Peter Huber Kältemaschinenbau Unistat P912w Dynamisches

Peter Huber Kältemaschinenbau Unistat P912w Dynamisches — Temperature control units with Noise level 65 dB.

The Unistat P912w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -90 to 250 °C. Its 6 kW heating capacity and 460 V 3~ 60 Hz supply distinguish it within the Unistat w series. It serves precise temperature control of externally closed or open applications in industrial processes.

Noise level
65 dB

Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection

Model Noise level, dBAmbient temperature limit, °CDisplay resolutionPower supplyPump connectionPump type
Unistat P912w Dynamisches Current 655–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat 1005w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 1015w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 705w Dynamisches —5–400, 01230V 1~ 50HzM24x1, 5 AG malePressure pump, variable
Unistat 815w Dynamisches 605–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malePressure pump, variable
Unistat 905w Dynamisches —5–400, 01 K208V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat 912w Dynamisches 655–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat 920w Dynamisches 715–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat 930w Dynamisches —5–400, 01460V 3~ 60HzM38x1, 5 AG malemagnetically coupled, st
Unistat 950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st
Unistat P815 Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P815w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825 Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P825w Dynamisches —5–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905 Dynamisches —5–350, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P905w Dynamisches —5–400, 01460V 3~ 60HzM30x1, 5 AG malemagnetically coupled, st
Unistat P915w Dynamisches 645–400, 01400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st
Unistat P920w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P925w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P930w Dynamisches —5–400, 01400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st
Unistat P950w Dynamisches —5–400, 01400V 3~ 50Hzflange DN40 PN10/40 EN10magnetically coupled, st

Full specifications

Core Performance & Functional Specifications
Noise level 65 dB(A)
Control output POKO ONE
Heating capacity 6 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range -90...250 °C
Dimensions, Weight & Mechanical Design
Weight 325 kg
Electrical, Power & Drive Specifications
Current consumption 20 A (max)
Power supply 460V 3~ 60Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Materials, Media & Process Compatibility
Maximum viscosity 50 mm²/s
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Cooling water connection G1/2 male
Cooling water consumption 516 l/h (at 15°C, flow 0°C)
Cooling water differential pressure 1 bar (min)
Cooling Water Pressure 6 bar (max)
Protection rating IP20
Standards, Safety & General Data
Safety class III / FL

Description

Construction and positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Electrical
Supply voltage and frequency tolerances are interdependent

The unit accepts ±5% voltage variation only with simultaneous ±2% frequency variation, and the combination of -5% voltage with +2% frequency is explicitly not allowed. Verify site power quality before connection to avoid damage or warranty issues.

Datasheet, page 2
Electrical
External branch circuit protection per UL 489 is mandatory

Leakage current exceeds 3.5 mA, so an external branch circuit protection device according to UL 489 must be installed. Three-phase devices under 63 A are supplied with cable but without plug; a suitable plug must be provided on site.

Datasheet, page 2
Cooling & Media
Cooling water pressure and temperature window must be respected

Cooling water differential pressure must be at least 1 bar and must not exceed 6 bar. Intake temperature must be between 5 °C and 20 °C; if water temperature can fall below the condensation point, insulate the cooling water pipes. Cooling capacity drops and flow demand may rise if water temperature exceeds 15 °C.

Datasheet, page 2
Process Limits
Expansion vessel locking depends on application type

For externally closed applications, the expansion vessel must remain unlocked; locking it will cause overpressure damage. For externally open applications, it must be locked to prevent fluid loss. Verify the application type before commissioning.

Operation Manual, page 33
Mounting
Leveling feet and parking brakes must be set before operation

Before commissioning, unscrew/activate the leveling feet and engage the parking brakes on casters (if present). Casters are not suitable for transport; use an industrial truck for moving the unit. Transport only in upright position and only when emptied.

Operation Manual, page 22
Maintenance
Shut off cooling water during short downtimes

Shut off the cooling water supply even for shorter downtimes such as overnight to prevent water damage and unnecessary load on the cooling water circuit. Periodically check hoses and connections for leaks and quality, and replace as needed.

Operation Manual, page 29
Control & I/O
Process Safety mode requires compressor permanently on

When Process Safety mode is enabled, the compressor must be set to Permanently ON so that maximum cooling capacity is released at the overtemperature trigger instead of switching off all poles. This mode is intended for exothermic reactions or critical processes.

Operation Manual, page 19

Selection & Integration Q&A

When should I choose the Unistat P912w over the smaller 815w or larger 1005w models?

Choose the P912w when its 6 kW heating capacity and -90 to 250 °C range fit your process, and when the 460 V 3~ 60 Hz supply is available. The 815w has lower noise (60 dB(A)) but likely less capacity; the 1005w and 1015w offer larger volumes. Select based on required heating/cooling power and space.

What are the requirements for connecting the cooling water circuit and the external application?

Cooling water connection is G1/2 male; supply must provide 1–6 bar differential pressure and 5–20 °C intake. Pump connection is M30x1.5 male with bore shape Y (60°) per DIN 3863; use ball socket per DIN 3863 and sleeve nut per DIN 3870 for pipework or hoses. Ensure heat transfer fluid viscosity ≤50 mm²/s.

What maintenance is required and what accessories are not included in the base delivery?

Periodically check hoses and connections for leaks and quality; replace as needed. Shut off cooling water during downtimes. The unit is supplied with cable but without a plug for three-phase power; a suitable plug must be provided on site. External branch circuit protection per UL 489 is required and not included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Unistat P912w Technical Data
Datasheet ·80,3 КБ ·3 pp.
View PDF
PDF
Unistat® Operation Manual — Unistat® 5, Unistat® Pilot ONE®
Manual ·3,6 МБ ·100 pp.
View PDF
PDF
Unistat Operation Manual
Manual ·3,7 МБ ·102 pp.
View PDF