Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches
Peter Huber Kältemaschinenbau Unistat 1005w Dynamisches — Temperature control units.
The Unistat 1005w Dynamisches is a water-cooled refrigerated heating circulator with a stainless-steel variable-speed pressure pump, covering -120 to 100 °C via a three-stage cascade (R-452A/R-23/R-14). Within the Unistat w-series it is the 10x5 frame size, positioned above the 705w/815w/825w and below the 1015w. It serves externally closed or open temperature control loops requiring 2 kW heating and up to 30 l/min circulation.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat 1005w Dynamisches Current | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825 Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Control output | POKO ONE |
| Expansion volume | 8 l |
| Heating capacity | 2 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | Pressure pump, variable speed |
| External sensor connection | Pt100 |
| Temperature range | -120...100 °C |
| Weight | 340 kg |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G1/2 male |
| Cooling water consumption | 300 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 3 bar |
| Cooling Water Pressure | 6 bar |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Water-cooled refrigerated heating circulator (suffix 'w') with optical level indicator, stainless-steel pump and cooled shaft seal; free-standing 700x804x1520 mm cabinet, 340 kg.
- Three-stage cascade refrigerant circuit: R-452A (A1, H280, GWP 2141, 2.7 t CO2e), R-23 (A1, H280) and R-14 (A1, H280).
- Sits between the 825w and 1015w in the w-series; the 705w/815w/825w are smaller frames, the 1015w the next size up. Unlike the 705w, this model has a plate heat exchanger, so the manual's warning against very dynamic, high-temperature changes recurring at short intervals applies.
- Controller: Pilot ONE with POKO ONE control output; display resolution 0.01 K; interfaces Ethernet, USB host/device and RS232; external Pt100 sensor input.
Working range and load behavior
- Temperature range -120...100 °C; heating capacity 2 kW; pump max. delivery 30 l/min at max. 0.9 bar, falling to 8 l/min at 0.8 bar — external circuit pressure drop must be checked against this curve.
- Cooling is water-side dependent: 300 l/h at 15 °C cooling water with 0 °C flow; cooling power drops and required flow rises as cooling water temperature increases.
- Safety class III/FL: FL-rated fluid must have a fire point ≥65 °C; ethanol only under supervision.
- Process Safety mode releases maximum cooling at the OT trigger instead of switching off all poles, and requires the compressor set to Permanently ON.
Installation, connection and operation
- 400 V 3~ 50 Hz, max. current 16.5 A, fusing 3x20 A; three-phase units below 63 A are delivered with cable but without plug.
- Cooling water: G1/2 male connections, min. 3 bar differential pressure, max. 6 bar, intake 5–20 °C; insulate pipes if below condensation point.
- Pump connection M30x1.5 AG male; min. filling 3.6 l, 8 l expansion tank.
- Ambient 5–40 °C, IP20, Class A Group 1 to EN55011; not for ATEX zones, medical devices or direct food contact.
Integration & Operating Notes
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. Conversely, externally open (bath) applications require the vessel locked to prevent fluid loss. The setting must be verified before commissioning, not after the first temperature cycle.
In Process Safety mode the controller releases maximum cooling capacity at the OT trigger instead of isolating all poles, which protects exothermic processes and glass breakage scenarios. This mode only functions if the compressor is configured to Permanently ON; otherwise the protective cooling is not available when the trigger is reached.
The Pilot ONE can be set to Off/Standby (default, manual restart) or ON/Temperature control active, and Power Failure Auto resumes temperature control after an outage if it was active. Choose according to whether an unattended restart is safe for the process; the INFO window at startup allows automatic start to be cancelled for a few seconds.
Selection & Integration Q&A
Pick the 1005w when the duty needs the 10x5 frame's 2 kW heating and 30 l/min pump at -120...100 °C with water cooling. The 815w/825w are smaller frames; the 1015w is the next size up. Note the 705w lacks a plate heat exchanger, so the dynamic-change warning applies here but not there.
The process loop must fit the pump curve: 30 l/min max at 0.9 bar, falling to 8 l/min at 0.8 bar, so check external pressure drop. Cooling water needs G1/2 male connections, 3–6 bar differential and 5–20 °C intake; 300 l/h is the reference at 15 °C water with 0 °C flow.
Install upright on leveling feet with brakes engaged, ambient 5–40 °C, IP20 dry location, no ATEX zone. Allow 2 h acclimation after cold/warm moves. Transport only empty and upright. Shut off cooling water even overnight. FL fluid needs fire point ≥65 °C; ethanol only supervised.
Base delivery includes cable but no plug for this <63 A three-phase unit. Plan periodic hose/connection inspection and replacement, hat-type strainer cleaning with circuit drain, liquefier fin cleaning and heat transfer fluid inspection/replacement. A drip tray below the unit is required by the responsible body; refrigerant work needs approved contractors.