Elmo Rietschle 2BH1610 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure 670 mbar, Motor power 2.5 kW, Noise level 69 dB.

Side-channel regenerative blower 2BH1 610 from the G-BH 1 N series, built as a single-stage (or multi-stage, per variant) contactless impeller unit driven by an IE3 three-phase motor in IP55 / class F. It is the largest frame in the 2BH10xx sibling group (1009, 1014, 1015, 1023), so it is selected when the smaller frames cannot reach the required pressure ratio at the duty point. Used as a vacuum or pressure source in pneumatic conveying, aeration and holding-air circuits.

Max. differential pressure
670 mbar
Motor power
2.5 kW
Noise level
69 dB
Weight
85 kg

Elmo Rietschle G-BH1 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBWeight, kgMax. differential pressure, mbarCurrent, AProtection rating
2BH1610 Current 2.575481606IP55
2BH1009 ——————
2BH1014 0.325711-553.2–6.5IP55
2BH1015 1.36421-1808–16IP55
2BH1023 1.756969-19010–20IP55
2BH1035 2.26470-14014.3–27IP55
2BH1100 0.25310-1201.39 Δ / 0.80 YIP 55
2BH1200 0.294057-401.38 0.8 YIP55
2BH1300 0.2910051-1001.9IP 55
2BH1310 0.75616-2503.8 Δ / 2.20 YIP55
2BH1330 0.298051—1.74 Δ / 1.0 YIP55
2BH1400 0.956116-1805.6IP55
2BH1410 26528-3006.9IP55
2BH1430 1.164161104.2IP55
2BH1490 0.956116-1404.8 VVIP55
2BH1500 0.956521-904.2IP55
2BH1510 47148-4007.6–15.2IP55
2BH1530 1.66925-904.7IP55
2BH1590 1.36121-1902.75IP55
2BH1600 1.7572311309.9IP55
2BH1630 2.56436-16017.1IP55
2BH1640 4.66565-240–26017.1IP55
2BH1690 2.56434-2009.9IP55
2BH1800 5.87713126011–22IP55
2BH1810 9.974188-46030.8IP55
2BH1830 5.875133-16019.4IP55
2BH1900 8.671183-19030.8IP55
2BH1910 12.676295-22026.4IP55
2BH1930 8.675212-8017.6–35.2IP55
2BH1940 19.973303-15063.1IP55
2BH1943 17.377330-16072.2 UU / 36.1 UIP55

Full specifications

Core Performance & Functional Specifications
Max. differential pressure 160 mbar (50 Hz, size 1, IE3)
60 Hz, size 1, IE3: 120 mbar · 50 Hz, size 2, IE3: 260 mbar · 60 Hz, size 2, IE3: 200 mbar · 50 Hz, size 3, IE3: 360 mbar · 60 Hz, size 3, IE3: 320 mbar · 50 Hz, size 4, IE3: 530 mbar · 60 Hz, size 4, IE3: 490 mbar · 50 Hz, size 5, IE3: 610 mbar · 60 Hz, size 5, IE3: 670 mbar
Motor power 2.50 kW (50 Hz, size 1, IE3)
60 Hz, size 1, IE3: 3.00 kW · 50 Hz, size 2, IE3: 3.45 kW · 60 Hz, size 2, IE3: 4.0 kW · 50 Hz, size 3, IE3: 4.6 kW · 60 Hz, size 3, IE3: 5.3 kW · 50 Hz, size 4, IE3: 6.3 kW · 60 Hz, size 4, IE3: 7.3 kW · 50 Hz, size 5, IE3: 8.6 kW · 60 Hz, size 5, IE3: 9.9 kW
Noise level 69 dB (50 Hz, size 1, IE3)
60 Hz, size 1, IE3: 73 dB · 50 Hz, size 2, IE3: 75 dB · 60 Hz, size 2, IE3: 73 dB · 50 Hz, size 3, IE3: 67 dB · 60 Hz, size 3, IE3: 71 dB · 50 Hz, size 4, IE3: 71 dB · 60 Hz, size 4, IE3: 75 dB · 50 Hz, size 5, IE3: 71 dB · 60 Hz, size 5, IE3: 75 dB
Series mfr G-BH 1 N
Model mfr 2BH1 610
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Reference atmospheric pressure mfr 1013 mbar
Performance curve tolerance mfr ± 10 %
Max. differential pressure vacuum mfr -420 mbar (50 Hz)
Max. differential pressure vacuum mfr -440 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 48 kg (size 1)
size 2: 58 kg · size 3: 65 kg · size 4: 73 kg · size 5: 85 kg
Number of stages UL 1450 and CAN/CSA C22.2 No. 68-09 (E225239)
Electrical, Power & Drive Specifications
Current 6.0 A (50 Hz)
50 Hz 190-210 V: 2.50 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 / 380-420 V (50 Hz)
60 Hz: 200 V
Motor efficiency class mfr IE3
Voltage tolerance mfr +/-10 %
Frequency tolerance mfr +/- 2 %
Possible converter input voltage mfr 500 V
Rated voltage mfr 200 V (60 Hz)
Rated current mfr 35.2 A (60 Hz)
Rated current mfr 30.8 A (50 Hz)
Efficiency class mfr IE3 (50 Hz)
Efficiency class mfr NP (60 Hz)
Interfaces, Connections & Control
Inlet connection F
Operating Conditions, Environment & Protection
Protection rating IP55
Operating temperature 25 degC
Sound pressure level tolerance mfr ±3 dB(A)
Sound pressure level mfr 67 dB(A) (50 Hz)
Sound pressure level mfr 71 dB(A) (60 Hz)
Standards, Safety & General Data
Measuring surface sound pressure level standard mfr EN ISO 3744

