Elmo Rietschle 2BH1430
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1430

Elmo Rietschle 2BH1430 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 100 mbar, Motor power 0.95 kW, Noise level 61 dB.

The 2BH1430 is a side-channel blower from the G-BH1 series, driven by a 1.60 kW IE3/NP motor for 60 Hz operation (230 YY / 460 Y) and 1.30 kW for 50 Hz (190–210 V). It delivers a maximum differential pressure of -190 mbar in vacuum and 170 mbar in pressure at 60 Hz, with continuous operation permitted across the entire performance curve. This modification is positioned as a mid-range unit within the series, suited for pneumatic conveying, suction holding, or aeration duties where a compact, UL/CSA-approved blower is required.

Max. differential pressure
100 mbar
Motor power
0.95 kW
Noise level
61 dB
Weight
16 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1430 Current 1.164161104.2IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 110 mbar (50 Hz)
60 Hz: 100 mbar
Motor power 0.95 kW (50 Hz)
60 Hz: 1.10 kW
Noise level 61 dB (50 Hz)
60 Hz: 64 dB
Series mfr G-BH 1 N
Product type mfr Side channel blower with IE3-motors
Operation modes mfr Vacuum pump and compressor, continuous operation
Approvals mfr UL and CSA approved; UL 1450 and CAN/CSA C22.2 N
Performance curve basis mfr Air at 15 °C and atmospheric pressure 1013 mbar,
Total pressure difference validity mfr Suction and ambient temperature up to 25 °C
Type No. mfr 2BH1430-0AK26
Max. differential pressure Vacuum mfr -190 mbar (60 Hz)
Max. differential pressure Vacuum mfr -100 mbar (50 Hz)
Vacuum mfr -110 mbar (50 Hz)
Vacuum mfr -100 mbar (60 Hz)
Order No. mfr 2BH1430-0AK11 (50/60 Hz)
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Dimensions, Weight & Mechanical Design
Weight 16 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 4.2 A (50 Hz)
60 Hz: 4.8 / 2.4 A
Frequency 50/60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Voltage tolerance (three phase motors) mfr ±10 %
Frequency tolerance mfr ±2 %
Efficiency class mfr NP (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Voltage tolerance mfr +/-10 % (three phase motors)
Frequency tolerance mfr +/- 2 % (maximum)
Voltage (alt 60 Hz) mfr 200 V (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 64 dB(A) (60 Hz)
Sound pressure level mfr 61 dB(A) (50 Hz)
Sound pres. Level mfr 61 dB(A) (50 Hz)
Sound pres. Level mfr 64 dB(A) (60 Hz)
Standards, Safety & General Data
Converter input voltage suitability (standard motor insulation) mfr up to 500 V
Motor efficiency standard mfr NEMA MG1-12; NP=NEMA Premium; NEMA Premium inclu

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and control

Integration & Operating Notes

Electrical
External motor protection required; no built-in overload

The blower motor does not include internal thermal protection. The engineer must install a contactor or overload relay set to the rated current (5.5 A at 60 Hz, 5.6 A at 50 Hz) to prevent winding damage from overload or phase loss. The UL/CSA approval covers the motor only when protected according to the manual.

Technical Data Sheet — 2BH1430 IE3 vacuum pump (EN), Electrical Data
Process Limits
Pressure ratings valid only up to 25 °C inlet and ambient

The published maximum differential pressures (-190 mbar vacuum, 170 mbar pressure at 60 Hz) are based on air at 15 °C and are valid only when suction and ambient temperatures do not exceed 25 °C. Higher temperatures reduce the achievable pressure and may cause motor overload due to reduced air density. For hot gas applications, derate the blower or consult the manufacturer.

Technical Data Sheet — 2BH1430 IE3 vacuum pump (EN), Performance Data
Mounting
Ensure unobstructed cooling air and horizontal mounting

The IP55 motor relies on free convection over its fins. Install the blower with the motor axis horizontal and provide at least 100 mm clearance around the cooling air inlet and outlet. Avoid recirculation of hot discharge air into the motor cooling intake, which can cause overheating. Secure the blower to a rigid base to minimize vibration.

Technical Data Sheet — 2BH1430 IE3 vacuum pump (EN), Installation
Maintenance
Periodic inspection of bearings and seals recommended

The blower uses grease-lubricated bearings and contact seals. Under normal operating conditions, inspect bearings every 10,000 hours and replace if noise or vibration increases. Check the seal between the impeller and housing for wear if performance drops. Keep the cooling fins clean to maintain heat dissipation.

Technical Data Sheet — 2BH1430 IE3 vacuum pump (EN), Maintenance

Selection & Integration Q&A

When should I choose the 2BH1430 over the smaller 2BH1023 or 2BH1015 in the G-BH1 series?

Choose the 2BH1430 when your duty point requires up to 190 mbar vacuum or 170 mbar pressure at 60 Hz, or when the higher 1.6 kW power is needed for a given flow. The smaller siblings like 2BH1023 deliver lower maximum pressure and are better suited for lower-demand applications, saving space and energy.

What are the requirements for connecting this blower to a VFD or power supply?

The motor can be connected to a 3-phase supply with ±10% voltage tolerance and ±2% frequency tolerance. For converter operation, input voltage must not exceed 500 V with standard insulation. Use a motor overload relay set to 5.5 A (60 Hz) or 5.6 A (50 Hz). Ensure the supply can handle the starting current, which may be several times the rated current.

What are the ambient temperature and duty-cycle limits for continuous operation?

The blower is rated for continuous operation over the entire performance curve, but the maximum differential pressure is valid only when suction and ambient temperatures are up to 25 °C. Above this, derate the pressure or reduce the duty cycle to avoid motor overheating. The IP55 rating allows dusty or humid environments, but cooling air must be clean.

What maintenance items and accessories are not included in the base delivery?

The base delivery includes the blower only. You must provide motor protection (contactor/overload), electrical cables, and mating flanges for suction and discharge ports. No spare parts, filters, or silencers are included. Periodic maintenance includes bearing inspection every 10,000 hours and seal replacement if performance degrades.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1430 IE3 vacuum pump (EN)
Datasheet ·342,7 КБ ·2 pp.
View PDF