Elmo Rietschle 2BH1640
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1640

Elmo Rietschle 2BH1640 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270…300 mbar, Motor power 4.6 kW, Noise level 87 dB.

The 2BH1640 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH1 series, built with an IE3 premium-efficiency 3-phase motor rated 7.3 kW at 50 Hz and 9.9 kW at 60 Hz, protected to IP55 with class F insulation. It delivers a maximum vacuum of -210 mbar at 50 Hz (-270 mbar at 60 Hz) and a maximum positive pressure of 200 mbar at 50 Hz (300 mbar at 60 Hz), making it the largest frame in the G-BH1 range shown here. Its primary role is to provide oil-free, contactless vacuum or pressure for pneumatic conveying, drying, and aeration duties where moderate differential pressures and continuous duty are required.

Max. differential pressure
-270…300 mbar
Motor power
4.6 kW
Noise level
87 dB
Weight
87 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1640 Current 4.66565-240–26017.1IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -180 / 160 mbar (50 Hz, size 1)
50 Hz, size 2: -240 / 260 mbar · 50 Hz, size 3: -240 / 320 mbar · 60 Hz, size 1: -130 / 120 mbar · 60 Hz, size 2: -210 / 200 mbar · 60 Hz, size 3: -270 / 300 mbar
Motor power 4.6 kW (50 Hz, 190-210 V D, size 1)
60 Hz, 200 V, size 1: 5.3 kW · 50 Hz, 190-210 V D, size 2: 6.3 kW · 60 Hz, size 2: 7.3 kW · 50 Hz, 190-210 V D, size 3: 8.6 kW · 60 Hz, size 3: 9.9 kW
Noise level 65 dB(A) (size 1)
size 2: 75 dB(A) · size 3: 87 dB(A)
Max. differential pressure vacuum mfr -240 mbar (50 Hz)
Max. differential pressure vacuum mfr -270 mbar (60 Hz)
Order No. mfr 2BH1640-1GQ47
Series mfr 2BH1 640
Product type mfr Side channel blower with IE3-motors
Motor protection category mfr IP55
Approvals mfr UL and CSA approved
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Order No. mfr 2BH1640-1GK56 (50 Hz)
Order No. mfr 2BH1640-1GK56 (60 Hz)
Max. differential pressure vacuum mfr -210 mbar (60 Hz NEMA)
Dimensions, Weight & Mechanical Design
Weight 65 kg (size 1)
size 2: 75 kg · size 3: 87 kg
Weight approx. mfr 75 kg
Weight approx. mfr 87 kg (50 Hz)
Weight approx. mfr 87 kg (60 Hz)
Electrical, Power & Drive Specifications
Current 17.1 A (50 Hz, 190-210 V D, size 1)
60 Hz, 200 V, size 1: 19.6 A · 50 Hz, 190-210 V D, size 2: 23.5 A · 60 Hz, 190-210 V / 380-420 V, size 2: 27.6 A · 50 Hz, 190-210 V D, size 3: 30.8 A · 60 Hz, 190-210 V / 380-420 V, size 3: 35.2 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 D V (50 Hz)
60 Hz: 200 UU V
Rated frequency mfr 60 Hz (60 Hz)
Efficiency class mfr IE3
Rated voltage mfr 220-240 / 380-420 V (50 Hz)
Rated current mfr 26.8 / 15.5 A (50 Hz)
Rated power mfr 8.6 kW (50 Hz)
Efficiency class mfr IE3 (50 Hz)
Rated voltage mfr 220-240 / 440-480 V (60 Hz)
Rated current mfr 30.6 / 15.3 A (60 Hz)
Rated power mfr 9.9 kW (60 Hz)
Efficiency class mfr IE3 (60 Hz)
Rated voltage mfr 230 / 460 V (60 Hz NEMA)
Rated current mfr 24.0 / 12.0 A (60 Hz NEMA)
Rated power mfr 7.3 kW (60 Hz NEMA)
Efficiency class mfr NP (60 Hz NEMA)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 71 dB(A)
Sound pressure level mfr 71 dB(A) (50 Hz)
Sound pressure level mfr 75 dB(A) (60 Hz)
Sound pressure level mfr 75 dB(A) (60 Hz NEMA)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Process Limits
Do not exceed -210 mbar vacuum or +200 mbar pressure at 50 Hz

The maximum differential pressures are -210 mbar (vacuum) and +200 mbar (pressure) at 50 Hz, rising to -270 mbar and +300 mbar at 60 Hz. Operating beyond these limits increases internal leakage and motor load, and can cause overheating or mechanical damage. Size the process restriction so the blower cannot run against a closed or over-restricted line.

Technical Data Sheet — 2BH1640 IE3 vacuum pump (EN), performance data

Selection & Integration Q&A

When should I choose the 2BH1640 instead of the smaller G-BH1 siblings such as 2BH1023?

Pick the 2BH1640 when your duty needs up to -210 mbar vacuum or +200 mbar pressure at 50 Hz (or -270/+300 mbar at 60 Hz) and the resulting flow exceeds the smaller frames. The 2BH1023 and other siblings are more compact and lower-power; use them only if their pressure/flow curves cover the duty, since the 2BH1640's 7.3–9.9 kW motor and 75 kg mass are significantly larger.

What supply and starter arrangement does the 2BH1640 require?

It is a 3-phase IE3 motor wound for 380–420 V/50 Hz or 200 V/60 Hz, drawing 27.6 A or 35.2 A respectively. Provide a starter or DOL contactor with overload protection set to the nameplate current for the actual frequency; no VFD or soft starter is included, and the supply voltage must match the selected variant exactly.

What maintenance and accessories are needed beyond the base blower?

The base delivery is the blower only: no cables, starter, inlet filter or spare parts are included. Because the side-channel principle is oil-free and contactless, service focuses on bearing condition, cooling-air path and any separately supplied inlet filter. Order the mating electrical accessories and filter for your process, and set an inspection interval according to site dust loading.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1640 IE3 vacuum pump (EN)
Datasheet ·713,3 КБ ·2 pp.
View PDF