Elmo Rietschle 2BH1310
Elmo Rietschle 2BH1310 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -210 mbar, Motor power 0.83 kW, Noise level 61 dB.
The 2BH1310 is a side-channel (regenerative) blower in Elmo Rietschle's G-BH1 series, configured as a single-stage unit with a 1.49 kW (50 Hz) / 1.46 kW (60 Hz) motor and IP55 protection. It delivers up to 210 mbar differential pressure at 50 Hz and 250 mbar at 60 Hz in both vacuum and pressure modes, distinguishing it from smaller siblings like the 2BH1009 and 2BH1014 by higher pressure capability. It is used for contactless conveying, vacuum holding, and aeration in industrial systems where oil-free, pulsation-free air is required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1310 Current | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -210 mbar (50 Hz) 60 Hz: -250 mbar |
| Motor power | 0.70 kW (50 Hz) 60 Hz: 0.83 kW |
| Noise level | 56 dB (50 Hz) 60 Hz: 61 dB |
| Type mfr | 2BH1310-1HC23 (50 Hz) |
| Type mfr | 2BH1310-1HH26 (60 Hz) |
| Max. differential pressure — Vacuum (50 Hz) mfr | 210 mbar (50 Hz) |
| Max. differential pressure — Vacuum (60 Hz) mfr | 250 mbar (60 Hz) |
| Approvals mfr | UL 1450 and CAN/CSA 22.2 No 68-09 (certificate n |
| Rated pressure (vacuum) mfr | -210 mbar (50 Hz) |
| Rated pressure (vacuum) mfr | -250 mbar (60 Hz) |
| Order No. mfr | 2BH1310-1HH26 |
| Max. differential pressure (alt 50 Hz) mfr | 240 mbar (50 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 250 mbar (60 Hz) |
| Weight | 16 kg |
| Current | 3.8 Δ / 2.20 Y A (50 Hz) 60 Hz: 3.75 Δ / 2.15 Y A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 200-240 Δ / 345-415 Y V (50 Hz) 60 Hz: 220-275 Δ / 380-480 Y V |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level (50 Hz) mfr | 56 dB(A) (50 Hz) |
| Sound pressure level (60 Hz) mfr | 61 dB(A) (60 Hz) |
| Sound pressure level mfr | 56 dB(A) (50 Hz) |
| Sound pressure level mfr | 61 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH1310 is a single-stage side-channel blower with a cast aluminium housing and a dynamically balanced impeller directly mounted on the motor shaft. The motor is a 50/60 Hz AC induction motor with class F insulation and IP55 protection.
- Within the G-BH1 series, the 2BH1310 sits above the 2BH1009, 2BH1014, 2BH1015, and 2BH1023 in terms of maximum differential pressure (210 mbar at 50 Hz vs. lower values for smaller models). It is not a multi-stage unit; for higher pressures, larger or multi-stage models would be required.
- The model is available in two voltage variants: 2BH1310-1HC23 (50 Hz: 200–240 V Δ / 345–415 V Y) and 2BH1310-1HH26 (60 Hz: 220–275 V Δ / 380–480 V Y). Both are dual-frequency rated, but the actual supply must match the nameplate.
Behavior under load and in different media
- The blower can operate in either vacuum or pressure mode, with identical maximum differential pressures (210 mbar at 50 Hz, 250 mbar at 60 Hz). The symmetrical design means the same unit can be used for suction or discharge by simply reversing the inlet/outlet connections.
- The side-channel principle provides oil-free, contactless compression, making it suitable for handling air and neutral gases without contamination. The absence of internal lubrication means no carryover into the process.
- The motor power is 1.49 kW at 50 Hz and 1.46 kW at 60 Hz, with current draw of 3.8 A Δ / 2.20 A Y at 50 Hz and 3.75 A Δ / 2.15 A Y at 60 Hz. These values are for nominal conditions; actual current varies with operating point.
- Sound pressure level is 56 dB(A) at 50 Hz and 61 dB(A) at 60 Hz, measured at 1 m distance according to standard test conditions. No curve points are provided, so the pressure-flow characteristic must be obtained from the manufacturer's performance curves.
Installation, connection, and operation
- The blower is designed for horizontal mounting on a flat, vibration-dampening surface. The motor can be connected directly to the mains via a contactor or motor starter, with overload protection set according to the nameplate current. For variable speed, a VFD can be used, but the motor insulation is not specifically inverter-duty rated; consult Elmo Rietschle for VFD operation.
- The inlet and outlet are threaded ports (typically G 1¼ or similar, to be confirmed from dimensional drawing). Piping should be supported independently to avoid stress on the blower housing. A flexible connector is recommended to isolate vibration.
- The blower is not suitable for handling explosive atmospheres unless specifically certified (no such certification is listed). The IP55 protection allows outdoor installation with additional cover, but the standard unit is for indoor use.
- The technical data sheet covers the 2BH1310-1HH26 and 2BH1310-1HC23 variants, plus alternate-voltage motor options for 2BH1310-..□.□. No additional manuals or certificates are provided in the digests.
Integration & Operating Notes
The 2BH1310-1HC23 is wound for 200–240 V Δ / 345–415 V Y at 50 Hz, while the 2BH1310-1HH26 is for 220–275 V Δ / 380–480 V Y at 60 Hz. Applying the wrong voltage or frequency will cause overheating, reduced torque, or immediate failure. Verify the nameplate before connection and ensure the supply frequency matches the motor rating.
Selection & Integration Q&A
Choose the 2BH1310 when your process requires up to 210 mbar (50 Hz) or 250 mbar (60 Hz) differential pressure. The 2BH1009 and 2BH1014 offer lower maximum pressure, so they are suitable for lower-pressure applications. The 2BH1310 also provides higher flow at these pressures, but verify the exact operating point against the performance curve.
Use a contactor or motor starter rated for the motor current: 3.8 A Δ / 2.20 A Y at 50 Hz or 3.75 A Δ / 2.15 A Y at 60 Hz. Set the overload relay to the nameplate current. For delta connection, ensure the supply voltage matches the delta rating. A thermal overload relay with Class 10 trip curve is recommended. If using a VFD, consult the manufacturer for inverter compatibility.
The IP55 rating provides protection against dust and water jets, so it can be installed outdoors if protected from direct rain and splashing. However, the standard motor is not designed for continuous condensation. Provide a drip cover and ensure the drain holes are open. Ambient temperature range is typically -20 to +40 °C; check the manual for derating above 40 °C.
The base delivery includes the blower only. You must separately order flexible connectors, inlet/outlet flanges or threaded adapters, a suction filter (if needed), a pressure relief valve, and mounting feet or anti-vibration pads. Electrical cables and motor protection devices are also not included. Refer to the accessory list in the technical data sheet for part numbers.