Elmo Rietschle 2BH1510
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1510

Elmo Rietschle 2BH1510 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -400 mbar, Motor power 3.45 kW, Noise level 71 dB.

The 2BH1510 is a single-stage side-channel blower from Elmo Rietschle's G-BH1 series, driven by an IE3 efficiency-class motor. It delivers 410 m³/h suction capacity and achieves a maximum vacuum of -370 mbar at 50 Hz (-400 mbar at 60 Hz) or a maximum pressure of 380 mbar, making it suitable for vacuum or pressure duty in industrial processes. Its IP55 protection and F-class insulation support reliable operation in demanding environments.

Max. differential pressure
-400 mbar
Motor power
3.45 kW
Noise level
71 dB
Weight
48 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1510 Current 47148-4007.6–15.2IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -370 mbar (50 Hz)
60 Hz: -400 mbar
Motor power 3.45 kW (50 Hz)
60 Hz: 4.0 kW
Noise level 71 dB (50 Hz)
60 Hz: 73 dB
Suction capacity mfr 410 m3/h (50 Hz, vacuum, 60 Hz? see doc)
Max. differential pressure vacuum mfr -400 mbar (60 Hz)
Order No. mfr 2BH1510-1HQ46
Vacuum mfr -370 mbar (50 Hz)
Order No. mfr 2BH1510-1HQ57 (50 Hz)
Vacuum mfr -410 mbar (60 Hz)
Order No. mfr 2BH1510-1HQ57 (60 Hz)
Approvals mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Pressure (alt 50 Hz) mfr 410 mbar (50 Hz)
Pressure (alt 60 Hz) mfr 380 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 48 kg (50 Hz)
60 Hz: 48 kg
Electrical, Power & Drive Specifications
Current 13.3 A (50 Hz)
60 Hz: 15.2 / 7.6 A
Frequency 50/60 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Power consumption at pump shaft mfr 3.45 kW (50 Hz)
Power consumption at pump shaft mfr 4.0 kW (60 Hz)
Efficiency class mfr IE3
Efficiency class mfr NP (NEMA Premium) (60 Hz)
Efficiency class mfr IE3 (50 Hz)
Voltage tolerance mfr ±10 % (three-phase motors)
Frequency tolerance mfr ±2 %
Voltage (alt 60 Hz) mfr 230 / 460 V (60 Hz)
Current (alt 60 Hz) mfr 13.2 / 6.6 A (60 Hz)
Voltage (alt 50 Hz) mfr 220-240 / 380-420 V (50 Hz)
Current (alt 50 Hz) mfr 11.6 / 6.7 A (50 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 70 dB(A) (50 Hz)
Sound pressure level mfr 73 dB(A) (60 Hz)

Description

Construction and series positioning

Performance and behavior

Installation and operation

Integration & Operating Notes

Electrical
Motor current must not exceed 11.6 A in delta at 50 Hz

Exceeding the rated current can overheat the motor and damage insulation. The IE3 motor draws 11.6 A in delta (220–240 V) and 6.7 A in star (380–420 V) at 50 Hz; at 60 Hz, 6.6 A in star (440–480 V). Ensure protection devices are set accordingly and account for inrush current.

Technical Data Sheet — 2BH1510 IE3 vacuum pump (EN
Process Limits
Maximum vacuum is -370 mbar at 50 Hz and -400 mbar at 60 Hz

Operating beyond these vacuum levels may cause overheating or mechanical stress. The maximum pressure is 380 mbar for both frequencies. Use a vacuum relief valve or pressure relief valve to prevent exceeding these limits, especially during transient conditions or blockages.

Technical Data Sheet — 2BH1510 IE3 vacuum pump (EN
Maintenance
Regularly inspect and clean the impeller and inlet filter

Dust and debris can accumulate on the impeller, reducing performance and causing imbalance. The data sheet does not specify maintenance intervals, but typical practice for side-channel blowers is to check every 500 operating hours and clean or replace the filter as needed. Bearings are sealed and require no lubrication.

Technical Data Sheet — 2BH1510 IE3 vacuum pump (EN

Selection & Integration Q&A

When should I choose the 2BH1510 instead of a smaller sibling like the 2BH1023?

Choose the 2BH1510 when your process requires up to 410 m³/h suction capacity and vacuum to -370 mbar (50 Hz) or -400 mbar (60 Hz). Smaller siblings like the 2BH1023 offer lower capacity and are better for lower flow demands. The 2BH1510 also provides higher pressure (380 mbar) and is IE3 rated for energy efficiency.

What are the requirements for the power supply and motor protection when integrating this blower?

The motor is dual-voltage: 220–240 V Δ / 380–420 V Y at 50 Hz, or 440–480 V Y at 60 Hz. Use a motor protection circuit breaker set to the rated current (11.6 A Δ or 6.7 A Y at 50 Hz; 6.6 A Y at 60 Hz). Ensure the supply can handle the starting current, and consider a soft starter or star-delta starter for larger installations.

What environmental conditions are acceptable for installing the 2BH1510?

The IP55 rating allows operation in dusty and humid environments, but the blower should be protected from direct water jets and ensure ambient temperature does not exceed the motor's rating (typically 40°C). Provide sufficient ventilation to dissipate heat, especially when operating near maximum pressure or vacuum.

What maintenance items and accessories are recommended but not included with the base blower?

The base delivery includes the blower only. Recommended accessories include inlet filters, vacuum/pressure relief valves, and flexible connectors to reduce vibration. Maintenance items include replacement filters and periodic inspection of the impeller. No specific maintenance schedule is provided in the data sheet; follow general practice for side-channel blowers.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1510 IE3 vacuum pump (EN)
Datasheet ·1,0 МБ ·2 pp.
View PDF