Elmo Rietschle 2BH1610
Elmo Rietschle 2BH1610 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 670 mbar, Motor power 2.5 kW, Noise level 69 dB.
Side-channel regenerative blower 2BH1 610 from the G-BH 1 N series, built as a single-stage (or multi-stage, per variant) contactless impeller unit driven by an IE3 three-phase motor in IP55 / class F. It is the largest frame in the 2BH10xx sibling group (1009, 1014, 1015, 1023), so it is selected when the smaller frames cannot reach the required pressure ratio at the duty point. Used as a vacuum or pressure source in pneumatic conveying, aeration and holding-air circuits.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1610 Current | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1830 | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | 160 mbar (50 Hz, size 1, IE3) 60 Hz, size 1, IE3: 120 mbar · 50 Hz, size 2, IE3: 260 mbar · 60 Hz, size 2, IE3: 200 mbar · 50 Hz, size 3, IE3: 360 mbar · 60 Hz, size 3, IE3: 320 mbar · 50 Hz, size 4, IE3: 530 mbar · 60 Hz, size 4, IE3: 490 mbar · 50 Hz, size 5, IE3: 610 mbar · 60 Hz, size 5, IE3: 670 mbar |
| Motor power | 2.50 kW (50 Hz, size 1, IE3) 60 Hz, size 1, IE3: 3.00 kW · 50 Hz, size 2, IE3: 3.45 kW · 60 Hz, size 2, IE3: 4.0 kW · 50 Hz, size 3, IE3: 4.6 kW · 60 Hz, size 3, IE3: 5.3 kW · 50 Hz, size 4, IE3: 6.3 kW · 60 Hz, size 4, IE3: 7.3 kW · 50 Hz, size 5, IE3: 8.6 kW · 60 Hz, size 5, IE3: 9.9 kW |
| Noise level | 69 dB (50 Hz, size 1, IE3) 60 Hz, size 1, IE3: 73 dB · 50 Hz, size 2, IE3: 75 dB · 60 Hz, size 2, IE3: 73 dB · 50 Hz, size 3, IE3: 67 dB · 60 Hz, size 3, IE3: 71 dB · 50 Hz, size 4, IE3: 71 dB · 60 Hz, size 4, IE3: 75 dB · 50 Hz, size 5, IE3: 71 dB · 60 Hz, size 5, IE3: 75 dB |
| Series mfr | G-BH 1 N |
| Model mfr | 2BH1 610 |
| Approval mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Reference atmospheric pressure mfr | 1013 mbar |
| Performance curve tolerance mfr | ± 10 % |
| Max. differential pressure vacuum mfr | -420 mbar (50 Hz) |
| Max. differential pressure vacuum mfr | -440 mbar (60 Hz) |
| Weight | 48 kg (size 1) size 2: 58 kg · size 3: 65 kg · size 4: 73 kg · size 5: 85 kg |
| Number of stages | UL 1450 and CAN/CSA C22.2 No. 68-09 (E225239) |
| Current | 6.0 A (50 Hz) 50 Hz 190-210 V: 2.50 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 / 380-420 V (50 Hz) 60 Hz: 200 V |
| Motor efficiency class mfr | IE3 |
| Voltage tolerance mfr | +/-10 % |
| Frequency tolerance mfr | +/- 2 % |
| Possible converter input voltage mfr | 500 V |
| Rated voltage mfr | 200 V (60 Hz) |
| Rated current mfr | 35.2 A (60 Hz) |
| Rated current mfr | 30.8 A (50 Hz) |
| Efficiency class mfr | IE3 (50 Hz) |
| Efficiency class mfr | NP (60 Hz) |
| Inlet connection | F |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level tolerance mfr | ±3 dB(A) |
| Sound pressure level mfr | 67 dB(A) (50 Hz) |
| Sound pressure level mfr | 71 dB(A) (60 Hz) |
| Measuring surface sound pressure level standard mfr | EN ISO 3744 |
Description
Construction and series position
- Regenerative (side-channel) blower with a non-contacting impeller; no internal lubrication in the gas path.
