Elmo Rietschle 2BH1410
Elmo Rietschle 2BH1410 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -310 mbar, Motor power 2 kW, Noise level 68 dB.
The 2BH1410 is a side-channel blower from the G-BH1 series, driven by a 3-phase IE3 motor rated 2.50 kW at 50 Hz and 3.00 kW at 60 Hz. It delivers a maximum differential pressure of 420 mbar in pressure mode and -320 mbar in vacuum mode at 50 Hz, with 60 Hz operation extending these to 440 mbar and -350 mbar. This modification is positioned as a mid-range unit in the series, suited for continuous industrial vacuum or pressure duty where IE3 efficiency and IP55 protection are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1410 Current | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -310 mbar (50 Hz) 60 Hz: -300 mbar |
| Motor power | 1.75 kW (50 Hz) 60 Hz: 2.00 kW |
| Noise level | 65 dB (50 Hz) 60 Hz: 68 dB |
| Max. differential pressure vacuum mfr | -300 mbar (60 Hz) |
| Certification mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Order No. mfr | 2BH1410-0HK31 |
| Max. differential pressure (alt 50 Hz) mfr | 280 mbar (50 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 250 mbar (60 Hz) |
| Weight | 28 kg |
| Number of stages | 1 |
| Current | 6.9 A (50 Hz) 60 Hz: 7.8 / 3.9 A |
| Frequency | 50/60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Rated voltage mfr | 220-240 Δ / 380-420 Y V (50 Hz) |
| Rated voltage mfr | 440-480 Y V (60 Hz) |
| Rated current mfr | 8.8 Δ / 5.1 Y A (50 Hz) |
| Rated current mfr | 5.2 A (60 Hz) |
| Power consumption at pump shaft mfr | 2.50 kW (50 Hz) |
| Power consumption at pump shaft mfr | 3.00 kW (60 Hz) |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Ambient temperature limit | 25 degC |
| Protection rating | IP55 |
| Sound pressure level mfr | 65 dB(A) (50 Hz) |
| Sound pressure level mfr | 68 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH1410 is a single-stage side-channel (regenerative) blower with an integrated IE3 three-phase motor (IE3 at 50 Hz; NP at 60 Hz), housed in an IP55 enclosure with class F insulation.
- Within the G-BH1 series, it sits between the smaller 2BH1009/2BH1014/2BH1015 and the larger 2BH1023, offering a balanced pressure/flow envelope for medium-duty applications.
- The motor is designed for dual frequency (50/60 Hz) and dual voltage (220–240 Δ / 380–420 Y at 50 Hz; 440–480 Y at 60 Hz), allowing global deployment without motor replacement.
Performance and operating behavior
- At 50 Hz, the unit achieves a maximum pressure differential of 280 mbar and a vacuum differential of -310 mbar; at 60 Hz, these are 250 mbar and -300 mbar respectively.
- Power consumption at the pump shaft is 2.50 kW at 50 Hz and 3.00 kW at 60 Hz, reflecting the higher speed and load at 60 Hz.
- Sound pressure level is 65 dB(A) at 50 Hz and 68 dB(A) at 60 Hz, a 3 dB increase that must be considered for acoustic planning.
- No digitized curve points are available in the provided facts; performance curves should be requested from the manufacturer for precise flow-pressure mapping.
Installation and operation
- The blower is supplied without a drive or controller; it requires a suitable three-phase supply and motor protection. The IE3 motor is not inverter-duty rated by default; consult Elmo Rietschle before using a VFD.
- The IP55 protection allows outdoor installation but the motor cooling air intake must remain unobstructed. The unit weighs approximately 28 kg and should be mounted on a flat, vibration-damped surface using the provided mounting points.
- The data sheet covers sizes 1 and 2 with several voltage/frequency variants; the 2BH1410 is one specific variant within this range. No certificates beyond UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate number E225239) are listed.
Integration & Operating Notes
The IE3 motor is designed for direct-on-line operation at 50 or 60 Hz. If variable speed control is required, the motor insulation and bearing currents must be evaluated; Elmo Rietschle must be consulted to confirm suitability and any derating. Unapproved VFD use can cause winding failure or reduced bearing life.
At 50 Hz, the maximum pressure differential is 280 mbar and vacuum differential is -310 mbar. At 60 Hz, these are 250 mbar and -300 mbar. Operating beyond these limits will cause overheating and potential motor overload. Ensure the system's pressure relief or bypass is set below these values.
The blower weighs approximately 28 kg and generates vibration during operation. Mount on a flat, rigid surface using the designated mounting holes. Use anti-vibration mounts if the unit is installed near sensitive equipment or in a structure that could transmit vibration. Ensure the motor cooling air intake and exhaust are not restricted.
The IP55 rating protects against dust and water jets, allowing outdoor installation. However, the motor cooling air path must remain clear, and the unit should be shielded from direct sunlight and heavy rain to prevent condensation inside the motor. Ambient temperature limit is 25 °C per the data sheet; consult the manual for any additional conditions.
The provided data sheet does not list maintenance intervals or consumables. In practice, inspect and clean the impeller and inlet filter regularly, check motor bearings for noise and play, and verify electrical connections annually. Refer to the full instruction manual for detailed service schedules and spare parts.
Selection & Integration Q&A
Choose the 2BH1410 when your required pressure differential is up to 280 mbar (50 Hz) or 250 mbar (60 Hz) and vacuum differential is up to -310 mbar (50 Hz) or -300 mbar (60 Hz), and flow demand fits its mid-range envelope. The 2BH1014 offers lower power and pressure, while the 2BH1023 provides higher capacity. Select based on your system's pressure-flow operating point, not just maximum ratings.
The IE3 motor is not inverter-duty rated as standard. Using a VFD may require additional motor insulation, bearing protection, and derating. Consult Elmo Rietschle before installing a VFD; unapproved use can void warranty and cause premature failure.
The data sheet lists an ambient temperature limit of 25 °C. Duty cycle is not specified in the provided facts; the motor is rated for continuous duty (S1) at the stated power, but actual limits depend on cooling and altitude. Refer to the full instruction manual for any altitude derating and additional conditions.
The base delivery includes the blower only; power cables, motor protection, and mounting hardware are not included. No maintenance schedule is provided in the data sheet. Regularly inspect and clean the impeller and motor cooling passages, and check electrical connections. Consult the manual for detailed service intervals.