Elmo Rietschle 2BH7520
Elmo Rietschle 2BH7520 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -520 mbar, Motor power 4.3 kW, Noise level 77 dB.
The 2BH7520 is a side-channel blower with integrated frequency converter, configured for 400 V 50/60 Hz operation and delivering up to -520 mbar vacuum at 50 Hz. As the largest frame in the G-BH7 series, it is distinguished by its 5.0 kW rated power and factory-matched VFD, enabling speed control without external drive engineering. It serves as a central vacuum source in pneumatic conveying, drying, and pick-and-place systems requiring high differential pressure.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7520 Current | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7610 | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -320 mbar (100 Hz, 400 V) 87 Hz, 345 V: -520 mbar |
| Motor power | 5.0 kW (100 Hz, 400 V) 87 Hz, 345 V: 4.3 kW |
| Noise level | 77 dB(A) (100 Hz) 87 Hz: 77 dB(A) |
| Max. differential pressure vacuum mfr | -520 mbar (50 Hz) |
| Order No. mfr | 2BH7520-0A321-1 (50 Hz) |
| Order No. mfr | 2BH7520-0A326-1 (60 Hz) |
| Max. differential pressure vacuum mfr | -490 mbar (60 Hz) |
| Motor connection mfr | delta |
| Max. differential pressure vacuum mfr | -560 mbar |
| Order No. mfr | 2BH7520-0A371-1 |
| Connection mfr | delta |
| Performance curve tolerance mfr | ± 10 % |
| Max. differential pressure (alt 100 Hz, 400 V) mfr | 240 mbar (100 Hz, 400 V) |
| Max. differential pressure (alt 87 Hz, 345 V) mfr | 380 mbar (87 Hz, 345 V) |
| Weight | 57 kg (100 Hz) 87 Hz: 57 kg |
| Weight approx. mfr | 71 kg |
| Current | 9.8 A (100 Hz, 400 V) 87 Hz, 345 V: 8.7 A |
| Frequency | 50/60 Hz (±6%) |
| Voltage | 400 V (-15%) … 480 V (+10%) V 100 Hz: 400 V · 87 Hz: 345 V |
| Rated current mfr | 16.2 A (60 Hz) |
| Rated power mfr | 6.2 kW (60 Hz) |
| Frequency Converter rated mains voltage mfr | 400 V -15% ... 480 V +10% V |
| Frequency Converter rated mains current mfr | 10 A |
| Frequency Converter max. motor current mfr | 5.6 A |
| Frequency Converter typical motor power mfr | 3.0 kW |
| Frequency Converter fuse protection mfr | 10 A |
| Frequency Converter type mfr | 2FC4152-1 □ □00 |
| Frequency Converter weight approx. mfr | 3.3 kg |
| Rated voltage/frequency set point mfr | 345 V (87 Hz) |
| Minimum mains voltage for frequency converter mfr | 380 V |
| Pulse frequency minimum mfr | 4 kHz |
| Rated motor voltage mfr | 400 U V |
| Rated motor current mfr | 16.2 U A |
| Rated motor power mfr | 8.8 kW |
| Frequency converter mains voltage minimum mfr | 380 V |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 69 dB(A) (50 Hz) |
| Sound pressure level mfr | 71 dB(A) (60 Hz) |
| Sound pressure level mfr | 81 dB(A) |
Description
Construction and series positioning
- Side-channel (regenerative) blower with cast housing and directly coupled motor; the 2BH7520 is the highest-capacity model in the G-BH7 series, above the 2BH721/2BH722 frames.
- Integrated frequency converter (type 2FC4152-1□□00) is factory-matched to the motor, eliminating the need for a separate drive cabinet.
- Motor connection is delta; insulation class F, protection class IP55.
Performance and load behavior
- At 50 Hz: rated 5.0 kW, 9.8 A, max vacuum -520 mbar, sound pressure 69 dB(A).
- At 60 Hz: rated 6.2 kW, 16.2 A, max vacuum -490 mbar, sound pressure 71 dB(A).
- VFD operation: rated voltage/frequency set point 345 V / 87 Hz; minimum pulse frequency 4 kHz; VFD rated mains current 10 A, max motor current 5.6 A, typical motor power 3.0 kW.
- No digitized curve points were supplied; performance at intermediate speeds must be obtained from the manufacturer’s selection software.
Installation, connection and control
- The VFD accepts 400 V -15% … 480 V +10% mains; minimum mains voltage 380 V. Fuse protection 10 A.
- Wall-mount adaptor 2FX16190ER00 is available for the VFD when not mounted on the blower.
- The blower is air-cooled; ensure unobstructed cooling-air flow and sufficient clearance around the motor and VFD heat sink.
- Control via the VFD’s digital/analog inputs (refer to VFD manual for terminal assignment); no separate motor starter is required.
Integration & Operating Notes
The frequency converter is rated for 400 V -15% … 480 V +10%, with an absolute minimum of 380 V. Operation below 380 V may cause undervoltage trips or erratic motor control; above 480 V risks overvoltage damage to the DC bus. Verify site voltage under load before commissioning.
The motor is delta-connected and the VFD must be parameterized to the factory set point of 345 V / 87 Hz. Running with default 400 V / 50 Hz settings will over-flux the motor and may trip on overcurrent. Confirm this parameter before enabling the drive.
At 50 Hz the maximum differential pressure is -520 mbar; at 60 Hz it is -490 mbar. Do not assume the higher frequency yields higher vacuum. Size the process for the frequency actually used, and note that VFD operation at 87 Hz set point may further alter the achievable vacuum.
If the VFD is not mounted directly on the blower, use the specified wall-mount adaptor. Ensure the mounting surface can carry the 3.3 kg VFD and that the motor cable length and shielding meet the VFD manufacturer’s EMC requirements.
The blower and VFD are air-cooled. Dust or debris blocking the motor fan cover or VFD heat sink will cause overheating and premature trips. Inspect and clean these areas according to the site’s duty cycle; no specific interval is given in the supplied data sheet.
Selection & Integration Q&A
Choose the 2BH7520 when the process requires up to -520 mbar vacuum at 50 Hz or -490 mbar at 60 Hz, at flow rates beyond the capacity of the 2BH7210/2BH7220 frames. Its 5.0 kW (50 Hz) or 6.2 kW (60 Hz) motor and integrated VFD suit central systems; smaller siblings are adequate for lower flow or pressure duties.
The VFD requires a 3-phase supply within 400 V -15% to 480 V +10% (min. 380 V), with 10 A fuse protection. Rated mains current is 10 A. Ensure the supply can deliver the VFD’s inrush without excessive voltage drop.
The motor and VFD are IP55 and air-cooled. Install in a well-ventilated area with unobstructed cooling-air flow; ambient temperature limits are not stated in the supplied data sheet. Continuous duty at rated power is permissible, but VFD heat sink must remain clear.
The base delivery includes the blower and integrated VFD but not the wall-mount adaptor 2FX16190ER00, line reactor, or process filters/silencers. Regular cleaning of cooling paths is required; no spare-parts kit is listed in the data sheet.