Elmo Rietschle 2BH7210
Elmo Rietschle 2BH7210 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 0.55 kW, Noise level 59 dB.
The 2BH7210 is a side-channel (regenerative) blower in the G-BH7 series, configured as a single-stage, directly driven unit with a three-phase or single-phase motor. It delivers up to 310 mbar positive pressure and -260 mbar vacuum at 50 Hz, distinguishing it from smaller siblings by its higher pressure capability within the same frame. It is used for contactless conveying, vacuum holding, and aeration in industrial systems where oil-free, pulsation-free air is required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7210 Current | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -230 mbar (50 Hz) 60 Hz: -270 mbar |
| Motor power | 0.55 kW (50 Hz) 60 Hz: 0.63 kW |
| Noise level | 59 dB (50 Hz) 60 Hz: 63 dB |
| Max. differential pressure vacuum mfr | -260 mbar (60 Hz) |
| Order No. mfr | 2BH7210-0AV75-7 (50 Hz) |
| Order No. mfr | 2BH7210-0AV75-7 (60 Hz) |
| Max. differential pressure (alt 50 Hz) mfr | 290 mbar (50 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 320 mbar (60 Hz) |
| Weight | 16 kg (50 Hz) 60 Hz: 16 kg |
| Current | 2.8 △ / 1.6 Y A (50 Hz) 60 Hz: 3.0 △ / 1.7 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 200-240 △ / 345-415 Y V (50 Hz) 60 Hz: 220-275 △ / 380-480 Y V |
| Rated voltage mfr | 115 V (50 Hz) |
| Rated current mfr | 14.2 A (50 Hz) |
| Rated current mfr | 1.09 A (60 Hz) |
| Rated power mfr | 0.63 kW (50 Hz) |
| Motor frequency tolerance mfr | +/- 2 % |
| Three phase voltage tolerance fixed voltage mfr | +/-10 % |
| Three phase voltage tolerance voltage range mfr | +/-5 % |
| Single phase voltage tolerance mfr | +/-5 % |
| Voltage range mfr | 350-450 D / 610-725 Y V (50 Hz) |
| Voltage range mfr | 400-500 D / 690-725 Y V (60 Hz) |
| Fixed voltage mfr | 400 D / 690 Y V (50 Hz) |
| Fixed voltage mfr | 460 D V (60 Hz) |
| Fixed voltage mfr | 400 Δ V (87 Hz) |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 59 dB(A) (50 Hz) |
| Sound pressure level mfr | 63 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH7210 is a single-stage side-channel blower with an impeller directly mounted on the motor shaft, eliminating belts or couplings. The motor is flanged to the blower housing, forming a compact, vibration-resistant unit.
- Within the G-BH7 series, the 2BH7210 sits above the 2BH721 and 2BH722 in pressure capability, offering 290 mbar (50 Hz) versus lower values for smaller models. The 2BH7220 and 2BH731 are larger or higher-flow variants; the 2BH7210 balances pressure and flow for medium-duty applications.
- The blower is available with various motor voltages (e.g., 200-240 Δ / 345-415 Y at 50 Hz, 220-275 Δ / 380-480 Y at 60 Hz, and 115 V at 50 Hz) to suit different supply systems. The protection category IP55 and insulation class F allow operation in dusty and humid environments.
Behavior under load and in different media
- The maximum differential pressure is 290 mbar in pressure mode and -230 mbar in vacuum mode at 50 Hz; at 60 Hz these values increase to 310 mbar and -270 mbar due to higher speed. The blower can operate continuously at these limits, but higher pressures require larger models.
- The sound pressure level is 59 dB(A) at 50 Hz and 63 dB(A) at 60 Hz, measured at 1 m distance in free field. This is typical for side-channel blowers and may require acoustic enclosure in noise-sensitive areas.
- The blower is oil-free and handles air and non-aggressive gases. The compression is achieved by kinetic energy transfer through the side channel, resulting in a pulsation-free output. The motor is rated for continuous duty (S1) and can be started directly or via a contactor.
Installation, connection, and operation
- The blower can be mounted in any orientation, but the motor must be protected from moisture and dust. The IP55 rating applies to the motor, not the terminal box, which must be properly sealed. The blower should be installed on a flat, vibration-free surface using the mounting feet.
- Electrical connection is made to the terminal box, which accommodates cable glands for power and control wiring. The motor is designed for direct-on-line starting; for star-delta starting, the motor windings must be configured accordingly (Δ/Y). The voltage tolerance is ±10% for fixed voltage and ±5% for voltage range, ensuring stable operation.
- The blower is cooled by the conveyed air and motor fan. Ensure sufficient clearance around the unit for heat dissipation. The maximum ambient temperature is typically 40°C; higher temperatures reduce motor life. Regular maintenance includes checking the impeller for debris and verifying the motor bearings after extended operation.
Integration & Operating Notes
When the motor is connected to a voltage range (e.g., 200-240 Δ / 345-415 Y at 50 Hz or 220-275 Δ / 380-480 Y at 60 Hz), the supply voltage must stay within ±5% of the nominal range. Exceeding this can cause overheating or reduced torque, leading to premature failure. For fixed-voltage connections, tolerance is ±10%. Verify the actual supply voltage under load before commissioning.
The motor relies on fan cooling; obstructing airflow around the motor housing can cause overheating. Maintain at least 100 mm clearance on all sides of the motor fan cover. Do not install in enclosed cabinets without forced ventilation. Ambient temperature should not exceed 40°C for continuous duty.
The blower should be protected by a thermal overload relay or motor protection switch set to the rated current for the specific voltage variant: 14.2 A for the 115 V single-phase variant at 50 Hz, or 1.09 A for the 200-240 Δ / 345-415 Y three-phase variant at 60 Hz. Without proper protection, a blocked impeller or excessive pressure can overheat the motor and void warranty. Integrate the protection into the control circuit to trip the contactor.
Side-channel blowers are sensitive to debris; accumulated dust on the impeller reduces performance and causes imbalance. Every 2000 hours, remove the inlet filter (if fitted) and inspect the impeller through the inlet port. Clean with compressed air. Motor bearings are sealed and require no lubrication, but should be checked for noise and replaced after 20,000 hours.
Selection & Integration Q&A
Choose the 2BH7210 when you need up to 310 mbar pressure or -270 mbar vacuum at moderate flow. The 2BH7220 offers higher flow at similar pressure, while the 2BH731 provides higher pressure for demanding applications. Select based on required pressure and flow; the 2BH7210 is the mid-range option.
The 2BH7210 requires a three-phase supply (e.g., 200-240 Δ / 345-415 Y at 50 Hz or 220-275 Δ / 380-480 Y at 60 Hz) or single-phase 115 V at 50 Hz, with voltage tolerance of ±5% for range supplies. Use a motor protection switch set to 14.2 A for the 115 V single-phase variant at 50 Hz, or 1.09 A for the 200-240 Δ / 345-415 Y three-phase variant at 60 Hz. Ensure the cable glands maintain IP55 sealing.
The motor is IP55, so it is protected against dust and water jets, but the terminal box must be sealed. For outdoor installation, provide a rain cover and avoid direct sunlight. Ambient temperature must not exceed 40°C. In dusty environments, clean the motor fan cover regularly to prevent overheating.
The base delivery includes the blower only. Recommended accessories: inlet filter (to protect impeller), flexible connectors (to reduce vibration), and a motor protection switch. Spare parts: impeller, bearings (after 20,000 hours), and gaskets. These are not included and must be ordered separately.