Description

Construction and series position

Behavior under load and media

Installation, connection and control

Integration & Operating Notes

Electrical
Match winding variant to actual site voltage before ordering

The 2BH1 610 is offered in many winding variants from 190–210/380–420 V up to 475–525/550–600 V plus 220–240 V single-voltage types. Supplying the wrong variant outside ±10 % voltage and ±2 % frequency tolerance shifts speed and invalidates the published curve.

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Process Limits
Suction and ambient temperature capped at 25 °C for rated data

Published pressure differences apply only up to 25 °C suction and ambient. Above this the achievable pressure ratio drops and motor thermal margin shrinks; re-rate against the curve or add cooling rather than relying on the nameplate figure.

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Control & I/O
External starter and overload protection must be engineered

The blower has no integrated control or protection. The panel must provide contactor/soft-start or VFD, overload relay set to motor FLA, and any pressure/flow interlocks; converter input voltage up to 500 V is allowed.

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Mounting
Keep motor cooling air and intake paths separate

IP55 protects the motor from dust and water jets but not immersion. Mount so cooling air is not recirculated from the blower discharge and the intake is not obstructed; flexible connectors reduce vibration transmission to piping.

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Maintenance
Plan bearing and filter service per instruction manual

The data sheet gives no service interval; bearing lubrication/replacement and inlet filter cleaning follow the instruction manual. Because the impeller is non-contacting, wear is concentrated in bearings and filters, so schedule checks accordingly.

Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)

Selection & Integration Q&A

When should I specify the 2BH1 610 instead of the smaller 2BH1009/1014/1015/1023 frames?

Pick the 610 only when the required flow at the target pressure difference falls outside the curves of the smaller 2BH10xx frames; it is the largest frame in that group, so oversizing wastes energy and adds noise. If a smaller sibling meets the duty point with margin, use it.

What supply and protection does the 2BH1 610 motor need, and can it run on a VFD?

Three-phase supply within ±10 % voltage and ±2 % frequency of the ordered winding; IE3 motor, IP55, class F. Converter operation is permitted with converter input voltage up to 500 V. Provide external overload protection and a contactor/soft-start or VFD — none is integrated.

What ambient and suction-temperature limits apply, and how do they affect mounting?

Max suction and ambient temperature is 25 °C for the rated total pressure differences. Mount so the motor cooling air and the blower intake are not recirculating hot air; exceeding 25 °C requires re-rating against the curve, not just a higher trip setting.

What is not included in the base delivery that I must plan for?

No piping, silencers, filters, valves, VFD, starter or flexible connectors are part of the blower delivery; the data sheet covers only the blower and motor. Order mating flanges/flexible sleeves and inlet/outlet silencers separately, and plan periodic bearing and filter service per the instruction manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH1610 IE3 vacuum pump (EN)
Datasheet ·367,6 КБ ·2 pp.
View PDF