- IE3 three-phase motor, IP55 enclosure, insulation class F, UL 1450 / CAN/CSA C22.2 No. 68-09 (E225239).
- Within the G-BH 1 N family the 2BH1 610 is the top frame of the 2BH10xx group; siblings 2BH1009/1014/1015/1023 cover lower flow/pressure duties, so the 610 is chosen when the duty point sits outside their curves rather than as a first choice.
- Multiple performance stages (1–5) and a wide set of voltage/frequency windings (190–210/380–420 V up to 475–525/550–600 V, plus 220–240 V single-voltage and 440–480 V variants) are offered under the same model code; the exact type designation (e.g. -0HK11, -1HK51, -0HQ26) fixes stage count and winding.
Behavior under load and media
- Performance curves are published with a ±10 % tolerance; catalog values are not guaranteed point-by-point, so the duty point must be checked against the actual curve for the ordered stage/winding.
- Reference conditions for published data: 15 °C air, 1013 mbar atmospheric; sound pressure level to EN ISO 3744 with ±3 dB(A) tolerance.
- Maximum suction and ambient temperature is 25 °C for the stated total pressure differences; higher temperatures reduce achievable pressure ratio and must be re-rated.
- Voltage tolerance ±10 %, frequency tolerance ±2 % — operation outside these bands shifts speed and therefore flow/pressure.
Installation, connection and control
- Motor is designed for direct-on-line or converter operation; converter input voltage up to 500 V is permitted per the data sheet.
- IP55 allows dusty/wet industrial surroundings but not immersion; the motor cooling air path must remain unobstructed.
- No control electronics are integrated: start/stop, overload protection and any speed control are provided by the panel or VFD supplied by the integrator.
- The data sheet covers only performance and electrical data; piping, silencers and filters are system-side items.
Integration & Operating Notes
The 2BH1 610 is offered in many winding variants from 190–210/380–420 V up to 475–525/550–600 V plus 220–240 V single-voltage types. Supplying the wrong variant outside ±10 % voltage and ±2 % frequency tolerance shifts speed and invalidates the published curve.
Published pressure differences apply only up to 25 °C suction and ambient. Above this the achievable pressure ratio drops and motor thermal margin shrinks; re-rate against the curve or add cooling rather than relying on the nameplate figure.
The blower has no integrated control or protection. The panel must provide contactor/soft-start or VFD, overload relay set to motor FLA, and any pressure/flow interlocks; converter input voltage up to 500 V is allowed.
IP55 protects the motor from dust and water jets but not immersion. Mount so cooling air is not recirculated from the blower discharge and the intake is not obstructed; flexible connectors reduce vibration transmission to piping.
The data sheet gives no service interval; bearing lubrication/replacement and inlet filter cleaning follow the instruction manual. Because the impeller is non-contacting, wear is concentrated in bearings and filters, so schedule checks accordingly.
Selection & Integration Q&A
Pick the 610 only when the required flow at the target pressure difference falls outside the curves of the smaller 2BH10xx frames; it is the largest frame in that group, so oversizing wastes energy and adds noise. If a smaller sibling meets the duty point with margin, use it.
Three-phase supply within ±10 % voltage and ±2 % frequency of the ordered winding; IE3 motor, IP55, class F. Converter operation is permitted with converter input voltage up to 500 V. Provide external overload protection and a contactor/soft-start or VFD — none is integrated.
Max suction and ambient temperature is 25 °C for the rated total pressure differences. Mount so the motor cooling air and the blower intake are not recirculating hot air; exceeding 25 °C requires re-rating against the curve, not just a higher trip setting.
No piping, silencers, filters, valves, VFD, starter or flexible connectors are part of the blower delivery; the data sheet covers only the blower and motor. Order mating flanges/flexible sleeves and inlet/outlet silencers separately, and plan periodic bearing and filter service per the instruction manual.