Elmo Rietschle 2BH1014
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1014

Elmo Rietschle 2BH1014 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -40 mbar, Motor power 0.25 kW, Noise level 61 dB.

The 2BH1014 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by a 1~ AC motor with permanently connected run capacitor. It delivers up to 55 mbar differential pressure in vacuum or compressor mode at 60 Hz, positioning it between the 2BH1009 and 2BH1015 siblings. Its compact 11 kg frame and IP55 protection suit continuous-duty industrial vacuum or pressure generation in clean, non-corrosive gas streams.

Max. differential pressure
-40 mbar
Motor power
0.25 kW
Noise level
61 dB
Weight
11 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1014 Current 0.325711-553.2–6.5IP55
2BH1009 ——————
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -40 mbar (50 Hz)
60 Hz: -55 mbar
Motor power 0.25 kW (50 Hz)
60 Hz: 0.32 kW
Noise level 57 dB (50 Hz)
60 Hz: 61 dB
Max. Differenzdruck Verdichter (alt 50 Hz) mfr 40 mbar (50 Hz)
Max. Differenzdruck Verdichter (alt 60 Hz) mfr 55 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 11 kg (50 Hz)
60 Hz: 11 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 6.5 / 3.2 A (50 Hz)
60 Hz: 5.9 / 3.0 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 1~ 50/60 Hz, IP55, Isolierstoffklasse F, Motor mit UL, mit angebautem Dauerbetriebskondensator
Voltage 115 / 230 V (50 Hz)
60 Hz: 115 / 230 V
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC

Description

Construction and series positioning

Performance and operating behavior

Electrical and control specifics

Installation and operation

Integration & Operating Notes

Electrical
Supply voltage must stay within ±5% of nominal

Exceeding the ±5% voltage tolerance can cause motor overheating, reduced torque, or capacitor failure. Verify the actual supply voltage under load, especially on long cable runs or shared circuits, and use a voltage stabilizer if fluctuations are common.

Technical Data Sheet — G-BH1 2BH1014 compressor (EN), Electrical Data
Electrical
Frequency tolerance is limited to ±2%

Operating the blower outside the ±2% frequency band (e.g., on 50 Hz supply when 60 Hz is specified) will shift speed and thus pressure/flow performance, and may overload the motor. Ensure the supply frequency matches the order variant (V4 for 50 Hz, V5 for 60 Hz).

Technical Data Sheet — G-BH1 2BH1014 compressor (EN), Electrical Data
Control & I/O
Run capacitor is factory-installed and must remain connected

The permanently connected run capacitor is part of the motor circuit; removing or disconnecting it will prevent the motor from starting or cause overheating. Do not substitute with a different capacitance value; use only original spare parts.

Technical Data Sheet — G-BH1 2BH1014 compressor (EN), Motor Type
Process Limits
Maximum differential pressure must not be exceeded

The blower is rated for a maximum differential pressure of 40 mbar at 50 Hz and 55 mbar at 60 Hz in both vacuum and compressor modes. Exceeding this limit can cause motor overload, overheating, or mechanical damage. Install a pressure relief valve or monitor differential pressure in the system.

Technical Data Sheet — G-BH1 2BH1014 compressor (EN), Performance Data
Mounting
IP55 protection permits dusty or damp indoor environments

The IP55 rating protects against dust ingress and water jets, making the blower suitable for many industrial indoor settings. However, it is not intended for outdoor use or immersion. Ensure the mounting location allows free air circulation around the motor for cooling.

Technical Data Sheet — G-BH1 2BH1014 compressor (EN), Motor Type

Selection & Integration Q&A

When should I choose the 2BH1014 over the 2BH1009 or 2BH1015?

Choose the 2BH1014 when you need up to 55 mbar differential pressure at 60 Hz in a single-phase, 11 kg package. The 2BH1009 offers lower capacity; the 2BH1015 provides higher capacity but may be physically larger. Select based on required pressure/flow and available mounting space.

What are the power supply requirements for the 2BH1014?

The 2BH1014 requires a 1~ AC supply of 115/230 V (V5 variant) or 100/200 V (V4 variant) at 50 or 60 Hz, with voltage tolerance ±5% and frequency tolerance ±2%. The motor includes a permanently connected run capacitor; no external starter is needed.

Can the 2BH1014 be installed outdoors or in a wet environment?

The motor is rated IP55, which protects against dust and water jets, but the blower is not designed for outdoor installation without additional enclosure. Avoid direct exposure to rain or standing water; ensure adequate ventilation and ambient temperature within motor limits.

What maintenance does the 2BH1014 require and what accessories are needed?

No specific maintenance schedule is provided in the available digest; refer to the instruction manual for bearing inspection and filter cleaning intervals. Base delivery does not include inlet filters, silencers, or flexible connectors; these must be ordered separately as required for the application.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH1 2BH1014 compressor (EN)
Datasheet ·194,0 КБ ·2 pp.
View PDF