Peter Huber Kältemaschinenbau Unistat P905w Dynamisches
Peter Huber Kältemaschinenbau Unistat P905w Dynamisches — Temperature control units.
The Unistat P905w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump, covering -90 to 250 °C. Its high-discharge-pressure pump targets high-pressure-drop circuits such as flow-through chemistry and semiconductor processes. It is the water-cooled P-variant of the Unistat 905 series, requiring 460 V 3~ 60 Hz and facility cooling water.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat P905w Dynamisches Current | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 1005w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825 Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -90...250 °C |
| Weight | 261 kg |
| Current consumption | 23 A (max) |
| Power supply | 460V 3~ 60Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water differential pressure | 1 bar (min) |
| Cooling Water Pressure | 6 bar (max) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with a magnetically coupled, stainless-steel circulating pump; the 'P' designation denotes the high-discharge-pressure pump for high-pressure-drop applications.
- Sits in the Unistat 905 size class; siblings include the 705w, 815w, 1005w and 1015w Dynamisches models, which differ in size class rather than in the P-pump configuration.
- Controller is Pilot ONE with POKO ONE control output; interfaces are Ethernet, USB (Host and Device) and RS232; external Pt100 sensor connection.
- Overall dimensions 540 x 654 x 1500 mm, weight 261 kg, protection rating IP20.
Working range and load behavior
- Temperature range -90 to 250 °C; heating capacity 6 kW.
- Cooling capacity falls to 0.5 kW at -80 °C, so deep-cold loads must be sized against the low-temperature end rather than a nominal mid-range figure.
- Pump delivers 65 l/min at zero head but only 29 l/min at 2.5 bar; maximum delivery pressure is 3 bar. External circuit pressure drop must be checked against this curve.
- Maximum permissible kinematic viscosity is 50 mm²/s; the heat transfer fluid must be verified at the lowest operating temperature.
Installation, connection and operation
- Requires 460 V 3~ 60 Hz supply, 23 A maximum current, 3x25 A fusing; three-phase devices below 63 A are delivered with cable but without a plug.
- Leakage current exceeds 3.5 mA; UL 489 branch-circuit protection is required.
- Water-cooled refrigeration circuit: cooling water connection G1/2 male, 580 l/h at 15 °C, minimum 1 bar differential pressure, maximum 6 bar; cooling water inlet must stay between 5 and 20 °C.
- Ambient temperature 5 to 40 °C; unit must not be installed in an ATEX zone; use with medical devices or direct foodstuff temperature control is not permissible.
- Refrigerant charges: R-452A (1.4 kg, GWP 2141) and R-23 (0.75 kg, GWP 14800), combined CO2 equivalent about 14.1 t.
Integration & Operating Notes
The unit's leakage current exceeds 3.5 mA, so residual-current protection and UL 489 branch-circuit protection must be coordinated by the site electrician; a standard 30 mA RCD may not be suitable without verification.
Three-phase devices below 63 A are delivered with cable but without a plug; the customer must provide the mating plug and complete the connection. Hard-wired connection must be carried out by an electrician.
The water-cooled refrigeration circuit needs 580 l/h at 15 °C with at least 1 bar differential pressure and a maximum of 6 bar; cooling water inlet must stay between 5 and 20 °C. Out-of-range water temperature degrades capacity and creates condensation risk, so pipes must be insulated where condensation can occur.
Maximum permissible kinematic viscosity is 50 mm²/s. Too-viscous fluid at low temperature overloads the pump and reduces heat transfer, so the heat transfer fluid must be checked against this limit at the coldest setpoint.
Horizontal transport damages the compressor, and only an emptied unit may be moved. Casters are not suitable for transport and carry only 25% of total mass symmetrically; use an industrial truck. Leveling feet must be activated and parking brakes engaged before commissioning.
When moving between cold and warm environments, allow about 2 hours acclimation before switching on to prevent condensation-induced electrical faults.
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage. For externally open (bath) applications the expansion vessel must be locked to prevent fluid loss.
In Process Safety mode the controller releases maximum cooling capacity at the overtemperature trigger instead of switching off all poles; this mode requires the compressor to be set to Permanently ON to keep cooling active.
After a power outage the response can be set via Pilot ONE: 'Off/Standby' (default, manual restart) or 'ON/Temperature control active' (automatic restart with a brief INFO allowing cancellation). Choose according to whether unattended restart is acceptable for the process.
The cooling water supply should be shut off even for short downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit.
Work on the coolant circuit must be carried out by approved refrigeration/air-conditioning system contractors. Refrigerant charges are R-452A (1.4 kg, GWP 2141) and R-23 (0.75 kg, GWP 14800), combined CO2 equivalent about 14.1 t, which matters for leak reporting and service.
Selection & Integration Q&A
Choose the P905w when the external circuit has high pressure drop (flow-through chemistry, semiconductor) and needs the high-discharge-pressure pump; the 815w or 1005w differ in size class, so select those when cooling capacity or chamber size, not pump head, is the deciding factor.
A 460 V 3~ 60 Hz supply with 3x25 A fusing and a site-provided three-phase plug (cable delivered without plug), plus cooling water at 580 l/h, 15 °C, 1–6 bar on G1/2 male connections. Pump connections are M30x1.5 AG male; an external Pt100 sensor can be connected.
Install upright at 5–40 °C ambient, IP20, not in an ATEX zone; activate leveling feet and parking brakes. Transport only upright and emptied. Allow 2 h acclimation after temperature changes. Shut off cooling water even overnight. Use with medical devices or direct foodstuff is not permissible.
Periodically check hoses and connections for leaks and quality and replace as needed; clean liquefier fins and the hat-type strainer; inspect heat transfer fluid and replace/rinsed circuit; refrigerant work by approved contractors. The three-phase plug, heat transfer fluid, and drip tray are not included and must be provided by the site.