Elmo Rietschle 2BH1830
Elmo Rietschle 2BH1830 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -160 mbar, Motor power 5.1 kW, Noise level 75 dB.
The 2BH1830 is a side-channel (regenerative) blower from Elmo Rietschle's G-BH1 series, built as a size-2 machine with an IE3 premium-efficiency motor and IP55 protection. It delivers up to ±200 mbar differential at 50 Hz (−200 mbar vacuum / +200 mbar pressure at 50 Hz; −160 mbar vacuum / +130 mbar pressure at 60 Hz) from a 5.1 kW (50 Hz) / 5.8 kW (60 Hz) drive, making it the higher-capacity choice among the 2BH10xx siblings. It is intended for continuous vacuum or pressure duty in pneumatic conveying, aeration, or extraction circuits where a compact, oil-free ring blower is required.
Elmo Rietschle G-BH1 Series — Model Comparison & Selection
| Model | Motor power, kW | Noise level, dB | Weight, kg | Max. differential pressure, mbar | Current, A | Protection rating |
|---|---|---|---|---|---|---|
| 2BH1830 Current | 5.8 | 75 | 133 | -160 | 19.4 | IP55 |
| 2BH1009 | — | — | — | — | — | — |
| 2BH1014 | 0.32 | 57 | 11 | -55 | 3.2–6.5 | IP55 |
| 2BH1015 | 1.3 | 64 | 21 | -180 | 8–16 | IP55 |
| 2BH1023 | 1.75 | 69 | 69 | -190 | 10–20 | IP55 |
| 2BH1035 | 2.2 | 64 | 70 | -140 | 14.3–27 | IP55 |
| 2BH1100 | 0.2 | 53 | 10 | -120 | 1.39 Δ / 0.80 Y | IP 55 |
| 2BH1200 | 0.29 | 40 | 57 | -40 | 1.38 0.8 Y | IP55 |
| 2BH1300 | 0.29 | 100 | 51 | -100 | 1.9 | IP 55 |
| 2BH1310 | 0.7 | 56 | 16 | -250 | 3.8 Δ / 2.20 Y | IP55 |
| 2BH1330 | 0.29 | 80 | 51 | — | 1.74 Δ / 1.0 Y | IP55 |
| 2BH1400 | 0.95 | 61 | 16 | -180 | 5.6 | IP55 |
| 2BH1410 | 2 | 65 | 28 | -300 | 6.9 | IP55 |
| 2BH1430 | 1.1 | 64 | 16 | 110 | 4.2 | IP55 |
| 2BH1490 | 0.95 | 61 | 16 | -140 | 4.8 VV | IP55 |
| 2BH1500 | 0.95 | 65 | 21 | -90 | 4.2 | IP55 |
| 2BH1510 | 4 | 71 | 48 | -400 | 7.6–15.2 | IP55 |
| 2BH1530 | 1.6 | 69 | 25 | -90 | 4.7 | IP55 |
| 2BH1590 | 1.3 | 61 | 21 | -190 | 2.75 | IP55 |
| 2BH1600 | 1.75 | 72 | 31 | 130 | 9.9 | IP55 |
| 2BH1610 | 2.5 | 75 | 48 | 160 | 6 | IP55 |
| 2BH1630 | 2.5 | 64 | 36 | -160 | 17.1 | IP55 |
| 2BH1640 | 4.6 | 65 | 65 | -240–260 | 17.1 | IP55 |
| 2BH1690 | 2.5 | 64 | 34 | -200 | 9.9 | IP55 |
| 2BH1800 | 5.8 | 77 | 131 | 260 | 11–22 | IP55 |
| 2BH1810 | 9.9 | 74 | 188 | -460 | 30.8 | IP55 |
| 2BH1900 | 8.6 | 71 | 183 | -190 | 30.8 | IP55 |
| 2BH1910 | 12.6 | 76 | 295 | -220 | 26.4 | IP55 |
| 2BH1930 | 8.6 | 75 | 212 | -80 | 17.6–35.2 | IP55 |
| 2BH1940 | 19.9 | 73 | 303 | -150 | 63.1 | IP55 |
| 2BH1943 | 17.3 | 77 | 330 | -160 | 72.2 UU / 36.1 U | IP55 |
Full specifications
| Max. differential pressure | -200 mbar (50 Hz) 60 Hz: -160 mbar |
| Motor power | 5.1 kW (50 Hz) 60 Hz: 5.8 kW |
| Noise level | 71 dB(A) (50 Hz) 60 Hz: 75 dB(A) |
| Max. differential pressure vacuum mfr | -160 mbar (60 Hz) |
| Approval mfr | UL 1450, CAN/CSA C22.2 No. 68-09 (E225239) |
| Weight | 133 kg |
| Weight approx. mfr | 130 kg |
| Current | 19.4 A (50 Hz) 60 Hz: 22.0 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-480 V |
| Efficiency class mfr | IE3 |
| Voltage tolerance mfr | ±10 % |
| Frequency tolerance mfr | ±2 % |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AK11) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AK21) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AK16) |
| Rated voltage mfr | 220-240 Δ / 380-420 Y V (50 Hz, 2BH1830-2AK16) |
| Rated voltage mfr | 220-240 YY / 440-480 Y V (60 Hz, 2BH1830-2AK16) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AK26) |
| Rated voltage mfr | 220-240 Δ / 380-420 Y V (50 Hz, 2BH1830-2AK26) |
| Rated voltage mfr | 220-240 YY / 440-480 Y V (60 Hz, 2BH1830-2AK26) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AQ13) |
| Rated voltage mfr | 500 Y V (50 Hz, 2BH1830-2AQ13) |
| Rated voltage mfr | 575 Y V (60 Hz, 2BH1830-2AQ13) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AQ23) |
| Rated voltage mfr | 500 Y V (50 Hz, 2BH1830-2AQ23) |
| Rated voltage mfr | 575 Y V (60 Hz, 2BH1830-2AQ23) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AQ17) |
| Rated voltage mfr | 380-420 Δ / 660-725 Y V (50 Hz, 2BH1830-2AQ17) |
| Rated voltage mfr | 440-480 Δ V (60 Hz, 2BH1830-2AQ17) |
| Efficiency class mfr | IE3 (50 Hz, 2BH1830-2AQ27) |
| Rated voltage mfr | 380-420 Δ / 660-725 Y V (50 Hz, 2BH1830-2AQ27) |
| Rated voltage mfr | 440-480 Δ V (60 Hz, 2BH1830-2AQ27) |
| Current (alt 60 Hz) mfr | 11.0 A (60 Hz) |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Operating temperature | 25 degC |
