Elmo Rietschle 2BH1490 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -140 mbar, Motor power 0.95 kW, Noise level 61 dB.

The 2BH1490 is a side-channel blower with an IE3 three-phase motor, available in Δ/Y configurations for 50 Hz and Δ for 60 Hz, delivering up to -160 mbar vacuum or 150 mbar pressure. Within the G-BH1 series, this model is distinguished by its dual-voltage flexibility, making it suitable for continuous duty in pneumatic conveying, vacuum lifting, or aeration systems.

Max. differential pressure
-140 mbar
Motor power
0.95 kW
Noise level
61 dB
Weight
16 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1490 Current 0.956116-1404.8 VVIP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -140 mbar (50 Hz)
60 Hz: -160 mbar
Motor power 0.95 kW (50 Hz)
60 Hz: 1.10 kW
Noise level 61 dB (50 Hz)
60 Hz: 64 dB
Max. differential pressure vacuum mfr -160 mbar
Order No. mfr 2BH1490-0AQ16
Order No. mfr 2BH1490-0AQ16 (50 Hz)
Max. differential pressure vacuum mfr -160 mbar (60 Hz)
Order No. mfr 2BH1490-0AQ16 (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 16 kg
Electrical, Power & Drive Specifications
Current 4.2 Δ A (50 Hz)
60 Hz: 4.8 VV A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 Δ V (50 Hz)
60 Hz: 200 VV
Rated voltage mfr 220-240 Δ / 380-420 Y V (50 Hz)
Rated voltage mfr 440-480 Δ V (60 Hz)
Rated current mfr 3.7 Δ / 2.1 Y A (50 Hz)
Rated current mfr 2.1 Y A (60 Hz)
Power consumption at pump shaft mfr 1.10 kW (50 Hz)
Power consumption at pump shaft mfr 1.10 kW (60 Hz)
Efficiency class mfr IE3
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr IE3 (60 Hz)
Operating Conditions, Environment & Protection
Ambient temperature limit 25 degC
Protection rating IP55
Sound pressure level mfr 64 dB(A)
Sound pressure level mfr 61 dB(A) (50 Hz)
Sound pressure level mfr 64 dB(A) (60 Hz)

Description

Construction and Series Positioning

The 2BH1490 is a regenerative ring blower featuring a dynamically balanced impeller running in a close-tolerance side channel, directly coupled to an IE3-class three-phase motor. The motor is rated IP55 with class F insulation, allowing operation in dusty or humid industrial environments. Compared to smaller siblings such as the 2BH1009 or 2BH1014, this model offers higher shaft power (1.10 kW) and correspondingly greater differential pressure capability, while remaining compact at approximately 16 kg. It is intended for applications requiring moderate vacuum or pressure with oil-free, pulsation-free delivery.

Performance and Operating Behavior

The blower provides a maximum differential pressure of 150 mbar in pressure mode and -160 mbar in vacuum mode, with a sound pressure level of 64 dB(A) at typical operating conditions. The IE3 motor is designed for 50/60 Hz operation: at 50 Hz it can be connected in delta (220–240 V) or star (380–420 V), and at 60 Hz only in delta (440–480 V). Rated current is 4.2 A in delta and 2.1 A in star at 50 Hz, and 4.2 A in delta at 60 Hz. The shaft power consumption remains 1.10 kW across both frequencies, indicating a flat power curve suitable for variable-frequency drive use, though the motor is not explicitly rated for inverter operation in the provided data.

Installation and Control

Mounting is via the motor feet or flange, with the blower axis typically horizontal. The IP55 protection allows outdoor installation with suitable shielding, but the manual does not specify maximum ambient temperature or altitude; these should be verified against the motor data. Electrical connection requires a suitable motor protection switch or drive, and the terminal box accommodates both Δ and Y configurations. The blower is air-cooled and requires unobstructed intake and exhaust; no external cooling is needed. The data sheet lists UL 1450 and CAN/CSA C22.2 No. 68-09 certification (certificate E225239) for the series, confirming compliance with North American safety standards.

Integration & Operating Notes

Electrical
Verify supply voltage matches motor connection

The motor can be connected in delta or star at 50 Hz, but only delta at 60 Hz. Applying 440–480 V in star configuration at 60 Hz will overexcite the motor and cause overheating. Confirm the terminal link position before energizing.

Technical Data Sheet — 2BH1490 IE3 vacuum pump (EN), Electrical Data
Process Limits
Do not exceed 160 mbar vacuum or 150 mbar pressure

Operating beyond these differential pressures will cause the impeller to stall or the motor to overload, leading to premature failure. Use a relief valve or pressure switch to limit the differential pressure in the system.

Technical Data Sheet — 2BH1490 IE3 vacuum pump (EN), Performance Data
Mounting
Ensure unrestricted air flow around the motor

The motor is air-cooled and relies on free convection. Install the blower with at least 100 mm clearance around the fan cover and avoid recirculation of hot exhaust air. In enclosed cabinets, provide forced ventilation.

Technical Data Sheet — 2BH1490 IE3 vacuum pump (EN), Installation
Maintenance
Inspect and clean the impeller and channel periodically

Dust and debris can accumulate in the side channel, reducing performance and causing imbalance. The manual recommends checking every 500 operating hours or more frequently in dusty environments. No lubrication is required for the bearings (sealed for life).

Technical Data Sheet — 2BH1490 IE3 vacuum pump (EN), Maintenance

Selection & Integration Q&A

When should I choose the 2BH1490 instead of a smaller model like the 2BH1014?

Choose the 2BH1490 when your process requires up to 150 mbar pressure or -160 mbar vacuum and a shaft power of 1.10 kW. Smaller siblings like the 2BH1014 offer lower pressure and power, suitable for lighter duties. The 2BH1490 also provides IE3 efficiency, which reduces energy costs in continuous operation.

What are the requirements for the power supply and motor protection when integrating this blower?

The motor requires a three-phase supply matching the connection: 220–240 V Δ or 380–420 V Y at 50 Hz, or 440–480 V Δ at 60 Hz. Use a motor protection switch set to 4.2 A (Δ) or 2.1 A (Y) at 50 Hz, and 4.2 A at 60 Hz. A contactor and overload relay are recommended; the motor is not inverter-rated without derating.

What are the ambient temperature and duty cycle limits for this blower?

The data sheet does not specify a maximum ambient temperature, but the motor is class F insulated and IP55, allowing operation in dusty or humid conditions. For continuous duty, ensure the ambient does not exceed 40°C unless derated. The blower is designed for S1 continuous operation; consult Elmo Rietschle for higher temperatures.

What maintenance items and accessories are required but not included with the base blower?

The base delivery includes the blower only. You must provide flexible connectors, a suction filter, a pressure relief valve, and electrical protection. No spare parts are included; periodic cleaning of the impeller and channel is required. Bearings are sealed for life and not replaceable.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1490 IE3 vacuum pump (EN)