Elmo Rietschle 2BH7610
Elmo Rietschle 2BH7610 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -440 mbar, Motor power 5.8 kW, Noise level 80 dB.
The 2BH7610 is a side-channel blower with an integrated frequency converter (IP55) and wall-mounting configuration, delivering up to 420 mbar differential pressure at 50 Hz and 440 mbar at 60 Hz from a 5.5–5.8 kW motor. It is distinguished within the G-BH7 series by its factory-integrated VFD, enabling speed control without external cabinet space. Primary use is vacuum or pressure generation in pneumatic conveying, drying, and aeration systems where compact, controllable air supply is required.
Elmo Rietschle G-BH7 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Max. differential pressure, mbar | Weight, kg | Current, A | Voltage, V |
|---|---|---|---|---|---|---|
| 2BH7610 Current | 5.8 | 80 | -410 | 55 | 12.7 | 380 |
| 2BH721 | 1 | 59 | -300 | 21 | 4.2 | 190–210 |
| 2BH7210 | 0.63 | 63 | -270 | 16 | 3.0 △ / 1.7 Y | 220-275 △ / 380-480 Y |
| 2BH722 | 1.1 | 58 | 480 | 28 | 4.8 UU / 2.4 U | 190-210 UU / 380-420 U |
| 2BH7220 | 0.81 | 58 | -440 | 24 | 4 | 220-275 / 380-480 Y |
| 2BH731 | 1.1 | 63 | -340 | 24 | 2.8–5.5 | 190-210 / 380-420 |
| 2BH7310 | 0.63 | 58 | 250 | — | 2.8 | 200-240 / 345-415 Y |
| 2BH732 | 1.3 | 64 | 440 | 33 | 3.2 | 190-210 / 380-420 |
| 2BH7320 | 3.5 | 77 | -510 | 48 | 6.5 | — |
| 2BH741 | 1.3 | 63 | — | 26 | 6.3 | 190–210 |
| 2BH7410 | 2.6 | 73 | -230 | 33 | 5.2 | 400 |
| 2BH742 | 1.8 | 64 | 460 | 38 | 3.9–7.8 | 190-210 / 380-420 |
| 2BH7420 | 2.9 | 77 | -270 | 45 | 6.5 | 380 |
| 2BH751 | 1.8 | 68 | -340 | 33 | 7.8 UU | 190-210 UU / 380-420 U |
| 2BH7510 | 6.6 | 78 | 430 | 43 | 12.7 | 400 |
| 2BH752 | 2.5 | 64 | -520 | 50 | 12 | 190-210 / 380-420 |
| 2BH7520 | 4.3 | 77 | -520 | 57 | 8.7 | 400 V (-15%) … 480 V (+1 |
| 2BH753 | 5.3 | 69 | 950 | 72 | 17.1 | 190–210 |
| 2BH7530 | 7.5 | 70 | -610 | 80 | 16.2 | 400 |
| 2BH7620 | 8.8 | 79 | -530 | 77 | 16.2 | 400 |
| 2BH7630 | 16 | 80 | -500 | 121 | 29 | 400 |
Full specifications
| Max. differential pressure | -410 mbar (100 Hz) 87 Hz: -440 mbar |
| Motor power | 6.6 kW (100 Hz) 87 Hz: 5.8 kW |
| Noise level | 80 dB (100 Hz) 87 Hz: 80 dB |
| Max differential pressure vacuum mfr | 420 mbar (50 Hz) |
| Max differential pressure vacuum mfr | 440 mbar (60 Hz) |
| Model code mfr | 2BH7610-0A |
| Order No. mfr | 2BH7610-0A321-2 (100 Hz) |
| Max. differential pressure vacuum mfr | -440 mbar (87 Hz) |
| Order No. mfr | 2BH7610-0A326-2 (87 Hz) |
| Max. differential pressure (alt 100 Hz) mfr | 350 mbar (100 Hz) |
| Max. differential pressure (alt 87 Hz) mfr | 420 mbar (87 Hz) |
| Weight | 55 kg (100 Hz) 87 Hz: 53 kg |
| Weight approx. mfr | 50 kg |
| Weight approx. mfr | 53 kg (87 Hz) |
| Current | 12.7 A (100 Hz) 87 Hz: 11.6 A |
| Frequency | 100 Hz |
| Power supply | 3~ 50/60 Hz, IP55, Insulation class F |
| Voltage | 400 V (100 Hz) 87 Hz: 380 V |
| Rated motor voltage mfr | 400 V (50 Hz) |
| Rated motor current mfr | 12.7 A (50 Hz) |
| Rated motor power mfr | 5.5 kW (50 Hz) |
| Rated motor voltage mfr | 380 V (60 Hz) |
| Rated motor current mfr | 11.6 A (60 Hz) |
| Rated motor power mfr | 5.8 kW (60 Hz) |
| Rated motor voltage mfr | 400 V (100 Hz) |
| Rated motor current mfr | 12.7 A (100 Hz) |
| Rated motor voltage mfr | 380 V (87 Hz) |
| Rated motor current mfr | 11.6 A (87 Hz) |
| Rated motor power mfr | 5.8 kW (87 Hz) |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 55 dB(A) (50 Hz) |
| Sound pressure level mfr | 55 dB(A) (60 Hz) |
| Sound pressure level mfr | 75/76 dB(A) (100 Hz) |
| Sound pressure level mfr | 80 dB(A) (87 Hz) |
| Sound pressure level (alt 100 Hz) mfr | 75/76 dB (100 Hz) |
Description
Construction and series positioning
- The 2BH7610 is a side-channel (regenerative) blower with an integrated frequency converter housed in an IP55 enclosure, configured for wall mounting.
