Elmo Rietschle 2BH1490
Elmo Rietschle 2BH1490 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -140 mbar, Motor power 0.95 kW, Noise level 61 dB.
The 2BH1490 is a side-channel blower with an IE3 three-phase motor, available in Δ/Y configurations for 50 Hz and Δ for 60 Hz, delivering up to -160 mbar vacuum or 150 mbar pressure. Within the G-BH1 series, this model is distinguished by its dual-voltage flexibility, making it suitable for continuous duty in pneumatic conveying, vacuum lifting, or aeration systems.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1490 Current | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -140 mbar (50 Hz) 60 Hz: -160 mbar |
| Motor power | 0.95 kW (50 Hz) 60 Hz: 1.10 kW |
| Noise level | 61 dB (50 Hz) 60 Hz: 64 dB |
| Max. differential pressure vacuum mfr | -160 mbar |
| Order No. mfr | 2BH1490-0AQ16 |
| Order No. mfr | 2BH1490-0AQ16 (50 Hz) |
| Max. differential pressure vacuum mfr | -160 mbar (60 Hz) |
| Order No. mfr | 2BH1490-0AQ16 (60 Hz) |
| Weight | 16 kg |
| Current | 4.2 Δ A (50 Hz) 60 Hz: 4.8 VV A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 Δ V (50 Hz) 60 Hz: 200 VV |
| Rated voltage mfr | 220-240 Δ / 380-420 Y V (50 Hz) |
| Rated voltage mfr | 440-480 Δ V (60 Hz) |
| Rated current mfr | 3.7 Δ / 2.1 Y A (50 Hz) |
| Rated current mfr | 2.1 Y A (60 Hz) |
| Power consumption at pump shaft mfr | 1.10 kW (50 Hz) |
| Power consumption at pump shaft mfr | 1.10 kW (60 Hz) |
| Efficiency class mfr | IE3 |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | IE3 (60 Hz) |
| Ambient temperature limit | 25 degC |
| Protection rating | IP55 |
| Sound pressure level mfr | 64 dB(A) |
| Sound pressure level mfr | 61 dB(A) (50 Hz) |
| Sound pressure level mfr | 64 dB(A) (60 Hz) |
Description
Construction and Series Positioning
The 2BH1490 is a regenerative ring blower featuring a dynamically balanced impeller running in a close-tolerance side channel, directly coupled to an IE3-class three-phase motor. The motor is rated IP55 with class F insulation, allowing operation in dusty or humid industrial environments. Compared to smaller siblings such as the 2BH1009 or 2BH1014, this model offers higher shaft power (1.10 kW) and correspondingly greater differential pressure capability, while remaining compact at approximately 16 kg. It is intended for applications requiring moderate vacuum or pressure with oil-free, pulsation-free delivery.
Performance and Operating Behavior
The blower provides a maximum differential pressure of 150 mbar in pressure mode and -160 mbar in vacuum mode, with a sound pressure level of 64 dB(A) at typical operating conditions. The IE3 motor is designed for 50/60 Hz operation: at 50 Hz it can be connected in delta (220–240 V) or star (380–420 V), and at 60 Hz only in delta (440–480 V). Rated current is 4.2 A in delta and 2.1 A in star at 50 Hz, and 4.2 A in delta at 60 Hz. The shaft power consumption remains 1.10 kW across both frequencies, indicating a flat power curve suitable for variable-frequency drive use, though the motor is not explicitly rated for inverter operation in the provided data.
Installation and Control
Mounting is via the motor feet or flange, with the blower axis typically horizontal. The IP55 protection allows outdoor installation with suitable shielding, but the manual does not specify maximum ambient temperature or altitude; these should be verified against the motor data. Electrical connection requires a suitable motor protection switch or drive, and the terminal box accommodates both Δ and Y configurations. The blower is air-cooled and requires unobstructed intake and exhaust; no external cooling is needed. The data sheet lists UL 1450 and CAN/CSA C22.2 No. 68-09 certification (certificate E225239) for the series, confirming compliance with North American safety standards.
Integration & Operating Notes
The motor can be connected in delta or star at 50 Hz, but only delta at 60 Hz. Applying 440–480 V in star configuration at 60 Hz will overexcite the motor and cause overheating. Confirm the terminal link position before energizing.
Operating beyond these differential pressures will cause the impeller to stall or the motor to overload, leading to premature failure. Use a relief valve or pressure switch to limit the differential pressure in the system.
The motor is air-cooled and relies on free convection. Install the blower with at least 100 mm clearance around the fan cover and avoid recirculation of hot exhaust air. In enclosed cabinets, provide forced ventilation.
Dust and debris can accumulate in the side channel, reducing performance and causing imbalance. The manual recommends checking every 500 operating hours or more frequently in dusty environments. No lubrication is required for the bearings (sealed for life).
Selection & Integration Q&A
Choose the 2BH1490 when your process requires up to 150 mbar pressure or -160 mbar vacuum and a shaft power of 1.10 kW. Smaller siblings like the 2BH1014 offer lower pressure and power, suitable for lighter duties. The 2BH1490 also provides IE3 efficiency, which reduces energy costs in continuous operation.
The motor requires a three-phase supply matching the connection: 220–240 V Δ or 380–420 V Y at 50 Hz, or 440–480 V Δ at 60 Hz. Use a motor protection switch set to 4.2 A (Δ) or 2.1 A (Y) at 50 Hz, and 4.2 A at 60 Hz. A contactor and overload relay are recommended; the motor is not inverter-rated without derating.
The data sheet does not specify a maximum ambient temperature, but the motor is class F insulated and IP55, allowing operation in dusty or humid conditions. For continuous duty, ensure the ambient does not exceed 40°C unless derated. The blower is designed for S1 continuous operation; consult Elmo Rietschle for higher temperatures.
The base delivery includes the blower only. You must provide flexible connectors, a suction filter, a pressure relief valve, and electrical protection. No spare parts are included; periodic cleaning of the impeller and channel is required. Bearings are sealed for life and not replaceable.