Elmo Rietschle 2BH1510
Elmo Rietschle 2BH1510 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -400 mbar, Motor power 3.45 kW, Noise level 71 dB.
The 2BH1510 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by an IE3 efficiency-class motor. It delivers 410 m³/h suction capacity and achieves a maximum vacuum of -370 mbar at 50 Hz (-400 mbar at 60 Hz) or a maximum pressure of 380 mbar, making it suitable for vacuum or pressure duty in industrial processes. Its IP55 protection and F-class insulation support reliable operation in demanding environments.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1510 Current | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -370 mbar (50 Hz) 60 Hz: -400 mbar |
| Motor power | 3.45 kW (50 Hz) 60 Hz: 4.0 kW |
| Noise level | 71 dB (50 Hz) 60 Hz: 73 dB |
| Suction capacity mfr | 410 m3/h (50 Hz, vacuum, 60 Hz? see doc) |
| Max. differential pressure vacuum mfr | -400 mbar (60 Hz) |
| Order No. mfr | 2BH1510-1HQ46 |
| Vacuum mfr | -370 mbar (50 Hz) |
| Order No. mfr | 2BH1510-1HQ57 (50 Hz) |
| Vacuum mfr | -410 mbar (60 Hz) |
| Order No. mfr | 2BH1510-1HQ57 (60 Hz) |
| Approvals mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Pressure (alt 50 Hz) mfr | 410 mbar (50 Hz) |
| Pressure (alt 60 Hz) mfr | 380 mbar (60 Hz) |
| Weight | 48 kg (50 Hz) 60 Hz: 48 kg |
| Current | 13.3 A (50 Hz) 60 Hz: 15.2 / 7.6 A |
| Frequency | 50/60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Power consumption at pump shaft mfr | 3.45 kW (50 Hz) |
| Power consumption at pump shaft mfr | 4.0 kW (60 Hz) |
| Efficiency class mfr | IE3 |
| Efficiency class mfr | NP (NEMA Premium) (60 Hz) |
| Efficiency class mfr | IE3 (50 Hz) |
| Voltage tolerance mfr | ±10 % (three-phase motors) |
| Frequency tolerance mfr | ±2 % |
| Voltage (alt 60 Hz) mfr | 230 / 460 V (60 Hz) |
| Current (alt 60 Hz) mfr | 13.2 / 6.6 A (60 Hz) |
| Voltage (alt 50 Hz) mfr | 220-240 / 380-420 V (50 Hz) |
| Current (alt 50 Hz) mfr | 11.6 / 6.7 A (50 Hz) |
| Protection rating | IP55 |
| Sound pressure level mfr | 70 dB(A) (50 Hz) |
| Sound pressure level mfr | 73 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH1510 is a single-stage (No. 1) side-channel blower, as indicated by the data sheet covering both single- and two-stage variants. This model is the higher-capacity unit within the G-BH1 series, positioned above siblings such as the 2BH1009, 2BH1014, 2BH1015, and 2BH1023.
- It uses an IE3 motor with IP55 protection and insulation class F, available for 50/60 Hz operation with dual voltage ratings (220–240 V Δ / 380–420 V Y at 50 Hz; 440–480 V Y at 60 Hz).
- The order number 2BH1510-1HQ46 identifies this specific configuration; other order numbers in the data sheet refer to different voltage/frequency combinations or stage counts.
Performance and behavior
- At 50 Hz, the blower provides 410 m³/h suction capacity, a maximum vacuum of -370 mbar, and a maximum pressure of 380 mbar. At 60 Hz, vacuum increases to -400 mbar while pressure remains 380 mbar.
- Power consumption at the pump shaft is 3.45 kW at 50 Hz and 4.0 kW at 60 Hz. Sound pressure level is 71 dB(A) at 50 Hz and 73 dB(A) at 60 Hz.
- The unit weighs approximately 48 kg. No digitized curve points are available, so performance beyond the stated maxima should be verified with the manufacturer's curves.
Installation and operation
- The data sheet does not provide detailed installation instructions, but the IP55 rating and insulation class F indicate suitability for dusty and humid environments. The motor is designed for direct-on-line starting or star-delta starting (dual voltage).
- Electrical connection must match the voltage and frequency; the current draw is 11.6 A in delta and 6.7 A in star at 50 Hz, and 6.6 A in star at 60 Hz.
- The blower can be used for either vacuum or pressure operation, but the maximum differential pressures differ; ensure the process does not exceed these limits.
Integration & Operating Notes
Exceeding the rated current can overheat the motor and damage insulation. The IE3 motor draws 11.6 A in delta (220–240 V) and 6.7 A in star (380–420 V) at 50 Hz; at 60 Hz, 6.6 A in star (440–480 V). Ensure protection devices are set accordingly and account for inrush current.
Operating beyond these vacuum levels may cause overheating or mechanical stress. The maximum pressure is 380 mbar for both frequencies. Use a vacuum relief valve or pressure relief valve to prevent exceeding these limits, especially during transient conditions or blockages.
Dust and debris can accumulate on the impeller, reducing performance and causing imbalance. The data sheet does not specify maintenance intervals, but typical practice for side-channel blowers is to check every 500 operating hours and clean or replace the filter as needed. Bearings are sealed and require no lubrication.
Selection & Integration Q&A
Choose the 2BH1510 when your process requires up to 410 m³/h suction capacity and vacuum to -370 mbar (50 Hz) or -400 mbar (60 Hz). Smaller siblings like the 2BH1023 offer lower capacity and are better for lower flow demands. The 2BH1510 also provides higher pressure (380 mbar) and is IE3 rated for energy efficiency.
The motor is dual-voltage: 220–240 V Δ / 380–420 V Y at 50 Hz, or 440–480 V Y at 60 Hz. Use a motor protection circuit breaker set to the rated current (11.6 A Δ or 6.7 A Y at 50 Hz; 6.6 A Y at 60 Hz). Ensure the supply can handle the starting current, and consider a soft starter or star-delta starter for larger installations.
The IP55 rating allows operation in dusty and humid environments, but the blower should be protected from direct water jets and ensure ambient temperature does not exceed the motor's rating (typically 40°C). Provide sufficient ventilation to dissipate heat, especially when operating near maximum pressure or vacuum.
The base delivery includes the blower only. Recommended accessories include inlet filters, vacuum/pressure relief valves, and flexible connectors to reduce vibration. Maintenance items include replacement filters and periodic inspection of the impeller. No specific maintenance schedule is provided in the data sheet; follow general practice for side-channel blowers.