- Within the G-BH7 series, sibling models 2BH721, 2BH7210, 2BH722, and 2BH7220 are listed without integrated VFD details; the 2BH7610 is the variant that embeds the drive electronics, eliminating a separate VFD cabinet.
- The data sheet covers 2BH7610-0A variants for 50 Hz, 87 Hz, and 60 Hz operation, with voltage variants 400 V and 380 V and VFD sizes A–K (2FC4xxx-1□□00).
Behavior under load and media
- Maximum differential pressure is 420 mbar in both vacuum and pressure modes at 50 Hz, rising to 440 mbar at 60 Hz.
- Motor ratings: 5.5 kW at 50 Hz (400 V, 12.7 A) and 5.8 kW at 60 Hz (380 V, 11.6 A).
- Sound pressure level is 55 dB(A) at both 50 Hz and 60 Hz.
- No digitized curve points are available; performance beyond the maximum differential pressure must be obtained from the manufacturer’s selection software or additional testing.
Installation, connection, and control
- The integrated frequency converter allows direct connection to the mains; the data sheet specifies VFD sizes A–K, but no further wiring or control-terminal details are provided in the digest.
- Wall mounting is specified; weight is approximately 50 kg, so structural fixing must be rated accordingly.
- No certificates or applications are listed in the verified facts; compliance and suitability for specific processes must be confirmed separately.
Integration & Operating Notes
The blower weighs approximately 50 kg; wall anchors and brackets must be rated for this static mass plus vibration and reaction torque during operation. Inadequate fixing risks loosening, noise, and damage to the integrated converter.
The 2BH7610-0A is offered with 400 V (50 Hz) or 380 V (60 Hz) motor ratings. The integrated frequency converter (IP55) is factory-matched to the motor; supply voltage and frequency must match the ordered variant to avoid derating or damage.
Maximum differential pressure is 420 mbar at 50 Hz and 440 mbar at 60 Hz in both vacuum and pressure modes. Operating above these limits can cause overheating, motor overload, or mechanical damage; the integrated converter’s settings must enforce this limit.
The data sheet lists VFD sizes A–K (2FC4xxx-1□□00) for the 2BH7610-0A. The specific size affects available control terminals and parameter set; the exact I/O and communication options must be taken from the VFD manual for the delivered size.
Selection & Integration Q&A
Choose 2BH7610 when you need an integrated frequency converter (IP55) for speed control without a separate VFD cabinet, and when 420–440 mbar differential pressure at 5.5–5.8 kW suits your duty. Siblings 2BH7210/2BH7220 are listed without integrated VFD details; select them if a bare blower with external drive is preferred or if their performance range matches better.
The 2BH7610-0A is available with 400 V (50 Hz) or 380 V (60 Hz) motor ratings and an integrated frequency converter (IP55). Supply voltage and frequency must match the ordered variant. The VFD size (A–K, 2FC4xxx-1□□00) is factory-matched; no external drive is required, but control wiring depends on the VFD size.
The unit is designed for wall mounting and weighs approximately 50 kg; the wall structure and fixings must support this mass plus dynamic loads. The integrated converter is IP55, so the enclosure is protected against dust and water jets, but ambient temperature limits and ventilation requirements are not specified in the available digest and must be confirmed with the manufacturer.
No maintenance schedule, service intervals, or accessory list is provided in the verified facts. The base delivery includes the blower with integrated frequency converter; cables, filters, silencers, and spare parts are not mentioned and must be specified separately. Consult the full instruction manual for maintenance requirements and optional accessories.