Elmo Rietschle 2BH1943
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1943

Elmo Rietschle 2BH1943 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 19.9 kW, Noise level 77 dB.

The 2BH1943 is a side-channel blower from the G-BH1 series, driven by a 17.3 kW IE3 motor for 50 Hz operation (19.9 kW at 60 Hz). It delivers up to 170 mbar differential pressure and -160 mbar vacuum at 50 Hz, with lower limits at 60 Hz. This model is intended for high-demand vacuum or pressure applications in industrial systems.

Max. differential pressure
-160 mbar
Motor power
19.9 kW
Noise level
77 dB
Weight
330 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1943 Current 17.377330-16072.2 UU / 36.1 UIP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -160 mbar (50 Hz, variant 1GK21)
60 Hz, variant 1GK21: -120 mbar
Motor power 17.3 kW (50 Hz, variant 1GK21)
60 Hz, variant 1GK21: 19.9 kW
Noise level 73 dB(A) (50 Hz, variant 1GK21)
60 Hz, variant 1GK21: 77 dB(A)
Series mfr G-BH 1 N
Type mfr 2BH1943-1GQ37 (50 Hz)
Type mfr 2BH1943-1GQ37 (60 Hz)
Max. differential pressure Vacuum mfr -120 mbar (60 Hz)
Approvals mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Max. differential pressure (alt 50 Hz, variant 1GK21) mfr 170 mbar (50 Hz, variant 1GK21)
Max. differential pressure (alt 60 Hz, variant 1GK21) mfr 110 mbar (60 Hz, variant 1GK21)
Dimensions, Weight & Mechanical Design
Weight 330 kg (variant 1GK21)
Number of stages 1 (variant 1GK21)
Weight approx. mfr 342 kg (60 Hz)
Electrical, Power & Drive Specifications
Current 63.1 D A (50 Hz, variant 1GK21)
60 Hz, variant 1GK21: 72.2 UU / 36.1 U A
Power supply 3~ 50/60 Hz
Voltage 190-210 D V (50 Hz, variant 1GK21)
60 Hz, variant 1GK21: 190-210 UU / 380-420 U V
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr IE3 (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature up to 25 degC
Sound pressure level mfr 73 dB(A) (50 Hz)
Sound pressure level mfr 77 dB(A) (60 Hz)

Description

Construction and positioning

Performance behavior

Installation and operation

Integration & Operating Notes

Electrical
Ensure motor protection matches 31.7 A at 50 Hz delta

The full-load current at 50 Hz in delta connection is 31.7 A. Select cables, contactors, and overload relays for at least this current, and consider the higher starting current. At 60 Hz, the current is 31.4 A in delta. Incorrect protection can lead to motor overheating or nuisance tripping.

Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN), Edition 12/2020
Mounting
Provide unobstructed cooling air flow to prevent overheating

The motor relies on fan cooling. Install the blower with sufficient clearance around the cooling air inlet and outlet, and avoid recirculating hot air. In enclosed spaces, ensure adequate ventilation or ducting to maintain ambient temperature within the motor's rating.

Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN), Edition 12/2020
Process Limits
Do not exceed 170 mbar pressure or -160 mbar vacuum at 50 Hz

Operating beyond these differential pressure limits can cause excessive heating, increased noise, and mechanical stress, potentially damaging the blower. At 60 Hz, the limits are 110 mbar pressure and -120 mbar vacuum. Always verify the actual operating point against the performance curve.

Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN), Edition 12/2020
Control & I/O
Use star-delta starting or soft starter to limit inrush current

Direct-on-line starting of a 17.3 kW motor may cause significant voltage dips. If the supply is weak, use star-delta starting (possible with dual-voltage motor) or a soft starter. Ensure the starting method is compatible with the load characteristics of the blower.

Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN), Edition 12/2020
Maintenance
Regularly inspect and clean cooling fins and air filters

Dust accumulation on cooling fins reduces heat dissipation and can lead to motor overheating. If an inlet filter is used, clean or replace it according to the manufacturer's schedule. No specific maintenance intervals are provided in the data sheet; follow general good practice.

Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN), Edition 12/2020

Selection & Integration Q&A

When should I choose the 2BH1943 over smaller models like the 2BH1023?

Choose the 2BH1943 when your process requires differential pressures up to 170 mbar or vacuum to -160 mbar at 50 Hz, and flow rates that the smaller models cannot achieve. The 2BH1023 and others in the series have lower capacity. If your demand is below 100 mbar, a smaller model may be more efficient and cost-effective.

What are the requirements for the electrical supply and protection when installing this blower?

The motor requires a 3-phase supply of 380-420 V (delta) or 660-725 V (star) at 50 Hz, or 440-480 V (delta) at 60 Hz. Use motor protection rated for 31.7 A (50 Hz) or 31.4 A (60 Hz). Ensure the supply can handle starting current; consider star-delta starting. Cables and components must be rated for the full load current and voltage.

What environmental conditions and duty cycle are permissible for the 2BH1943?

The blower has IP55 protection, so it can operate in dusty and wet environments. However, ambient temperature must not exceed the motor's rating (typically 40°C). Continuous operation at maximum differential pressure may cause overheating; ensure adequate cooling. No specific duty cycle is given, but the motor is designed for continuous operation (S1) under rated conditions.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower only. You must provide electrical cables, motor protection, and any piping or fittings. Optional accessories such as inlet filters, silencers, or non-return valves are not included and should be ordered separately. Regular maintenance includes cleaning cooling fins and checking for wear; no specific spare parts list is provided in the data sheet.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1943 IE3 vacuum pump (EN)
Datasheet ·727,2 КБ ·2 pp.
View PDF