Elmo Rietschle 2BH1600
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1600

Elmo Rietschle 2BH1600 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 330 mbar, Motor power 1.75 kW, Noise level 64 dB.

The 2BH1600 is a side-channel blower from the Elmo Rietschle G-BH1 series, driven by a 1.75 kW (50 Hz) / 2.00 kW (60 Hz) IE3 motor with IP55 protection. It delivers a maximum differential pressure of 120 mbar in pressure mode and -130 mbar in vacuum mode at 50 Hz, with a sound pressure level of 63 dB(A). This model is positioned as a mid-range unit in the series, suitable for continuous duty in pneumatic conveying, vacuum lifting, or aeration processes where moderate pressure and vacuum are required.

Max. differential pressure
330 mbar
Motor power
1.75 kW
Noise level
64 dB
Weight
55 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1600 Current 1.7572311309.9IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 130 mbar (50 Hz, size 1)
60 Hz, size 1: 110 mbar · 50 Hz, size 2: 200 mbar · 60 Hz, size 2: 190 mbar · 50 Hz, size 3: 280 mbar · 60 Hz, size 3: 270 mbar · 50 Hz, size 4: 290 mbar · 60 Hz, size 4: 330 mbar
Motor power 1.75 kW (50 Hz, size 1)
60 Hz, size 1: 2.00 kW · 50 Hz, size 2: 2.50 kW · 60 Hz, size 2: 3.00 kW · 50 Hz, size 3: 3.45 kW · 60 Hz, size 3: 4.0 kW · 50 Hz, size 4: 4.6 kW · 60 Hz, size 4: 5.3 kW
Noise level 69 dB(A) (50 Hz, size 1)
60 Hz, size 1: 72 dB(A) · 50 Hz, size 2: 64 dB(A) · 60 Hz, size 2: 70 dB(A) · 50 Hz, size 3: 71 dB(A) · 60 Hz, size 3: 74 dB(A) · 50 Hz, size 4: 69 dB(A) · 60 Hz, size 4: 71 dB(A)
Max. differential pressure vacuum mfr -130 mbar (50 Hz)
Max. differential pressure vacuum mfr -110 mbar (60 Hz)
Product type mfr Side channel blower with IE3-motors
Vacuum mfr -130 mbar (50 Hz)
Vacuum mfr -110 mbar (60 Hz)
Order No. mfr 2BH1600-0AK01
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Dimensions, Weight & Mechanical Design
Weight 31 kg (size 1)
size 2: 34 kg · size 3: 38 kg · size 4: 55 kg
Electrical, Power & Drive Specifications
Current 6.9 A (50 Hz, delta, size 1)
60 Hz, size 1: 7.8 YY / 3.9 Y A · 60 Hz, NEMA, size 1: 7.8 A · 50 Hz, delta, size 2: 9.9 A · 60 Hz, size 2: 12.0 YY / 6.0 Y A · 60 Hz, NEMA, size 2: 12.0 YY A · 50 Hz, delta, size 3: 13.3 A · 60 Hz, size 3: 15.2 YY / 7.6 Y A · 60 Hz, NEMA, size 3: 15.2 YY A · 50 Hz, delta/YY, size 4: 17.1 / 9.9 A · 60 Hz, size 4: 19.6 YY / 9.8 Y A · 60 Hz, NEMA, size 4: 19.6 YY A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz, delta, size 1)
60 Hz, size 1: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 1: 200 V · 50 Hz, delta, size 2: 190-210 V · 60 Hz, size 2: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 2: 200 YY V · 50 Hz, delta, size 3: 190-210 V · 60 Hz, size 3: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 3: 200 YY V · 50 Hz, delta/YY, size 4: 190-210 / 380-420 V · 60 Hz, size 4: 190-210 YY / 380-420 Y V · 60 Hz, NEMA, size 4: 200 YY V
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Rated current mfr 7.8 A (60 Hz)
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC (max)
Sound pressure level mfr 69 dB(A) (50 Hz)
Sound pressure level mfr 72 dB(A) (60 Hz)

Description

Construction and positioning

Performance behavior

Installation and operation

Integration & Operating Notes

Electrical
Dual voltage configuration requires correct terminal linking

The motor is designed for 220-240 V delta or 380-420 V star at 50 Hz, and 440-480 V star at 60 Hz. Incorrect terminal linking will cause motor failure. Verify the supply voltage and frequency before connecting, and ensure the terminal box links match the nameplate diagram. Use a motor protection switch set to the rated current for the selected connection: at 50 Hz, 6.9 A (delta, size 1); at 60 Hz, 7.8 A (NEMA, size 1) or 7.8 YY / 3.9 Y A (size 1).

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 2BH1600 over the smaller 2BH1014 or 2BH1015 models in the G-BH1 series?

Choose the 2BH1600 when your process requires higher pressure (up to 130 mbar at 50 Hz, size 1) than the smaller models can provide. The 2BH1600 also offers a higher power rating (1.75 kW at 50 Hz, size 1) for increased flow capacity. If your duty point is well within the capabilities of the 2BH1014 or 2BH1015, those may be more energy-efficient and cost-effective.

What are the requirements for the electrical supply and protection when integrating the 2BH1600?

The motor requires a three-phase supply matching the nameplate voltage (e.g., 400 V star at 50 Hz). Use a motor protection switch set to the rated current for the selected connection: at 50 Hz, 6.9 A (delta, size 1); at 60 Hz, 7.8 A (NEMA, size 1) or 7.8 YY / 3.9 Y A (size 1). The motor has PTC thermistors that must be connected to a tripping unit or control system to prevent overheating. Ensure the supply can handle the starting current, which may be 6-8 times the rated current.

What are the ambient temperature and duty cycle limitations for the 2BH1600?

The standard motor is designed for ambient temperatures up to 40°C. For higher temperatures, derating may be required. The blower is suitable for continuous duty (S1), but the actual operating point should be within the specified pressure limits. Ensure adequate ventilation to prevent overheating, especially when installed in enclosures.

What maintenance items and accessories are not included with the base blower, and what should be ordered separately?

The base delivery includes the blower only. Flexible connectors, inlet/outlet silencers, filters, and a motor protection switch are not included and must be ordered separately. For maintenance, keep spare impeller, bearings, and gaskets on hand. Refer to the spare parts list in the manual for part numbers.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1600 IE3 vacuum pump (EN)
Datasheet ·443,3 КБ ·2 pp.
View PDF