Elmo Rietschle 2BH1910
Elmo Rietschle 2BH1910 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270 mbar, Motor power 12.6 kW, Noise level 76 dB.
The 2BH1910 is a side-channel (regenerative) blower in Elmo Rietschle's G-BH1 series, driven by a 21.3 kW IE3 motor for 50 Hz operation. It delivers up to 480 mbar differential pressure in pressure mode and -440 mbar in vacuum mode, with a 317 kg cast construction and IP55 protection. This model is the higher-power option in the series, suited for continuous industrial vacuum or pressure duty where moderate flow and high differential are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1910 Current | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -270 mbar (50 Hz) 60 Hz: -220 mbar |
| Motor power | 12.6 kW (50 Hz) 60 Hz: 14.5 kW |
| Noise level | 72 dB (50 Hz, IE3) 60 Hz, IE3/NP: 76 dB |
| Max. differential pressure vacuum mfr | -440 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -440 mbar (60 Hz) |
| Order No. mfr | 2BH1910-1HQ36 |
| Order No. mfr | 2BH1910-1HQ16 (50 Hz) |
| Order No. mfr | 2BH1910-1HK16 (60 Hz) |
| Approvals mfr | UL and CSA approved |
| Operating mode mfr | continuous operation |
| Max. differential pressure (pressure) (alt 50 Hz) mfr | 240 mbar (50 Hz) |
| Max. differential pressure (pressure) (alt 60 Hz) mfr | 190 mbar (60 Hz) |
| Weight | 295 kg (IE3) |
| Number of stages | 1 |
| Weight approx. mfr | 317 kg |
| Weight approx. mfr | 240 kg (50 Hz) |
| Weight approx. mfr | 190 kg (60 Hz) |
| Weight approx. mfr | 190 kg (60 Hz NEMA) |
| Current | 46.4 A (50 Hz, 190-210 VΔ) 60 Hz, 190-210 VYY / 380-420 VY: 52.8 A · 60 Hz, 190-210 VYY / 380-420 VY (low): 26.4 A · 60 Hz, 200 VYY: 52.8 A |
| Power supply | 3~ 50/60 Hz |
| Voltage mfr | 220-240 / 380-420 V (50 Hz) |
| Voltage mfr | 440-480 V (60 Hz) |
| Rated current mfr | 66.3 Δ / 38.3 Y A (50 Hz) |
| Rated current mfr | 38.0 Y A (60 Hz) |
| Efficiency class mfr | IE3 |
| Mains frequency mfr | 50/60 Hz |
| Voltage tolerance mfr | ±10 % |
| Frequency tolerance mfr | ±2 % |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Voltage mfr | 460 V (60 Hz NEMA) |
| Efficiency class mfr | NP (60 Hz NEMA) |
| Protection rating | IP55 |
| Sound pressure level mfr | 72 dB(A) |
| Sound pressure level mfr | 72 dB(A) (50 Hz) |
| Sound pressure level mfr | 76 dB(A) (60 Hz) |
| Sound pressure level mfr | 76 dB(A) (60 Hz NEMA) |
Description
Construction and series positioning
- The 2BH1910 is a regenerative ring blower with a cast housing and directly coupled IE3 induction motor, rated IP55 and insulation class F. At 317 kg, it is a heavy-duty frame size within the G-BH1 series.
- Compared to sibling models 2BH1009, 2BH1014, 2BH1015 and 2BH1023, the 2BH1910 offers the highest motor power (12.6 kW at 50 Hz) and correspondingly higher differential pressure capability, making it the choice when the application demands maximum pressure or vacuum within the series.
- The blower is designed for both pressure and vacuum operation, with maximum differential pressures of 480 mbar (pressure) and -440 mbar (vacuum) at 50 Hz. At 60 Hz, pressure capability drops to 410 mbar while vacuum remains at -440 mbar.
Behavior under load and media
- The machine uses a non-contact impeller running in a ring channel, so no internal lubrication is required and the conveyed medium is not contaminated by oil. This makes it suitable for air and neutral gases.
- The pressure and vacuum limits are differential values; actual achievable flow depends on system resistance. No digitized curve points were provided, so performance must be verified against the manufacturer's published curves for the specific speed and gas.
- The motor is rated for continuous duty (S1) and can operate at mains frequencies of 50 or 60 Hz with voltage tolerance of ±10% and frequency tolerance of ±2%. At 60 Hz, the higher speed increases power draw to 14.5 kW and changes the pressure limits as noted.
Installation, connection and control
- Electrical connection is via terminal box with Δ/Y configuration: 220–240 V Δ / 380–420 V Y at 50 Hz, and 440–480 V Y at 60 Hz. Rated current is 66.3 A in delta and 38.3 A in star at 50 Hz; 38.0 A in star at 60 Hz.
- The blower must be mounted on a flat, rigid surface using the provided mounting feet. Ensure sufficient clearance for cooling air intake and exhaust. The IP55 protection allows outdoor installation; ensure ambient temperature does not exceed motor limits.
- Control is typically via a contactor or soft starter; the high starting current of the IE3 motor (direct-on-line starting) may require a soft starter or star-delta starter to limit inrush.
- The sound pressure level is 72 dB(A) at nominal conditions; additional silencing may be required depending on installation environment.
Integration & Operating Notes
The motor is designed for ±10% voltage tolerance and ±2% frequency tolerance. Exceeding these limits can cause overheating, reduced insulation life, or immediate failure. Confirm the site supply matches the nameplate configuration (Δ or Y) and that the correct overload protection is set to the rated current for the chosen connection.
The 317 kg weight and dynamic forces require a solid mounting surface. Ensure the blower is level and bolted down to prevent vibration. Maintain at least the minimum clearance around the cooling air inlet and outlet as specified in the manual to avoid recirculation of hot air. The IP55 rating permits outdoor installation.
Direct-on-line starting of the 12.6 kW motor will draw high inrush current (typically 6-8 times rated). This can cause voltage dips and trip upstream protection. A star-delta starter or soft starter is recommended to reduce starting current and mechanical shock. Ensure the starter is rated for the motor power and set the overload relay to the rated current for the selected connection.
Because the blower handles air, dust and particles can accumulate on the impeller and in the inlet, causing imbalance and reduced performance. Inspect and clean the impeller and inlet screen at intervals determined by the contamination level of the process air. Replace the inlet filter (if fitted) when pressure drop increases. Bearings are sealed and require no lubrication.
Selection & Integration Q&A
Choose the 2BH1910 when your required differential pressure is near 480 mbar (pressure) or -440 mbar (vacuum) and flow demands are moderate. The 2BH1023 offers lower power and pressure. Select based on the intersection of your system curve with the blower curve.
The 2BH1910 requires a 3-phase supply matching the nameplate voltage (e.g., 380–420 V Y at 50 Hz) with ±10% voltage and ±2% frequency tolerance. Use a motor protection circuit breaker or overload relay set to 38.3 A (Y at 50 Hz) or 66.3 A (Δ at 50 Hz). A soft starter or star-delta starter is recommended to limit inrush current.
Regular maintenance includes cleaning the impeller and inlet filter (if fitted) and checking for vibration. Bearings are sealed for life. No consumables are included in the base delivery; inlet filters, silencers, and flexible connectors must be ordered separately. Refer to the manual for specific intervals based on operating conditions.