| Sound pressure level mfr | 71 dB(A) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AK11) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AK11) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AK21) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AK21) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AK16) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AK16) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AK26) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AK26) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AQ13) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AQ13) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AQ23) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AQ23) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AQ17) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AQ17) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, 2BH1830-2AQ27) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, 2BH1830-2AQ27) |
Description
Construction and series positioning
- The 2BH1830 is a size-2 G-BH1 side-channel blower, distinguished from the smaller 2BH1009/1014/1015/1023 siblings by its larger impeller and motor frame, which raise the achievable differential pressure and flow capacity.
- It uses a three-phase IE3 induction motor (insulation class F, IP55) directly coupled to the ring impeller; no belts or external gearing are involved.
- The HT designation in the data sheet indicates a high-temperature configuration; the motor is wound for dual voltage (220–240 Δ / 380–420 Y at 50 Hz; 230 Δ / 460 Y at 60 Hz) with ±10 % voltage and ±2 % frequency tolerance.
Performance behaviour
- Maximum differential pressure is symmetric: +200 mbar in pressure mode and −200 mbar in vacuum mode at 50 Hz. At 60 Hz the achievable differential falls to +130 mbar / −160 mbar, so the machine should be sized on the 60 Hz figures if that frequency is used.
- Power draw rises from 5.1 kW at 50 Hz to 5.8 kW at 60 Hz; current is 18.7 A Δ / 9.7 A Y at 50 Hz and 16.7 A Δ / 9.4 A Y at 60 Hz. The blower is a constant-speed machine — flow is set by the system resistance, not by internal modulation.
- Sound pressure is 71 dB(A) at the standard measuring point; because the unit is a positive-displacement ring blower, noise and power both increase as differential pressure rises toward the maximum.
Installation and operation
- The machine is foot-mounted and weighs approximately 130 kg; it must be bolted to a rigid, level base capable of carrying the weight and the reaction torque.
- Electrical connection is to a three-phase supply through a suitable motor protection device; the IE3 motor requires correct delta/star linking for the site voltage. The IP55 enclosure allows outdoor or washdown-adjacent installation, but the cooling-air path must remain unobstructed.
- No control electronics are integrated: start/stop, overload protection and any process interlocks must be provided by the panel. The data sheet lists multiple order codes (2BH1830-2AK11, -2AK21, -2AK16, -2AK26, -2AQ13, -2AQ23, -2AQ17, -2AQ27) covering voltage and configuration variants, so the exact order code must be confirmed before ordering.
Integration & Operating Notes
Operation outside these tolerances will shift the motor's operating point and can overheat the winding or reduce available differential pressure. Sites with weak grids or generator supply should be checked against these limits; a 60 Hz supply also lowers the maximum differential pressure to +130 / −160 mbar, so the process must be sized for the actual frequency.
Selection & Integration Q&A
Pick the 2BH1830 when the duty point needs up to ±200 mbar differential at 50 Hz and the flow that a size-2 impeller provides. The 2BH1009/1014/1015/1023 siblings are smaller frames with lower capacity; they suit lower-pressure or lower-flow duties where the 1830 would be oversized and draw unnecessary power.
A three-phase supply within ±10 % voltage and ±2 % frequency, linked for the site voltage (e.g. 380–420 V star at 50 Hz), with a motor protection device set to 18.7 A Δ / 9.7 A Y at 50 Hz. No starter or VFD is included, so start/stop and overload protection are panel-side responsibilities.
The base delivery is the blower with IE3 motor only; process connections, silencers, filters, relief valves, flexible connectors and electrical cables are not included. Confirm the exact order code (e.g. 2BH1830-2AK11 vs -2AQ13) because it encodes voltage and configuration variants that affect the ancillaries required.