 kW (50 Hz)
60 Hz: 0.63 kW
Noise level 59 dB (50 Hz)
60 Hz: 63 dB
Max. differential pressure vacuum mfr -260 mbar (60 Hz)
Order No. mfr 2BH7210-0AV75-7 (50 Hz)
Order No. mfr 2BH7210-0AV75-7 (60 Hz)
Max. differential pressure (alt 50 Hz) mfr 290 mbar (50 Hz)
Max. differential pressure (alt 60 Hz) mfr 320 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 16 kg (50 Hz)
60 Hz: 16 kg
Electrical, Power & Drive Specifications
Current 2.8 △ / 1.6 Y A (50 Hz)
60 Hz: 3.0 △ / 1.7 Y A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 200-240 △ / 345-415 Y V (50 Hz)
60 Hz: 220-275 △ / 380-480 Y V
Rated voltage mfr 115 V (50 Hz)
Rated current mfr 14.2 A (50 Hz)
Rated current mfr 1.09 A (60 Hz)
Rated power mfr 0.63 kW (50 Hz)
Motor frequency tolerance mfr +/- 2 %
Three phase voltage tolerance fixed voltage mfr +/-10 %
Three phase voltage tolerance voltage range mfr +/-5 %
Single phase voltage tolerance mfr +/-5 %
Voltage range mfr 350-450 D / 610-725 Y V (50 Hz)
Voltage range mfr 400-500 D / 690-725 Y V (60 Hz)
Fixed voltage mfr 400 D / 690 Y V (50 Hz)
Fixed voltage mfr 460 D V (60 Hz)
Fixed voltage mfr 400 Δ V (87 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 59 dB(A) (50 Hz)
Sound pressure level mfr 63 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection, and operation

Integration & Operating Notes

Electrical
Motor voltage tolerance is tight for voltage-range supplies

When the motor is connected to a voltage range (e.g., 200-240 Δ / 345-415 Y at 50 Hz or 220-275 Δ / 380-480 Y at 60 Hz), the supply voltage must stay within ±5% of the nominal range. Exceeding this can cause overheating or reduced torque, leading to premature failure. For fixed-voltage connections, tolerance is ±10%. Verify the actual supply voltage under load before commissioning.

Technical Data Sheet — G-BH7 2BH7210, Electrical Data
Mounting
Install with adequate clearance for cooling air

The motor relies on fan cooling; obstructing airflow around the motor housing can cause overheating. Maintain at least 100 mm clearance on all sides of the motor fan cover. Do not install in enclosed cabinets without forced ventilation. Ambient temperature should not exceed 40°C for continuous duty.

Technical Data Sheet — G-BH7 2BH7210, Installation
Control & I/O
Use a motor protection switch to prevent overload

The blower should be protected by a thermal overload relay or motor protection switch set to the rated current for the specific voltage variant: 14.2 A for the 115 V single-phase variant at 50 Hz, or 1.09 A for the 200-240 Δ / 345-415 Y three-phase variant at 60 Hz. Without proper protection, a blocked impeller or excessive pressure can overheat the motor and void warranty. Integrate the protection into the control circuit to trip the contactor.

Technical Data Sheet — G-BH7 2BH7210, Electrical Connection
Maintenance
Inspect impeller and bearings every 2000 operating hours

Side-channel blowers are sensitive to debris; accumulated dust on the impeller reduces performance and causes imbalance. Every 2000 hours, remove the inlet filter (if fitted) and inspect the impeller through the inlet port. Clean with compressed air. Motor bearings are sealed and require no lubrication, but should be checked for noise and replaced after 20,000 hours.

Technical Data Sheet — G-BH7 2BH7210, Maintenance

Selection & Integration Q&A

When should I choose the 2BH7210 over the 2BH7220 or 2BH731?

Choose the 2BH7210 when you need up to 310 mbar pressure or -270 mbar vacuum at moderate flow. The 2BH7220 offers higher flow at similar pressure, while the 2BH731 provides higher pressure for demanding applications. Select based on required pressure and flow; the 2BH7210 is the mid-range option.

What are the requirements for the power supply and motor protection when integrating this blower?

The 2BH7210 requires a three-phase supply (e.g., 200-240 Δ / 345-415 Y at 50 Hz or 220-275 Δ / 380-480 Y at 60 Hz) or single-phase 115 V at 50 Hz, with voltage tolerance of ±5% for range supplies. Use a motor protection switch set to 14.2 A for the 115 V single-phase variant at 50 Hz, or 1.09 A for the 200-240 Δ / 345-415 Y three-phase variant at 60 Hz. Ensure the cable glands maintain IP55 sealing.

Can the 2BH7210 be installed outdoors or in a dusty environment?

The motor is IP55, so it is protected against dust and water jets, but the terminal box must be sealed. For outdoor installation, provide a rain cover and avoid direct sunlight. Ambient temperature must not exceed 40°C. In dusty environments, clean the motor fan cover regularly to prevent overheating.

What maintenance parts and accessories are recommended for the 2BH7210, and are they included?

The base delivery includes the blower only. Recommended accessories: inlet filter (to protect impeller), flexible connectors (to reduce vibration), and a motor protection switch. Spare parts: impeller, bearings (after 20,000 hours), and gaskets. These are not included and must be ordered separately.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7210 vacuum pump (EN)
Datasheet ·327,0 КБ ·2 pp.
View PDF