Elmo Rietschle 2BH1590 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -220 mbar, Motor power 1.3 kW, Noise level 61 dB.
The 2BH1590 is a side-channel (regenerative) blower from the Elmo Rietschle G-BH1 series, built as a 2BH1400-1AQ27 with a 1.60 kW IE3 three-phase motor, IP55 protection and class F insulation. It delivers up to 210 mbar gauge in compressor mode and -220 mbar in vacuum mode, with a 64 dB(A) sound pressure level and 21 kg approximate weight. This modification is intended for continuous-duty air movement in pneumatic conveying, vacuum holding and low-pressure compression circuits where oil-free operation and compact footprint are required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1590 Current | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -190 mbar (50 Hz) 60 Hz: -220 mbar |
| Motor power | 1.30 kW (50 Hz) 60 Hz: 1.60 kW |
| Noise level | 61 dB (50 Hz) 60 Hz: 64 dB |
| Typ-Nr. mfr | 2BH1400-1AQ27 |
| Frequenz mfr | 50 Hz (50 Hz) |
| Frequenz mfr | 60 Hz (60 Hz) |
| Max. Differenzdruck Vakuum mfr | -220 mbar |
| Max. Differenzdruck Verdichter mfr | 210 mbar |
| Effizienzklasse mfr | IE3 |
| Model designation mfr | 2BH1400 |
| Max. differential pressure vacuum mfr | -180 mbar (50 Hz, D) |
| Max. differential pressure compressor mfr | 170 mbar (50 Hz, D) |
| Max. differential pressure vacuum mfr | -170 mbar (60 Hz, IE3) |
| Max. differential pressure compressor mfr | 160 mbar (60 Hz, IE3) |
| Max. differential pressure vacuum mfr | -170 mbar (60 Hz, NP) |
| Max. differential pressure compressor mfr | 160 mbar (60 Hz, NP) |
| Order number mfr | 2BH1400-1AK11 |
| Max. Differenzdruck Verdichter (alt 50 Hz) mfr | 220 mbar (50 Hz) |
| Max. Differenzdruck Verdichter (alt 60 Hz) mfr | 210 mbar (60 Hz) |
| Frequenz (alt var) mfr | 60 Hz |
| Weight | 21 kg |
| Current | 4.9 A (50 Hz, 220-240 D) 50 Hz, 380-420 U: 2.85 A · 60 Hz, 220-240 UU: 5.5 A · 60 Hz, 440-480 U: 2.75 A · 60 Hz, 230 UU: 5.5 A · 60 Hz, 460 U: 2.75 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 220-240 D V (50 Hz) 60 Hz: 220-240 UU V |
| Spannungsbereich mfr | 380-420 D / 660-725 U V (50 Hz) |
| Spannungsbereich mfr | 460 D V (60 Hz) |
| Strom mfr | 2,75 A (50 Hz) |
| Strom mfr | 2,75 A (60 Hz) |
| Strom mfr | 2,75 A (60 Hz (460 V)) |
| Leistung mfr | 1,60 kW (50 Hz) |
| Leistung mfr | 1,60 kW (60 Hz) |
| Leistung mfr | 1,60 kW (60 Hz (460 V)) |
| Efficiency class mfr | IE3 |
| Rated voltage mfr | 190-210 V (50 Hz, D) |
| Rated voltage mfr | 190-210 UU / 380-420 U V (60 Hz, IE3) |
| Rated voltage mfr | 200 UU V (60 Hz, NP) |
| voltage (alt 50 Hz) mfr | 380-420 U V (50 Hz) |
| voltage (alt 60 Hz) mfr | 460 U V (60 Hz) |
| Protection rating | IP55 |
| Schalldruckpegel mfr | 64 dB(A) |
| Sound pressure level mfr | 61 dB(A) (50 Hz, D) |
| Sound pressure level mfr | 64 dB(A) (60 Hz, IE3) |
| Sound pressure level mfr | 64 dB(A) (60 Hz, NP) |
Description
Construction and series positioning
- The 2BH1590 is a single-stage side-channel blower with an impeller running in a toroidal channel; the motor is integrated on a common shaft with the impeller, eliminating belts or couplings.
