Elmo Rietschle 2BH1830 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 5.1 kW, Noise level 75 dB.

The 2BH1830 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH1 series, built as a size-2 machine with an IE3 premium-efficiency motor and IP55 protection. It delivers up to ±200 mbar differential at 50 Hz (−200 mbar vacuum / +200 mbar pressure at 50 Hz; −160 mbar vacuum / +130 mbar pressure at 60 Hz) from a 5.1 kW (50 Hz) / 5.8 kW (60 Hz) drive, making it the higher-capacity choice among the 2BH10xx siblings. It is intended for continuous vacuum or pressure duty in pneumatic conveying, aeration, or extraction circuits where a compact, oil-free ring blower is required.

Max. differential pressure
-160 mbar
Motor power
5.1 kW
Noise level
75 dB
Weight
133 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1830 Current 5.875133-16019.4IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -200 mbar (50 Hz)
60 Hz: -160 mbar
Motor power 5.1 kW (50 Hz)
60 Hz: 5.8 kW
Noise level 71 dB(A) (50 Hz)
60 Hz: 75 dB(A)
Max. differential pressure vacuum mfr -160 mbar (60 Hz)
Approval mfr UL 1450, CAN/CSA C22.2 No. 68-09 (E225239)
Dimensions, Weight & Mechanical Design
Weight 133 kg
Weight approx. mfr 130 kg
Electrical, Power & Drive Specifications
Current 19.4 A (50 Hz)
60 Hz: 22.0 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-480 V
Efficiency class mfr IE3
Voltage tolerance mfr ±10 %
Frequency tolerance mfr ±2 %
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AK11)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AK21)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AK16)
Rated voltage mfr 220-240 Δ / 380-420 Y V (50 Hz, 2BH1830-2AK16)
Rated voltage mfr 220-240 YY / 440-480 Y V (60 Hz, 2BH1830-2AK16)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AK26)
Rated voltage mfr 220-240 Δ / 380-420 Y V (50 Hz, 2BH1830-2AK26)
Rated voltage mfr 220-240 YY / 440-480 Y V (60 Hz, 2BH1830-2AK26)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AQ13)
Rated voltage mfr 500 Y V (50 Hz, 2BH1830-2AQ13)
Rated voltage mfr 575 Y V (60 Hz, 2BH1830-2AQ13)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AQ23)
Rated voltage mfr 500 Y V (50 Hz, 2BH1830-2AQ23)
Rated voltage mfr 575 Y V (60 Hz, 2BH1830-2AQ23)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AQ17)
Rated voltage mfr 380-420 Δ / 660-725 Y V (50 Hz, 2BH1830-2AQ17)
Rated voltage mfr 440-480 Δ V (60 Hz, 2BH1830-2AQ17)
Efficiency class mfr IE3 (50 Hz, 2BH1830-2AQ27)
Rated voltage mfr 380-420 Δ / 660-725 Y V (50 Hz, 2BH1830-2AQ27)
Rated voltage mfr 440-480 Δ V (60 Hz, 2BH1830-2AQ27)
Current (alt 60 Hz) mfr 11.0 A (60 Hz)
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level mfr 71 dB(A)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AK11)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AK11)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AK21)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AK21)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AK16)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AK16)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AK26)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AK26)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AQ13)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AQ13)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AQ23)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AQ23)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AQ17)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AQ17)
Sound pressure level mfr 71 dB(A) (50 Hz, 2BH1830-2AQ27)
Sound pressure level mfr 75 dB(A) (60 Hz, 2BH1830-2AQ27)

Description

Construction and series positioning

Performance behaviour

Installation and operation

Integration & Operating Notes

Electrical
Supply tolerance is only ±10 % voltage and ±2 % frequency

Operation outside these tolerances will shift the motor's operating point and can overheat the winding or reduce available differential pressure. Sites with weak grids or generator supply should be checked against these limits; a 60 Hz supply also lowers the maximum differential pressure to +130 / −160 mbar, so the process must be sized for the actual frequency.

Technical Data Sheet — 2BH1830 HT vacuum pump (EN), electrical data

Selection & Integration Q&A

When should I choose the 2BH1830 rather than a smaller 2BH10xx sibling?

Pick the 2BH1830 when the duty point needs up to ±200 mbar differential at 50 Hz and the flow that a size-2 impeller provides. The 2BH1009/1014/1015/1023 siblings are smaller frames with lower capacity; they suit lower-pressure or lower-flow duties where the 1830 would be oversized and draw unnecessary power.

What supply and protection must the panel provide for this blower?

A three-phase supply within ±10 % voltage and ±2 % frequency, linked for the site voltage (e.g. 380–420 V star at 50 Hz), with a motor protection device set to 18.7 A Δ / 9.7 A Y at 50 Hz. No starter or VFD is included, so start/stop and overload protection are panel-side responsibilities.

What is supplied with the blower and what must be ordered separately?

The base delivery is the blower with IE3 motor only; process connections, silencers, filters, relief valves, flexible connectors and electrical cables are not included. Confirm the exact order code (e.g. 2BH1830-2AK11 vs -2AQ13) because it encodes voltage and configuration variants that affect the ancillaries required.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1830 HT vacuum pump (EN)
Datasheet ·339,1 КБ ·2 pp.
View PDF