Peter Huber Kältemaschinenbau Unistat P915w Dynamisches
Peter Huber Kältemaschinenbau Unistat P915w Dynamisches — Temperature control units with Noise level 64 dB.
The Unistat P915w Dynamisches is a water-cooled, free-standing temperature control unit with a magnetically coupled stainless-steel pump and Pilot ONE controller, covering -90 to 250 °C. It is the water-cooled 'w' variant of the 9xx series, distinguished from air-cooled siblings by its cooling-water circuit (G3/4 male, 720 l/h at 15 °C). It serves single-thermostat deep-freeze and high-temperature processes in externally closed or open circuits.
Peter Huber Kältemaschinenbau Unistat Series — Model Comparison & Selection
| Model | Noise level, dB | Ambient temperature limit, °C | Display resolution | Power supply | Pump connection | Pump type |
|---|---|---|---|---|---|---|
| Unistat P915w Dynamisches Current | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 1005w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 1015w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 705w Dynamisches | — | 5–40 | 0, 01 | 230V 1~ 50Hz | M24x1, 5 AG male | Pressure pump, variable |
| Unistat 815w Dynamisches | 60 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | Pressure pump, variable |
| Unistat 905w Dynamisches | — | 5–40 | 0, 01 K | 208V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 912w Dynamisches | 65 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 915w Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat 920w Dynamisches | 71 | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 930w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat 950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
| Unistat P815 Dynamisches | 64 | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P815w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825 Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P825w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905 Dynamisches | — | 5–35 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P905w Dynamisches | — | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P912w Dynamisches | 65 | 5–40 | 0, 01 | 460V 3~ 60Hz | M30x1, 5 AG male | magnetically coupled, st |
| Unistat P920w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P925w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P930w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st |
| Unistat P950w Dynamisches | — | 5–40 | 0, 01 | 400V 3~ 50Hz | flange DN40 PN10/40 EN10 | magnetically coupled, st |
Full specifications
| Noise level | 64 dB(A) |
| Control output | POKO ONE |
| Heating capacity | 6 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | -90...250 °C |
| Weight | 369 kg |
| Current consumption | 27 A (max.) |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Maximum viscosity | 50 mm²/s |
| Ambient temperature limit | 5...40 °C |
| Cooling water connection | G3/4 male |
| Cooling water consumption | 720 l/h (at 15°C, flow 0°C) |
| Cooling water differential pressure | 1 bar (min.) |
| Cooling Water Pressure | 6 bar (max.) |
| Protection rating | IP20 |
| Safety class | III / FL |
Description
Construction and series positioning
- Free-standing water-cooled unit (suffix 'w') with a 400 V 3~ 50 Hz supply, 27 A max current, IP20 protection, and 369 kg net weight.
- Magnetically coupled stainless-steel pump with adjustable speed, M30x1.5 male pump connection; external Pt100 sensor input.
- Pilot ONE controller with POKO ONE control output; interfaces Ethernet, USB (Host and Device), RS232.
- Within the Unistat 'Dynamisches' series, the P915w is the water-cooled 9xx frame; air-cooled siblings (e.g. Unistat 815w Dynamisches at 60 dB(A)) differ in condenser and acoustic profile.
Behavior across the temperature range
- Operating range -90...250 °C; cooling capacity is strongly temperature-dependent: 11 kW at 0 °C with ethanol versus 0.6 kW at -90 °C, so deep-cold loads must be sized at the cold end.
- Heating capacity 6 kW; display resolution 0.01 K; viscosity limit 50 mm²/s for the heat transfer fluid.
- Pump delivers up to 110 l/min and 3 bar max pressure, falling to 24 l/min at 2.5 bar; external circuit pressure drop must be matched to this curve.
- Minimum filling capacity 3.9 l with a 6.5 l expansion tank; expansion vessel must be unlocked for externally closed applications and locked for externally open (bath) applications.
Installation, control and operation
- Cooling water: G3/4 male connection, 5–20 °C intake, 720 l/h at 15 °C, differential pressure min. 1 bar / max. 6 bar; circuit materials include copper, stainless steel 1.4401, MS, PA, PPE, PTFE and EPDM.
- Electrical: three-phase devices below 63 A are delivered with cable but without plug; leakage current >3.5 mA requires proper earthing and RCD selection; voltage/frequency tolerances ±5 %/±2 %, with -5 % voltage plus +2 % frequency not allowed.
- Ambient 5...40 °C; sound pressure 64 dB(A); unit must be transported and stored upright and only moved when emptied; leveling feet/parking brakes activated before commissioning; ~2 h acclimation after cold/warm transfer.
- Pilot ONE offers Process Safety mode (compressor Permanently ON) and configurable power-failure response (Off/Standby or ON/Temperature control active).
Integration & Operating Notes
The water-cooled refrigeration circuit is designed for intake temperatures between 5 and 20 °C; supply pressure below 1 bar differential starves the condenser, while above 6 bar risks overpressuring the cooling circuit. Verify the site chilled-water supply and fit a pressure-reducing valve if necessary.
The unit draws up to 27 A on 400 V three-phase and requires 3x32 A fusing; three-phase devices below 63 A are delivered with cable but without a plug, so the customer must provide and fit the site plug. Leakage current exceeds 3.5 mA, so earthing and RCD selection must be engineered accordingly.
Cooling capacity collapses at low temperatures (0.6 kW at -90 °C versus 11 kW at 0 °C with ethanol), so heat loads for deep-freeze processes must be checked at the coldest operating point rather than at ambient. Oversizing expectations based on the 0 °C figure will lead to unachievable pull-down times.
The Pilot ONE can be set to 'Off/Standby' (default, temperature control started only by manual input) or 'ON/Temperature control active' (automatic restart after power restoration, with a brief INFO allowing cancellation). Select according to whether unattended restart is acceptable for the process; Process Safety mode additionally requires the compressor set to Permanently ON.
Selection & Integration Q&A
Choose the P915w when a chilled-water supply (5–20 °C, 1–6 bar differential) is available and the 9xx frame's capacity is needed; the 815w is air-cooled at 60 dB(A) and avoids water connections, while the 705w/1005w/1015w are smaller frames for lower loads.
Cooling water at 5–20 °C with G3/4 male connection, 720 l/h at 15 °C, and 1–6 bar differential; a 400 V 3~ 50 Hz supply fused at 3x32 A with a site-fitted plug (cable supplied without plug), plus earthing for >3.5 mA leakage current.
The site plug, drip tray, cooling-water hoses and connections, and heat transfer fluid are not included; periodic hose inspection/replacement, cooling-water shutoff for downtimes, and refrigerant-circuit work by approved contractors must be scheduled by the operator.