- Within the G-BH1 series, the 2BH1590 (2BH1400-1AQ27) is the larger frame size relative to the 2BH1009, 2BH1014, 2BH1015 and 2BH1023 siblings, offering higher pressure capability and motor power for the same 50/60 Hz supply.
- The IE3 efficiency class and IP55 enclosure make it suitable for dusty or damp industrial environments where standard IP54 or lower-efficiency motors would be derated.
Behavior under load and media
- Maximum differential pressure is 210 mbar in compressor mode and -220 mbar in vacuum mode; these are the upper limits for continuous operation and should not be exceeded even briefly.
- The 1.60 kW motor draws 2.75 A at both 50 Hz (380–420 V delta / 660–725 V star) and 60 Hz (460 V delta), giving a consistent current draw across frequencies but requiring correct winding connection for the available mains.
- The 64 dB(A) sound pressure level is measured at typical operating conditions; in enclosed cabinets or near-sensitive equipment, additional acoustic attenuation may be needed.
- No digitized curve points are available for this model, so the pressure-flow characteristic must be obtained from the manufacturer's published curve for the 2BH1400-1AQ27 at the actual operating speed.
Installation, connection and control
- The motor is a three-phase induction machine with voltage ranges 380–420 V delta / 660–725 V star at 50 Hz and 460 V delta at 60 Hz; the terminal box must be wired according to the nameplate and the supply frequency.
- IP55 protection allows installation in areas subject to water jets and dust, but the blower should be mounted with the motor axis horizontal and with sufficient clearance for cooling air intake and exhaust.
- The datasheet references UL 1450 and CAN/CSA 22.2 No 68-09 (certificate E225239), indicating compliance with North American safety standards for compressors and vacuum pumps.
- No specific control interface is described in the digest; the blower is a direct-on-line or starter-driven motor without integrated VFD, so external overload protection and contactors must be sized per the 2.75 A full-load current.
Integration & Operating Notes
The IP55 motor relies on surface cooling; mounting in a confined space or with restricted airflow will raise winding temperature and may shorten insulation life. Maintain at least the clearance recommended in the installation instructions and avoid recirculating hot exhaust air into the intake.
Dust and debris accumulating in the side channel reduce performance and can cause imbalance. The service interval depends on the process air cleanliness; in dusty environments, monthly inspection is advised. No lubrication is required for the blower bearings (sealed-for-life), but motor bearings should be checked per the manual's schedule.
Selection & Integration Q&A
Choose the 2BH1590 when your process needs up to 210 mbar compression or -220 mbar vacuum and the 1.60 kW motor is sufficient. The smaller 2BH1023 delivers lower pressure and flow; if your duty point falls within its curve, it saves space and weight. Select the 2BH1590 when higher differential pressure is the primary requirement and the 21 kg weight is acceptable.
Provide a three-phase supply matching the nameplate: 380–420 V delta or 660–725 V star at 50 Hz, or 460 V delta at 60 Hz. Use a motor starter with overload protection set to 2.75 A. The IP55 enclosure does not include a built-in disconnect; install a lockable isolator within sight of the blower.
IP55 protects against dust and water jets, so wash-down is permissible, but the blower is not designed for outdoor installation without a protective cover. Avoid direct rain and ensure the motor cooling air is clean. Ambient temperature limits are not stated in the digest; consult the manual for derating above 40 °C.
The base delivery includes the blower only. You must separately order: flexible connectors to isolate vibration, inlet/outlet silencers if lower noise is needed, a suction filter for dusty air, and a motor protection switch or contactor. Spare impellers and gaskets are available as service parts; no lubrication is supplied because bearings are sealed-for-life.