Elmo Rietschle 2BH1410
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1410

Elmo Rietschle 2BH1410 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -310 mbar, Motor power 2 kW, Noise level 68 dB.

The 2BH1410 is a side-channel blower from the G-BH1 series, driven by a 3-phase IE3 motor rated 2.50 kW at 50 Hz and 3.00 kW at 60 Hz. It delivers a maximum differential pressure of 420 mbar in pressure mode and -320 mbar in vacuum mode at 50 Hz, with 60 Hz operation extending these to 440 mbar and -350 mbar. This modification is positioned as a mid-range unit in the series, suited for continuous industrial vacuum or pressure duty where IE3 efficiency and IP55 protection are required.

Max. differential pressure
-310 mbar
Motor power
2 kW
Noise level
68 dB
Weight
28 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1410 Current 26528-3006.9IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -310 mbar (50 Hz)
60 Hz: -300 mbar
Motor power 1.75 kW (50 Hz)
60 Hz: 2.00 kW
Noise level 65 dB (50 Hz)
60 Hz: 68 dB
Max. differential pressure vacuum mfr -300 mbar (60 Hz)
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Order No. mfr 2BH1410-0HK31
Max. differential pressure (alt 50 Hz) mfr 280 mbar (50 Hz)
Max. differential pressure (alt 60 Hz) mfr 250 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 28 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 6.9 A (50 Hz)
60 Hz: 7.8 / 3.9 A
Frequency 50/60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Rated voltage mfr 220-240 Δ / 380-420 Y V (50 Hz)
Rated voltage mfr 440-480 Y V (60 Hz)
Rated current mfr 8.8 Δ / 5.1 Y A (50 Hz)
Rated current mfr 5.2 A (60 Hz)
Power consumption at pump shaft mfr 2.50 kW (50 Hz)
Power consumption at pump shaft mfr 3.00 kW (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Operating Conditions, Environment & Protection
Ambient temperature limit 25 degC
Protection rating IP55
Sound pressure level mfr 65 dB(A) (50 Hz)
Sound pressure level mfr 68 dB(A) (60 Hz)

Description

Construction and series positioning

Performance and operating behavior

Installation and operation

Integration & Operating Notes

Electrical
Motor is not inverter-rated as standard

The IE3 motor is designed for direct-on-line operation at 50 or 60 Hz. If variable speed control is required, the motor insulation and bearing currents must be evaluated; Elmo Rietschle must be consulted to confirm suitability and any derating. Unapproved VFD use can cause winding failure or reduced bearing life.

Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)
Process Limits
Differential pressure limits differ by frequency

At 50 Hz, the maximum pressure differential is 280 mbar and vacuum differential is -310 mbar. At 60 Hz, these are 250 mbar and -300 mbar. Operating beyond these limits will cause overheating and potential motor overload. Ensure the system's pressure relief or bypass is set below these values.

Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)
Mounting
Mount on rigid, vibration-isolated base

The blower weighs approximately 28 kg and generates vibration during operation. Mount on a flat, rigid surface using the designated mounting holes. Use anti-vibration mounts if the unit is installed near sensitive equipment or in a structure that could transmit vibration. Ensure the motor cooling air intake and exhaust are not restricted.

Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)
Environment
IP55 protection permits outdoor use with caution

The IP55 rating protects against dust and water jets, allowing outdoor installation. However, the motor cooling air path must remain clear, and the unit should be shielded from direct sunlight and heavy rain to prevent condensation inside the motor. Ambient temperature limit is 25 °C per the data sheet; consult the manual for any additional conditions.

Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)
Maintenance
No scheduled maintenance intervals provided

The provided data sheet does not list maintenance intervals or consumables. In practice, inspect and clean the impeller and inlet filter regularly, check motor bearings for noise and play, and verify electrical connections annually. Refer to the full instruction manual for detailed service schedules and spare parts.

Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)

Selection & Integration Q&A

When should I choose the 2BH1410 over the smaller 2BH1014 or larger 2BH1023?

Choose the 2BH1410 when your required pressure differential is up to 280 mbar (50 Hz) or 250 mbar (60 Hz) and vacuum differential is up to -310 mbar (50 Hz) or -300 mbar (60 Hz), and flow demand fits its mid-range envelope. The 2BH1014 offers lower power and pressure, while the 2BH1023 provides higher capacity. Select based on your system's pressure-flow operating point, not just maximum ratings.

Can I use a standard variable frequency drive with the 2BH1410's IE3 motor?

The IE3 motor is not inverter-duty rated as standard. Using a VFD may require additional motor insulation, bearing protection, and derating. Consult Elmo Rietschle before installing a VFD; unapproved use can void warranty and cause premature failure.

What are the ambient temperature and duty cycle limits for the 2BH1410?

The data sheet lists an ambient temperature limit of 25 °C. Duty cycle is not specified in the provided facts; the motor is rated for continuous duty (S1) at the stated power, but actual limits depend on cooling and altitude. Refer to the full instruction manual for any altitude derating and additional conditions.

What accessories or cables are included with the 2BH1410, and what maintenance is required?

The base delivery includes the blower only; power cables, motor protection, and mounting hardware are not included. No maintenance schedule is provided in the data sheet. Regularly inspect and clean the impeller and motor cooling passages, and check electrical connections. Consult the manual for detailed service intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1410 IE3 vacuum pump (EN)
Datasheet ·316,2 КБ ·2 pp.
View PDF