Elmo Rietschle 2BH1023
Elmo Rietschle 2BH1023 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -190 mbar, Motor power 1.75 kW, Noise level 70 dB.
The 2BH1023 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by a single-phase 115/230 V motor rated 1.75 kW at 50 Hz and 1.5 kW at 60 Hz. It delivers up to 200 mbar differential pressure in compressor mode and -190 mbar in vacuum mode at 50 Hz, positioning it above the 2BH1009/1014/1015 siblings but below the 2BH1035. Its IP55, Class F motor and 31 kg frame make it suited for continuous-duty pressure or vacuum supply in industrial processes.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1023 Current | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -190 mbar (50 Hz) 60 Hz: -180 mbar |
| Motor power | 1.5 kW (50 Hz) 60 Hz: 1.75 kW |
| Noise level | 69 dB (50 Hz) 60 Hz: 70 dB |
| Max. differential pressure compressor mfr | 200 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -180 mbar (60 Hz) |
| Max. differential pressure compressor mfr | 180 mbar (60 Hz) |
| Order number mfr | BH1023-1AAA-HV4-BA0 (50 Hz) |
| Order number mfr | BH1023-1AAA-HV4-BA0 (60 Hz) |
| Max. Differenzdruck Verdichter (alt 50 Hz) mfr | 200 mbar (50 Hz) |
| Max. Differenzdruck Verdichter (alt 60 Hz) mfr | 180 mbar (60 Hz) |
| Weight | 69 kg (50 Hz) 60 Hz: 70 kg |
| Number of stages | 1 |
| Weight approx. mfr | 31 kg |
| Current | 19.0 / 9.5 A (50 Hz) 60 Hz: 20.0 / 10.0 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 115 / 230 V (50 Hz) 60 Hz: 115 / 230 V |
| Rated current mfr | 20.0 / 10.0 A (60 Hz) |
| Rated power mfr | 1.75 kW (60 Hz) |
| Voltage tolerance mfr | ±5 % (1~ motors) |
| Protection rating | IP55 |
| Cooling type | F |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 69 dB(A) (50 Hz) |
| Sound pressure level mfr | 70 dB(A) (60 Hz) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with a single-phase, 115/230 V motor; two order codes cover 50 Hz (BH1023-1AAA-HV5-BA0) and 60 Hz (BH1023-1AAA-HV4-BA0) operation.
- Within the G-BH1 series, the 2BH1023 sits between the smaller 2BH1009/1014/1015 and the larger 2BH1035; the comparison is on differential pressure only, as no flow data is available.
- Motor is IP55 protected and Class F insulated, with ±5 % voltage tolerance on the single-phase winding.
Performance behaviour
- At 50 Hz the unit reaches -190 mbar vacuum and +200 mbar compressor differential pressure; at 60 Hz these fall to -180 mbar and +180 mbar respectively.
- Rated power is 1.5 kW at 50 Hz and 1.75 kW at 60 Hz, with corresponding currents of 19.0/9.5 A (50 Hz) and 20.0/10.0 A (60 Hz) at 115/230 V.
- Sound pressure level is 69 dB(A) at 50 Hz and 70 dB(A) at 60 Hz, measured at the standard factory condition.
Installation and operation
- The blower is intended for horizontal mounting on a rigid base; the 31 kg mass and single-phase motor require attention to vibration isolation and starting current.
- Electrical connection must respect the dual-voltage winding: 115 V or 230 V at 50/60 Hz, with supply tolerance limited to ±5 %.
- No digitized curve points or application-specific certificates are supplied with this model; performance outside the stated maximum differential pressures is not defined by the available data.
Integration & Operating Notes
The single-phase motor is wound for 115 V or 230 V at 50/60 Hz with a ±5 % tolerance. Exceeding this range risks overheating and reduced insulation life; a stabilised supply or buck-boost transformer should be considered where grid variation is common.
These are the maximum differential pressures for this model at 50 Hz; at 60 Hz the limits reduce to 180 mbar in both modes. Operating beyond them raises motor load and temperature, and the available data does not define behaviour outside these limits.
The blower should be bolted to a flat, rigid surface to avoid frame distortion and excess vibration. Because the motor is single-phase, vibration and torque pulsation are higher than for three-phase drives; flexible mounts or a resilient base can reduce transmission to the pipework.
The datasheet lists only the blower and motor; inlet filters, silencers, flexible connectors and mounting feet must be ordered separately. Periodic inspection should cover motor bearings, impeller clearance and housing fasteners, but no specific service interval is stated in the available documentation.
Selection & Integration Q&A
Pick the 2BH1023 when you need up to 200 mbar pressure or -190 mbar vacuum at 50 Hz from a single-phase 115/230 V supply. The 1009/1014/1015 are smaller and lower-pressure; the 2BH1035 is larger and higher-capacity. Choose this model for mid-range duty where the 1035 would be oversized.
A 115 V or 230 V single-phase supply within ±5 %, capable of at least 19.0 A at 115 V (9.5 A at 230 V) at 50 Hz, or 20.0 A at 115 V (10.0 A at 230 V) at 60 Hz. Use motor protection rated for the starting current, and ensure the circuit can handle the locked-rotor surge of a 1.75 kW single-phase motor.
Mount horizontally on a rigid, level base; the 31 kg mass and single-phase vibration call for secure bolting and possibly flexible mounts. The datasheet gives IP55 and Class F insulation but no ambient temperature range, so site conditions should be confirmed with the manufacturer.
The base delivery is the blower only; inlet filters, silencers, flexible connectors and mounting feet are separate. No service interval is specified in the datasheet, so bearing and impeller inspection should be scheduled per site experience, with particular attention to the single-phase motor's start capacitor if fitted.