Elmo Rietschle 2BH1590
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH1590

Elmo Rietschle 2BH1590 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -220 mbar, Motor power 1.3 kW, Noise level 61 dB.

The 2BH1590 is a side-channel (regenerative) blower from the Elmo Rietschle G-BH1 series, built as a 2BH1400-1AQ27 with a 1.60 kW IE3 three-phase motor, IP55 protection and class F insulation. It delivers up to 210 mbar gauge in compressor mode and -220 mbar in vacuum mode, with a 64 dB(A) sound pressure level and 21 kg approximate weight. This modification is intended for continuous-duty air movement in pneumatic conveying, vacuum holding and low-pressure compression circuits where oil-free operation and compact footprint are required.

Max. differential pressure
-220 mbar
Motor power
1.3 kW
Noise level
61 dB
Weight
21 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1590 Current 1.36121-1902.75IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1600 1.7572311309.9IP55
2BH1610 2.575481606IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -190 mbar (50 Hz)
60 Hz: -220 mbar
Motor power 1.30 kW (50 Hz)
60 Hz: 1.60 kW
Noise level 61 dB (50 Hz)
60 Hz: 64 dB
Typ-Nr. mfr 2BH1400-1AQ27
Frequenz mfr 50 Hz (50 Hz)
Frequenz mfr 60 Hz (60 Hz)
Max. Differenzdruck Vakuum mfr -220 mbar
Max. Differenzdruck Verdichter mfr 210 mbar
Effizienzklasse mfr IE3
Model designation mfr 2BH1400
Max. differential pressure vacuum mfr -180 mbar (50 Hz, D)
Max. differential pressure compressor mfr 170 mbar (50 Hz, D)
Max. differential pressure vacuum mfr -170 mbar (60 Hz, IE3)
Max. differential pressure compressor mfr 160 mbar (60 Hz, IE3)
Max. differential pressure vacuum mfr -170 mbar (60 Hz, NP)
Max. differential pressure compressor mfr 160 mbar (60 Hz, NP)
Order number mfr 2BH1400-1AK11
Max. Differenzdruck Verdichter (alt 50 Hz) mfr 220 mbar (50 Hz)
Max. Differenzdruck Verdichter (alt 60 Hz) mfr 210 mbar (60 Hz)
Frequenz (alt var) mfr 60 Hz
Dimensions, Weight & Mechanical Design
Weight 21 kg
Electrical, Power & Drive Specifications
Current 4.9 A (50 Hz, 220-240 D)
50 Hz, 380-420 U: 2.85 A · 60 Hz, 220-240 UU: 5.5 A · 60 Hz, 440-480 U: 2.75 A · 60 Hz, 230 UU: 5.5 A · 60 Hz, 460 U: 2.75 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 220-240 D V (50 Hz)
60 Hz: 220-240 UU V
Spannungsbereich mfr 380-420 D / 660-725 U V (50 Hz)
Spannungsbereich mfr 460 D V (60 Hz)
Strom mfr 2,75 A (50 Hz)
Strom mfr 2,75 A (60 Hz)
Strom mfr 2,75 A (60 Hz (460 V))
Leistung mfr 1,60 kW (50 Hz)
Leistung mfr 1,60 kW (60 Hz)
Leistung mfr 1,60 kW (60 Hz (460 V))
Efficiency class mfr IE3
Rated voltage mfr 190-210 V (50 Hz, D)
Rated voltage mfr 190-210 UU / 380-420 U V (60 Hz, IE3)
Rated voltage mfr 200 UU V (60 Hz, NP)
voltage (alt 50 Hz) mfr 380-420 U V (50 Hz)
voltage (alt 60 Hz) mfr 460 U V (60 Hz)
Operating Conditions, Environment & Protection
Protection rating IP55
Schalldruckpegel mfr 64 dB(A)
Sound pressure level mfr 61 dB(A) (50 Hz, D)
Sound pressure level mfr 64 dB(A) (60 Hz, IE3)
Sound pressure level mfr 64 dB(A) (60 Hz, NP)

Description

Construction and series positioning

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Mounting
Allow unobstructed cooling air flow around the motor fins

The IP55 motor relies on surface cooling; mounting in a confined space or with restricted airflow will raise winding temperature and may shorten insulation life. Maintain at least the clearance recommended in the installation instructions and avoid recirculating hot exhaust air into the intake.

Technical Data Sheet — 2BH1590 IE3 compressor (DE), general installation notes
Maintenance
Inspect and clean the impeller and channel periodically

Dust and debris accumulating in the side channel reduce performance and can cause imbalance. The service interval depends on the process air cleanliness; in dusty environments, monthly inspection is advised. No lubrication is required for the blower bearings (sealed-for-life), but motor bearings should be checked per the manual's schedule.

Technical Data Sheet — 2BH1590 IE3 compressor (DE), maintenance section

Selection & Integration Q&A

When should I choose the 2BH1590 instead of a smaller sibling like the 2BH1023?

Choose the 2BH1590 when your process needs up to 210 mbar compression or -220 mbar vacuum and the 1.60 kW motor is sufficient. The smaller 2BH1023 delivers lower pressure and flow; if your duty point falls within its curve, it saves space and weight. Select the 2BH1590 when higher differential pressure is the primary requirement and the 21 kg weight is acceptable.

What supply and protection must be provided for the 2BH1590 motor?

Provide a three-phase supply matching the nameplate: 380–420 V delta or 660–725 V star at 50 Hz, or 460 V delta at 60 Hz. Use a motor starter with overload protection set to 2.75 A. The IP55 enclosure does not include a built-in disconnect; install a lockable isolator within sight of the blower.

Can the 2BH1590 be installed outdoors or in a wash-down area?

IP55 protects against dust and water jets, so wash-down is permissible, but the blower is not designed for outdoor installation without a protective cover. Avoid direct rain and ensure the motor cooling air is clean. Ambient temperature limits are not stated in the digest; consult the manual for derating above 40 °C.

What maintenance parts and accessories are not included with the base blower?

The base delivery includes the blower only. You must separately order: flexible connectors to isolate vibration, inlet/outlet silencers if lower noise is needed, a suction filter for dusty air, and a motor protection switch or contactor. Spare impellers and gaskets are available as service parts; no lubrication is supplied because bearings are sealed-for-life.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1590 IE3 compressor (DE)
Datasheet ·689,5 КБ ·2 pp.