Peter Huber Kältemaschinenbau Unistat P825 Dynamisches
Peter Huber Kältemaschinenbau Unistat P825 Dynamisches — Temperature control units.
The Unistat P825 Dynamisches is a free-standing refrigerated heating circulator with an air-cooled two-stage cascade refrigeration machine, covering -85 to 250 °C with a 3 kW heater and a magnetically coupled stainless-steel pump delivering up to 67 l/min at 3 bar. Its high-discharge-pressure 'P' pump distinguishes it from standard Unistat 8xx siblings, targeting externally closed loops with high pressure drop such as flow-through chemistry and semiconductor processes. It serves as a central temperature source in pilot-plant and process-scale systems requiring precise Pt100-based control via the Pilot ONE controller.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat P825 Dynamisches Current | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 1005w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Control output | POKO ONE |
| Heating capacity | 3 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -85...250 °C |
| Weight | 238 kg |
| Current consumption | 16 A (max.) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing refrigerated heating circulator with air-cooled cascade refrigeration (R-452A first stage, R-23 second stage) and optical level indicator; suitable for externally closed and externally open applications.
- The 'P' designation denotes a high-discharge-pressure circulation pump (magnetically coupled, stainless steel, M30x1.5 male connections) for loops with high pressure drop — flow-through chemistry or semiconductor industry — rather than the standard-pressure pump of the 8xx siblings (e.g. Unistat 815w Dynamisches).
- Safety class III / FL per DIN 12876; controller Pilot ONE with POKO ONE control output, 0.01 K display resolution, Ethernet/USB/RS232 interfaces and external Pt100 sensor connection.
Behavior under load and media
- Temperature range -85 to 250 °C; heating capacity 3 kW. Pump curve: 67 l/min max delivery at 3 bar max; 61 l/min at 0.5 bar and 28 l/min at 2.5 bar — verify the external loop pressure drop against this curve before selection.
- Cooling capacity is rated at 20 °C room temperature and derates as ambient rises; ambient operating window is 5–40 °C.
- FL rating requires heat transfer fluid with fire point ≥ 65 °C; ethanol use only under supervision. Low-level protection via pressure sensor in the fluid circuit — air pockets or low fill interrupt circulation and temperature control.
- Process Safety mode releases maximum cooling at the OT trigger instead of all-pole switch-off (compressor must be set Permanently ON).
Installation, connection and control
- 400 V 3~ 50 Hz supply, 16 A max current, 3x20 A fusing; delivered with cable but without plug (three-phase <63 A). Leakage current >3.5 mA requires RCD/earthing design. Voltage tolerance ±5%, frequency ±2%, but opposite worst-case combination not allowed.
- IP20, indoor dry location only; not permitted in ATEX zones; Class A Group 1 per EN55011 (EMC measures may be needed in light-industrial settings).
- Pump connections M30x1.5 male, bore shape Y (60°) per DIN 3863; hoses require ball socket DIN 3863 and sleeve nut DIN 3870. Expansion vessel must remain unlocked for externally closed loops and locked for open bath applications.
- Pilot ONE offers power-failure restart behavior (Off/Standby default or auto-resume), Delta T limiter, freeze protection, setpoint thresholds, and program/clock functions.
Integration & Operating Notes
For externally closed applications the expansion vessel must remain unlocked; locking it causes overpressure damage to the application. For externally open (bath) applications it must be locked to prevent fluid loss. Confirm the application type before commissioning and set the isolating sleeve/valve accordingly.
Pilot ONE can be configured to remain in Off/Standby after power restoration (default, manual start required) or to resume temperature control automatically. Choose the mode according to whether an unattended restart is safe for the process; the auto-resume option shows an INFO for a few seconds allowing cancellation.
The manual requires periodic cleaning of the liquefier fins, checking hoses and connections for leaks and quality with replacement as needed, cleaning the hat-type strainer, and inspecting/replacing the heat transfer fluid. Refrigerant-circuit work (R-452A, R-23) must be performed by approved refrigeration contractors only.
Selection & Integration Q&A
Choose the P825 when the external loop has high pressure drop (flow-through reactors, semiconductor tools) and needs the high-discharge-pressure pump (67 l/min, 3 bar). The 815w is water-cooled and standard-pressure; pick it when cooling water is available and loop resistance is low.
Pump connections are M30x1.5 male with bore shape Y (60°) per DIN 3863. Hoses must use a ball socket per DIN 3863 and sleeve nut per DIN 3870; mismatched fittings risk leaks at 3 bar and 250 °C.
Base delivery includes cable but no plug; the drip tray, mating plug/hard-wiring, heat transfer fluid, hoses with DIN 3863/3870 fittings, and optional gas detection sensor/processing unit are not included. Scheduled tasks: condenser fin cleaning, hose inspection, strainer cleaning, fluid replacement.